D Replacement Units

This appendix lists the replacement units for Recovery Appliance. It contains the following topics:

About Warranty Coverage

All replaceable parts are field replaceable units (FRUs) under the Oracle Premier Support for Systems warranty. Oracle field engineers install the replacement parts.

Understanding Repair Categories

Repair categories describe the potential impact of a repair action. Table D-1 describes the categories and actions.

Table D-1 Recovery Appliance Repair Categories

Category Description Examples

Hot Swap (HS)

Repair part is hot swappable, and can be replaced without shutting down the host system. Commands might be required before and after replacement to protect data.

  • Disks

  • Fans

  • Power supplies

Infrastructure Repair (IR)

Repairing a connectivity component within the Recovery Appliance rack. No downtime of the rack is required; however, individual components may require downtime.

  • Ethernet switch

  • External cables

  • InfiniBand switch

Compute Server Offline (DBO)

Repairing the part requires shutting down a compute server. No downtime of the rack is required; however, individual servers might require downtime, and they might be taken outside of the cluster temporarily.

If the server is currently running, then you must shut it down. See "Powering Down the Servers".

If you monitor the system using Oracle Enterprise Manager Grid Control, then avoid unnecessary alerts by putting the target in a blackout state. Refer to Oracle Enterprise Manager Administration for additional information.

  • Memory

  • PCIe cards

  • PDUs

  • Processors

  • System boards

Storage server Offline (EBO)

Repairing the part requires shutting down a storage server within the rack. No downtime of the rack is required; however, individual servers might require downtime, and they might be taken outside of the cluster temporarily. There also might be a temporary performance impact, while the system rebalances to maintain data redundancy.

If the server is currently running, then you must shut it down. See "Powering Down the Servers".

If you monitor the system using Oracle Enterprise Manager Grid Control, then avoid unnecessary alerts by putting the target in a blackout state. Refer to Oracle Enterprise Manager Administration for additional information.

  • Memory

  • PCIe cards

  • Processors

  • System boards

LED Status Descriptions

This section describes the LEDs.

Oracle Server LEDs

Table D-2 identifies the LED status indicators that can indicate faults on the compute servers and the storage servers.

Table D-2 Oracle Server LED Status Descriptions

Component LED Status

General Status

The following LEDs are located on the front and back panels of each server:

Service Required (amber)

Off indicates normal operation.

Steady on indicates a fault in the server.

Power/OK (green)

Steady on indicates that the server is powered on.

A slow blink indicates that the server is starting up.

A steady blink indicates that standby power is on, but chassis power is off.

Off indicates no AC power or an incomplete startup of Oracle ILOM.

Fans

Each fan module has one bicolored LED, which you can see when the top cover fan door is open.

Fan Status (amber/green)

Amber indicates that the fan module is faulty. The front and rear panel Service Required LEDs are also lit when the system detects a fan module fault.

Green indicates that the system is powered on, and the fan module is functioning correctly.

Drives

The following LEDs are located on the storage and boot drives:

Service Required (amber)

Off indicates normal operation.

Steady on indicates a fault in the drive.

OK/Activity (green)

Steady on indicates normal inactivity.

A steady blink indicates normal activity.

Off indicates that the power is off, or the system does not recognize the drive.

Power supply

The following LEDs are on each power supply. You can see them from the back of the server.

Service Required (amber)

Off indicates normal operation.

Steady on indicates that the system has detected a problem in the power supply regarding the voltage, current, temperature, or fans.

AC OK/DC OK (green)

Steady on indicates normal operation for both AC and DC power.

A slow blink indicates that input AC power is normal and output DC power is disabled.

Off indicates no input AC power.

See Also:

Sun Datacenter InfiniBand Switch 36 LEDs

Table D-3 identifies the LED status indicators that can indicate faults on Sun Datacenter InfiniBand Switch 36.

Table D-3 Sun InfiniBand Switch LED Status Descriptions

Component LED Status

Chassis

The following LEDs are located on the left side of the rear panel.

Attention (amber)

Steady on indicates a fault.

Off indicates normal operation.

Flashing indicates no function.

OK (green)

Steady on indicates normal operation.

Off indicates that the switch is off or initializing.

Flashing indicates no function.

Link status

The link status LEDs are located by the data cable connectors on the rear panel.

Link (green)

Steady on indicates that a link is established.

Off indicates that the link is down.

Flashing indicates that there are symbol errors.

Network management ports

The following LEDs are located on the network management connector on the rear panel.

Link Speed (amber/green):

Green steady on indicates a 1000BASE-T link.

Amber steady on indicates a 100BASE-T link.

Off indicates no link.

Flashing indicates no function.

Activity (green):

Flashing indicates packet activity.

On indicates no function.

Off indicates no activity.

Power supply

The following LEDs are located on the power supply at the front of the chassis.

Attention (amber)

Steady on indicates a fault, and 12 VDC is shut down.

Off indicates normal operation.

Flashing indicates no function.

OK (green)

Steady on indicates 12 VDC.

Off indicates no DC voltage.

Flashing indicates no function.

AC LED is green

Steady on indicates AC power is supplied.

Off indicates that AC power is not present.

Flashing indicates no function.

Fan

The following LED is located on the air inlet on the front of the chassis.

FT

On indicates a problem with the fan.

Off indicates normal operation

See Also:

"Identifying LEDs" in the Sun Datacenter InfiniBand Switch 36 Service Manual at

http://docs.oracle.com/cd/E26698_01/html/E26434/z40000fe1394411.html

Parts for Compute Servers

The following topics identify the replacement parts for the Recovery Appliance compute servers:

Oracle Server X7 Oracle Database Server Parts

The following image shows the front view of Oracle Server X7 Oracle Database Server.

Figure D-1 Front View of Oracle Server X7 Oracle Database Server

Description of Figure D-1 follows
Description of "Figure D-1 Front View of Oracle Server X7 Oracle Database Server"

The following image shows the rear view of Oracle Server.

Figure D-2 Rear View of X7 Oracle Database Server

Description of Figure D-2 follows
Description of "Figure D-2 Rear View of X7 Oracle Database Server"

The following table lists the replaceable parts for X7 Oracle Server. Refer to this table only if you have a basic warranty. All replacement parts shown in the following table are considered FRU when covered under Premier Support of Systems warranty.

Table D-4 Replacement Parts for Oracle Server X7 Oracle Database Servers

Part Number Description Repair Category Coverage under Basic Warranty Repair Procedure

350-1719

Assembly, slim-rail, 1U - 2U, snap in

DBO

CRU

  1. If the server is currently running, then it should be shut down gracefully. See "Stopping Recovery Appliance Services" for additional information.

  2. See "Reinstall the Server Into the Rack" in Oracle Server X7-2 Service Manual at http://docs.oracle.com/cd/E72435_01/html/E72445/gqrpu.html#scrolltoc

370-5621

3 volt lithium battery

DBO

FRU

See "Servicing the Battery (CRU)" in Oracle Server X7-2 Service Manual at http://docs.oracle.com/cd/E72435_01/html/E72445/gqviw.html#scrolltoc

7093015

Drive, 600 GB 10K, SAS2, SFF

DBO

FRU

See "Servicing Storage Drives (CRU)" in Oracle Server X7-2 Service Manual at http://docs.oracle.com/cd/E72435_01/html/E72445/gquak.html#scrolltoc

7322171

Cable, interlock, 125 mm

DBO

FRU

See "Servicing Other Cables" in Oracle Server X7-2 Service Manual at http://docs.oracle.com/cd/E72435_01/html/E72445/gqvev.html#scrolltoc

7046442

Assembly, Dual 40Gb/Sec (4x) QDR InfiniBand Host Channel Adapter Module M3

DBO

CRU

  1. If the server is currently running, then it should be shut down gracefully. See "Stopping Recovery Appliance Services" for additional information.

  2. See "Servicing PCIe Cards (CRU)" in Oracle Server X7-2 Service Manual at http://docs.oracle.com/cd/E72435_01/html/E72445/gqvjk.html#scrolltoc

  3. See "Configuring the InfiniBand Switches"

7051223

Assembly, Dual 25 GbE SFP28 LP, X8 PCIe 3.0, RoHS:Y

DBO

CRU

  1. If the server is currently running, then it should be shut down gracefully. See "Stopping Recovery Appliance Services" for additional information.

  2. See "Servicing PCIe Cards (CRU)" in Oracle Server X7-2 Service Manual at http://docs.oracle.com/cd/E72435_01/html/E72445/gqvjk.html#scrolltoc

7328735

Heat sink, CPU 1U

DBO

FRU

See "Servicing Processors (FRU)" in Oracle Server X7-2 Service Manual at http://docs.oracle.com/cd/E72435_01/html/E72445/gqtmk.html#scrolltoc

7343599

Assembly, riser, 1-slot, 1U

DBO

FRU

See "Servicing PCIe Risers (CRU)" in Oracle Server X7-2 Service Manual at http://docs.oracle.com/cd/E72435_01/html/E72445/gqvft.html#scrolltoc

7330698

DIMM, 32 GB, RDIMM, DDR4, 2666

DBO

CRU

See "Servicing the DIMMs (CRU)" in Oracle Server X7-2 Service Manual at http://docs.oracle.com/cd/E72435_01/html/E72445/gqvkr.html#scrolltoc

7333459

Power supply, AC, A266, F, 12V, 1200W

HS

CRU

  1. Remove rear left side of the CMA, and then swing it back and out to the right.

    The telescopic cross member supporting the cables directly behind the server can be retracted to access both power supplies.

  2. See "Servicing Power Supplies (CRU)" in Oracle Server X7-2 Service Manual at http://docs.oracle.com/cd/E72435_01/html/E72445/gqunc.html#scrolltoc

  3. Replace the CMA.

7332895

HBA, 12 Gb SAS PCIe 16-port RAID internal with flash module

DBO

FRU

See "Servicing the Internal HBA Card and HBA Super Capacitor (FRU)" in Oracle Server X7-2 Service Manual at http://docs.oracle.com/cd/E72435_01/html/E72445/gqvmq.html#scrolltoc

7086345

Assembly, super cap, 13.5 volt, 6.4F, SAS3 HBA

DBO

FRU

See "Servicing the Internal HBA Card and HBA Super Capacitor (FRU)" in Oracle Server X7-2 Service Manual at http://docs.oracle.com/cd/E72435_01/html/E72445/gqvmq.html#scrolltoc

7340897

Cable, SAS3 to HBA

DBO

CRU

See "Servicing the Internal HBA Cables" in Oracle Server X7-2 Service Manual at http://docs.oracle.com/cd/E72435_01/html/E72445/gqvav.html#scrolltoc

7331123

Quad fan module

HS

CRU

See "Servicing Fan Modules (CRU)" in Oracle Server X7-2 Service Manual at http://docs.oracle.com/cd/E72435_01/html/E72445/gquhg.html#scrolltoc

7095106

CPU, P-8160, 2.1 GHz, 150W, 24 core, (SR3B0)

DBO

FRU

See "Servicing Processors (FRU)" in Oracle Server X7-2 Service Manual at http://docs.oracle.com/cd/E72435_01/html/E72445/gqtmk.html#scrolltoc

7341145

Assembly, 8-slot disk backplane SAS3, 1U

DBO

FRU

See "Servicing the Disk Backplane (FRU)" in Oracle Server X7-2 Service Manual at http://docs.oracle.com/cd/E72435_01/html/E72445/gqvap.html#scrolltoc

7317636

Assembly, motherboard, 1U

DBO

FRU

  1. See "Servicing the Motherboard (FRU)" in Oracle Server X7-2 Service Manual at http://docs.oracle.com/cd/E72435_01/html/E72445/gqvfa.html#scrolltoc

  2. Press F2 after restarting the server.

  3. Set the boot order.

         

Oracle Server X6-2 and X5-2 Parts

Figure D-3 shows the front view of the Oracle Server X6-2 or X5-2.

Figure D-3 Front View of Oracle Server X6-2 or X5-2

Description of Figure D-3 follows
Description of "Figure D-3 Front View of Oracle Server X6-2 or X5-2"

Figure D-4 shows the rear view of the Oracle Server X6-2 or X5-2.

Figure D-4 Rear View of Oracle Server X6-2 or X5-2

Description of Figure D-4 follows
Description of "Figure D-4 Rear View of Oracle Server X6-2 or X5-2"

Table D-5 lists the replaceable parts for Oracle Server X6-2 compute servers. Unless otherwise noted, the repair procedures are in Oracle Server X6-2 Service Manual.

Note:

All replacement parts listed in the following table are FRUs when covered under the Premier Support of Systems warranty.

Table D-5 Replacement Parts for Oracle Server X6-2 Compute Servers

Part Number Description Repair Category Repair Procedure

350-1719

Assembly, slim rail, 1U - 2U, snap in

DBO

  1. If the server is running, then shut it down gracefully. See "Shutting Down Recovery Appliance".

  2. See "Reinstall the Server Into the Rack" at

    http://docs.oracle.com/cd/E62159_01/html/E62171/z40004191003899.html

370-5621

3 volt lithium battery

DBO

See "Servicing the Battery (CRU)" at

http://docs.oracle.com/cd/E62159_01/html/E62171/z40003f01423753.html

542-0287

Drive, 600 GB 10K, SAS2, SFF

DBO

See "Servicing Storage Drives (CRU)" at

http://docs.oracle.com/cd/E62159_01/html/E62171/z40000091011460.html

7014226

Cable, interlock, 125 mm

DBO

See "Servicing the Power, FIM, Disk Backplane Data, and DVD Cables" at

http://docs.oracle.com/cd/E62159_01/html/E62171/gnyov.html

7046442

Assembly, dual port, QDR CX3, host channel adapter

DBO

  1. If the server is running, then shut it down gracefully. See "Shutting Down Recovery Appliance".

  2. See "Servicing PCIe Cards" at

    http://docs.oracle.com/cd/E62159_01/html/E62171/z40000f91037409.html

  3. Check the InfiniBand configuration. See "Verifying InfiniBand Network Configuration" at

    http://docs.oracle.com/cd/E50790_01/doc/doc.121/e51951/components.htm#DBMMN21155

  4. Use the following command to verify that the new hardware conforms to the hardware and firmware requirements:

    /opt/oracle.SupportTools/CheckHWnFWprofile

7051223

Assembly, Dual 10 GbE SFP+LP, X8 PCIe 2.0, RoHS:Y

DBO

See Sun Dual 10GbE SFP+ PCIe 2.0 Low Profile Adapter User's Guide at

http://docs.oracle.com/cd/E19407-01/820-7898-11/index.html

See "Servicing PCIe Cards (CRU)" at

http://docs.oracle.com/cd/E62159_01/html/E62171/z40000f91037409.html

7067728

Heat sink, CPU 1U

DBO

See "Servicing Processors (FRU)" at

http://docs.oracle.com/cd/E62159_01/html/E62171/z40001d31037480.html

7077680

Assembly, riser, 2S, 1U

DBO

See "Servicing PCIe Risers (CRU)" at

http://docs.oracle.com/cd/E62159_01/html/E62171/z40000f91037394.html

7078072

DIMM, 32 GB, RDIMM, DDR4, 2400

DBO

See "Servicing the DIMMs (CRU)" at

http://docs.oracle.com/cd/E62159_01/html/E62171/z40003f01425075.html

7079395

Power supply, AC, A256, F, 12V, 600W

HS

  1. Remove the rear left side of the CMA, and then swing the CMA back and out to the right.

    To access both power supplies, retract the telescopic cross member supporting the cables directly behind the server.

  2. See "Servicing the Power Supplies (CRU)" at

    http://docs.oracle.com/cd/E62159_01/html/E62171/z40000091014153.html

  3. Replace the CMA.

7081071

Assembly, riser, single stack, 1U

DBO

See "Servicing PCIe Risers (CRU)" at

http://docs.oracle.com/cd/E62159_01/html/E62171/z40000f91037394.html

7085209

HBA, 12 Gb SAS PCIe 8-port RAID internal with flash module

DBO

See "Servicing the Internal HBA Card (FRU)" at

http://docs.oracle.com/cd/E62159_01/html/E62171/goeht.html

7086345

Assembly, super cap, 13.5 volt, 6.4F, SAS3 HBA

DBO

See "Servicing the Internal HBA Card (FRU)" at

http://docs.oracle.com/cd/E62159_01/html/E62171/goeht.html

7086346

Cable, super cap, 620M, 6-pin, straight, SAS3 HBA

DBO

See "Servicing the Internal HBA SAS Cable assembly" at

http://docs.oracle.com/cd/E62159_01/html/E62171/z40003eb1420346.html

7089073

Fan module

HS

See "Servicing Fan Modules (CRU)" at

http://docs.oracle.com/cd/E62159_01/html/E62171/z40000091014194.html

7095106

CPU, E5-2699 v4, 2.2 GHz, 145W, 22 core, C-1 (SR1XD)

DBO

See "Servicing Processors (FRU)" at

http://docs.oracle.com/cd/E62159_01/html/E62171/z40001d31037480.html

7097205

Assembly, 8DBP, 1U/2U

DBO

See "Servicing the Disk Backplane (FRU)" at

http://docs.oracle.com/cd/E62159_01/html/E62171/z40011771417642.html

7098505

Assembly, motherboard, 1U

DBO

  1. See "Servicing the Motherboard (FRU)" at

    http://docs.oracle.com/cd/E62159_01/html/E62171/z40011771418436.html

  2. Press F2 after restarting the server.

  3. Set the boot order.

Table D-6 lists the replaceable parts for Oracle Server X5-2 compute servers. Unless otherwise noted, the repair procedures are in Oracle Server X5-2 Service Manual.

Note:

All replacement parts listed in the following table are FRUs when covered under the Premier Support of Systems warranty.

Table D-6 Replacement Parts for Oracle Server X5-2 Compute Servers

Part Number Description Repair Category Repair Procedure

350-1719

Assembly, slim rail, 1U - 2U, snap in

DBO

  1. If the server is running, then shut it down gracefully. See "Shutting Down Recovery Appliance".

  2. See "Reinstall the Server Into the Rack" at

    http://docs.oracle.com/cd/E41059_01/html/E48320/z40004191003899.html

370-5621

3 volt lithium battery

DBO

See "Servicing the Battery" at

http://docs.oracle.com/cd/E41059_01/html/E48320/z40003f01423753.html

542-0287

Drive, 600 GB 10K, SAS2, SFF

DBO

See "Servicing Storage Drives (CRU)" at

http://docs.oracle.com/cd/E41059_01/html/E48320/z40000091011460.html

7014226

Cable, interlock, 125 mm

DBO

See "Servicing the Power, FIM, Disk Backplane Data, and DVD Cables" at

http://docs.oracle.com/cd/E41059_01/html/E48320/gnyov.html

7046442

Assembly, dual port, QDR CX3, host channel adapter

DBO

  1. If the server is running, then shut it down gracefully. See "Shutting Down Recovery Appliance".

  2. See "Servicing PCIe Cards (CRU)" at

    http://docs.oracle.com/cd/E41059_01/html/E48320/z40000f91037409.html

  3. Check the InfiniBand configuration. See "Verifying InfiniBand Network Configuration" at

    http://docs.oracle.com/cd/E50790_01/doc/doc.121/e51951/components.htm#DBMMN21155

  4. Use the following command to verify that the new hardware conforms to the hardware and firmware requirements:

    /opt/oracle.SupportTools/CheckHWnFWprofile

7051223

Assembly, Dual 10 GbE SFP+LP, X8 PCIe 2.0, RoHS:Y

DBO

See Sun Dual 10GbE SFP+ PCIe 2.0 Low Profile Adapter User's Guide at

http://docs.oracle.com/cd/E19407-01/820-7898-11/index.html

See "Servicing PCIe Cards (CRU)" at

http://docs.oracle.com/cd/E41059_01/html/E48320/z40000f91037409.html

7067728

Heat sink, CPU 1U

DBO

See "Servicing Processors (FRU)" at

http://docs.oracle.com/cd/E41059_01/html/E48320/z40001d31037480.html

7077680

Assembly, riser, 2S, 1U

DBO

See "Servicing PCIe Risers (CRU)" at

http://docs.oracle.com/cd/E41059_01/html/E48320/z40000f91037394.html

7078072

DIMM, 32 GB, LRDIMM, DDR4, 2133

DBO

See "Servicing the DIMMs (CRU)" at

http://docs.oracle.com/cd/E41059_01/html/E48320/z40003f01425075.html

7079395

Power supply, AC, A256, F, 12V, 600W

HS

  1. Remove the rear left side of the CMA, and then swing the CMA back and out to the right.

    To access both power supplies, retract the telescopic cross member supporting the cables directly behind the server.

  2. See "Servicing Power Supplies (CRU)" at

    http://docs.oracle.com/cd/E41059_01/html/E48320/z40000091014153.html

  3. Replace the CMA.

7081071

Assembly, riser, single stack, 1U

DBO

See "Servicing PCIe Risers (CRU)" at

http://docs.oracle.com/cd/E41059_01/html/E48320/z40000f91037394.html

7085209

HBA, 12 Gb SAS PCIe 8-port RAID internal with flash module

DBO

See "Servicing the Internal HBA Card (FRU)" at

http://docs.oracle.com/cd/E41059_01/html/E48320/goeht.html

7086345

Assembly, super cap, 13.5 volt, 6.4F, SAS3 HBA

DBO

See "Servicing the Internal HBA Card (FRU)" at

http://docs.oracle.com/cd/E41059_01/html/E48320/goeht.html

7086346

Cable, super cap, 620M, 6-pin, straight, SAS3 HBA

DBO

See "Servicing the Internal HBA SAS Cable assembly" at

http://docs.oracle.com/cd/E41059_01/html/E48320/z40003eb1420346.html

7089073

Fan module

HS

See "Servicing Fan Modules (CRU)" at

http://docs.oracle.com/cd/E41059_01/html/E48320/z40000091014194.html

7095106

CPU, E5-2699 v3, 2.3 GHz, 145W, 18 core, C-1 (SR1XD)

DBO

See "Servicing Processors (FRU)" at

http://docs.oracle.com/cd/E41059_01/html/E48320/z40001d31037480.html

7097205

Assembly, 8DBP, 1U/2U

DBO

See "Servicing the Disk Backplane (FRU)" at

http://docs.oracle.com/cd/E41059_01/html/E48320/z40011771417642.html

7098505

Assembly, motherboard, 1U

DBO

  1. See "Servicing the Motherboard (FRU)" at

    http://docs.oracle.com/cd/E41059_01/html/E48320/z40011771418436.html

  2. Press F2 after restarting the server.

  3. Set the boot order.

Sun Server X4-2 Parts

Figure D-5 shows the front view of the Sun Server X4-2.

Figure D-5 Front View of Sun Server X4-2

Description of Figure D-5 follows
Description of "Figure D-5 Front View of Sun Server X4-2"

Figure D-6 shows the rear view of the Sun Server X4-2.

Figure D-6 Rear View of Sun Server X4-2

Description of Figure D-6 follows
Description of "Figure D-6 Rear View of Sun Server X4-2"

Table D-7 lists the replaceable parts for Sun Server X4-2 compute servers. Unless otherwise noted, the repair procedures are in Sun Server X4-2 Service Manual.

Note:

All replacement parts listed in the following table are FRUs when covered under the Premier Support of Systems warranty.

Table D-7 Replacement Parts for Sun Server X4-2 Compute Servers

Part Number Description Repair Category Repair Procedure

7013526

Fan module

HS

See "Servicing Fan Modules" in Sun Server X4-2 Service Manual at

http://docs.oracle.com/cd/E36975_01/html/E38045/z40000091014194.html#scrolltoc

7018701

DIMM, 16 GB, DDR3, 2RX4, 1600, 1.35 V

DBO

See "Servicing the DIMMs" at

http://docs.oracle.com/cd/E36975_01/html/E38045/z40003f01425075.html#scrolltoc

7020774

Heat sink, CPU 1U, 60 mm FIN

DBO

See "Servicing Storage Drives (CRU)" at

http://docs.oracle.com/cd/E36975_01/html/E38045/z40000091011460.html#scrolltoc

7023303

Dual 16 Gigabit/Sec Fiber Channel / 10 GbS FCoE Host Adapter, QLogic

See "Install a PCIe Card in PCIe Slot 1 or 2" at

http://docs.oracle.com/cd/E36975_01/html/E38045/z40007611438967.html#scrolltoc

7027478

Disk Backplane, RoHS:Y

DBO

See "Servicing the Disk Backplane (FRU)" at

http://docs.oracle.com/cd/E36975_01/html/E38045/z40011771417642.html#scrolltoc

7039841

Front indicator module

DBO

See "Servicing PCIe Risers" at

http://docs.oracle.com/cd/E36975_01/html/E38045/z40011771417642.html#scrolltoc

7046442

Assembly, dual port, QDR CX3, host channel adapter

DBO

  1. If the server is currently running, then shut it down. See "Powering Down the Servers".

  2. See "Servicing PCIe Cards" at

    http://docs.oracle.com/cd/E36975_01/html/E38045/z40000f91037409.html#scrolltoc

  3. See "Connecting Recovery Appliance to Your Networks".

  4. Use the following command to verify that the new hardware meets the hardware and firmware requirements:

    /opt/oracle.SupportTools/CheckHWnFWprofile

7047503

Assembly, 6 GB, SAS RAID disk PCIe HBA, RoHS:Y

DBO

See "Servicing Storage Drives" at

http://docs.oracle.com/cd/E36975_01/html/E38045/z40000091011460.html#scrolltoc

7048707

Assembly, riser, double stack

DBO

See "Servicing PCIe Risers" at

http://docs.oracle.com/cd/E36975_01/html/E38045/z40011771417642.html#scrolltoc

7048710

1-slot PCI Express riser assembly

DBO

See "Servicing PCIe Risers" at

http://docs.oracle.com/cd/E36975_01/html/E38045/z40011771417642.html#scrolltoc

7051223

Assembly, Dual 10 GbE SFP+LP, X8 PCIe 2.0, RoHS:Y

DBO

See Sun Dual 10GbE SFP+ PCIe 2.0 Low Profile Adapter User's Guide at

http://docs.oracle.com/cd/E19407-01/820-7898-11/index.html

7057184

Assembly, battery carrier remote

HS

"Replacing a Disk Controller BBU on a Compute Server"

7058153

Assembly, motherboard, X4-2

DBO

  1. See "Servicing the Motherboard" at

    http://docs.oracle.com/cd/E36975_01/html/E38045/z40011771418436.html#scrolltoc

  2. Press F2 after restarting the server.

  3. Set the boot order.

7060020

Universal upgrade remote battery kit

EBO

"Replacing a Disk Controller BBU on a Compute Server"

7060951

Power supply, AC, A256, F, 12V, 600W

HS

  1. Remove rear left side of the CMA, and then swing the CMA back and out to the right.

    To access both power supplies, retract the telescopic cross member supporting the cables directly behind the server.

  2. See "Servicing the Power Supply" at

    http://docs.oracle.com/cd/E36975_01/html/E38045/z40000091014153.html#scrolltoc

  3. Replace the CMA.

7069232

CPU, E5-2697 v2, 12-core, 2.7 GHz

DBO

See "Servicing Processors" at

http://docs.oracle.com/cd/E36975_01/html/E38045/z40001d31037480.html#scrolltoc

See Also:

Sun Server X4-2 Service Animations at

http://docs.oracle.com/cd/E36975_01/html/E49470/index.html

Parts for Storage Servers

The following topics identify the replacement parts for the Recovery Appliance storage servers:

Oracle Exadata Storage Server X7-2 High Capacity Server Parts

The following figure shows the front view of the Oracle Exadata Storage Server X7-2 High Capacity Server.

Figure D-7 Front View of Oracle Exadata Storage Server X7-2 High Capacity Server


Description of Figure D-7 follows
Description of "Figure D-7 Front View of Oracle Exadata Storage Server X7-2 High Capacity Server "

The following figure shows the rear view of the Oracle Exadata Storage Server X7-2 High Capacity Server.

Figure D-8 Rear View of Oracle Exadata Storage Server X7-2 High Capacity Server


Description of Figure D-8 follows
Description of "Figure D-8 Rear View of Oracle Exadata Storage Server X7-2 High Capacity Server"

The following table lists the replaceable parts for Oracle Exadata Storage Server X7-2 High Capacity Servers. Refer to this table only if you have a basic warranty. All replacement parts shown in the following table are considered FRU when covered under Premier Support of Systems warranty.

Table D-8 Replacement Parts for Oracle Exadata Storage Server X7-2 High Capacity Servers

Part Number Description Repair Category Coverage under Basic Warranty Repair Procedure

350-1719

Assembly, 1U-2U Snap-in, slim rail rack

EBO

CRU

  1. If the server is currently running, then it should be shut down gracefully. See "Stopping Recovery Appliance Services" for additional information.

  2. See "Reinstall the Server Into the Rack" in Oracle Exadata Storage Server X7-2 EF and HC Service Manual at http://docs.oracle.com/cd/E72463_01/html/E72479/gqqca.html#scrolltoc

370-5621

3 volt lithium battery

EBO

FRU

See "Servicing the Battery" in Oracle Exadata Storage Server X7-2 EF and HC Service Manual at http://docs.oracle.com/cd/E72463_01/html/E72479/gqtff.html#scrolltoc

7322171

Indicator assembly, LFIM

EBO

FRU

See "Servicing the Front LED Indicator Module" in Oracle Exadata Storage Server X7-2 EF and HC Service Manual at http://docs.oracle.com/cd/E72463_01/html/E72479/gqtpg.html#scrolltoc

7341141

12-slot disk backplane assembly

EBO

FRU

See "Servicing the Disk Backplane" in Oracle Exadata Storage Server X7-2 EF and HC Service Manual at http://docs.oracle.com/cd/E72463_01/html/E72479/gqtsb.html#scrolltoc

7333459

Power Supply, A266, 1200W, AC Input

HS

FRU

  1. Remove rear left side of the CMA, and then swing it back and out to the right.

    The telescopic cross member supporting the cables directly behind the server can be retracted to access both power supplies.

  2. See "Servicing Power Supplies" in Oracle Exadata Storage Server X7-2 EF and HC Service Manual at http://docs.oracle.com/cd/E72463_01/html/E72479/gqtag.html#scrolltoc

  3. Replace the CMA.

7322166

Fan assembly, 2U

HS

FRU

See "Servicing Fan Modules" in Oracle Exadata Storage Server X7-2 EF and HC Service Manual at http://docs.oracle.com/cd/E72463_01/html/E72479/gqtak.html#scrolltoc

7046442

Assembly, dual 40Gb/Sec (4x) QDR InfiniBand Host Channel Adapter Module M3

EBO

FRU

  1. If the server is currently running, then it should be shut down gracefully. See "Stopping Recovery Appliance Services" for additional information.

  2. See "Servicing PCIe Cards" in Oracle Exadata Storage Server X7-2 EF and HC Service Manual at http://docs.oracle.com/cd/E72463_01/html/E72479/gqtcq.html#scrolltoc

  3. See "Configuring the InfiniBand Switches"

  4. Verify the new hardware meets the hardware and firmware specifications using the following command:

    /opt/oracle.SupportTools/CheckHWnFWprofile

7322160

Heat sink, CPU

EBO

FRU

See "Servicing Processors (FRU)" in Oracle Exadata Storage Server X7-2 EF and HC Service Manual at http://docs.oracle.com/cd/E72463_01/html/E72479/gqtmk.html#scrolltoc

7332759

Assembly, drive, 10 TB, 3.5 inch, SAS/7200rpm

HS

FRU

See "Servicing Storage Drives" in Oracle Exadata Storage Server X7-2 EF and HC Service Manual at http://docs.oracle.com/cd/E72463_01/html/E72479/gqtcs.html#scrolltoc

7330697

DIMM, 16 GB, RDIMM, DDR4, 2666

EBO

FRU

See "Servicing the DIMMS" in Oracle Exadata Storage Server X7-2 EF and HC Service Manual at http://docs.oracle.com/cd/E72463_01/html/E72479/gqtcm.html#scrolltoc

7332895

HBA, 12 Gbps SAS PCIe 16-port internal RAID with flash module

EBO

FRU

See "Servicing an Internal HBA Card and HBA Super Capacitor" in Oracle Exadata Storage Server X7-2 EF and HC Service Manual at http://docs.oracle.com/cd/E72463_01/html/E72479/gqtjv.html#scrolltoc

7086345

HBA Assembly, super cap, 13.5V, 6.4F, SAS3 HBA

EBO

FRU

See "Servicing an Internal HBA Card and HBA Super Capacitor" in Oracle Exadata Storage Server X7-2 EF and HC Service Manual at http://docs.oracle.com/cd/E72463_01/html/E72479/gqtjv.html#scrolltoc

7315464

SAS-3 Data Cable Assembly

EBO

FRU

See "Servicing SAS Cables" in Oracle Exadata Storage Server X7-2 EF and HC Service Manual at http://docs.oracle.com/cd/E72463_01/html/E72479/gqthb.html#scrolltoc

7341587

M.2,150GB,SATA,22x80mm,SSD,INTEL, DC S3520

EBO

FRU

See "Servicing the Internal M.2 Flash SSDs" in Oracle Exadata Storage Server X7-2 EF and HC Service Manual at http://docs.oracle.com/cd/E72463_01/html/E72479/grlly.html#scrolltoc

7335943

6.4TB Flash Accelerator F640 NVMe Card

EBO

FRU

See "Servicing PCIe Cards" in Oracle Exadata Storage Server X7-2 EF and HC Service Manual at http://docs.oracle.com/cd/E72463_01/html/E72479/gqtcq.html#scrolltoc

7347511

CPU, XEON S-4114 , 2.2G, 85W, 10 CORE, (SR3GK)

EBO

FRU

See "Servicing Processors (FRU)" in Oracle Exadata Storage Server X7-2 EF and HC Service Manual at http://docs.oracle.com/cd/E72463_01/html/E72479/gqtmk.html#scrolltoc

7335280

System board assembly

EBO

FRU

See "Servicing the Motherboard Assembly" in Oracle Exadata Storage Server X7-2 EF and HC Service Manual at http://docs.oracle.com/cd/E72463_01/html/E72479/gqtwc.html#scrolltoc

         

Oracle Server X6-2L and X5-2L Parts

Figure D-9 shows the front view of the Oracle Server X6-2L or X5-2L. The hard drives are numbered from left to right, starting in the lower left. The drives in the bottom row are numbers 0, 1, 2, and 3. The drives in the middle row are numbers 4, 5, 6, and 7. The drives in the top row are numbers 8, 9, 10, and 11.

Figure D-9 Front View of Oracle Server X6-2L or X5-2L

Description of Figure D-9 follows
Description of "Figure D-9 Front View of Oracle Server X6-2L or X5-2L"

Figure D-10 shows the rear view of an Oracle Server X6-2L or X5-2L storage server.

Figure D-10 Rear View of Oracle Server X6-2L or X5-2L

Description of Figure D-10 follows
Description of "Figure D-10 Rear View of Oracle Server X6-2L or X5-2L"

Table D-9 lists the replaceable parts for the Oracle Server X6-2L. Unless otherwise noted, the repair procedures are in Oracle Server X6-2L Service Manual.

Note:

All replacement parts listed in the following table are FRUs when covered under Premier Support of Systems warranty.

Table D-9 Replacement Parts for Oracle Server X6-2L Storage Servers

Part Number Description Repair Category Repair Procedure

350-1719

Assembly, 1U-2U Snap-in, slim rail rack

EBO

  1. If the server is currently running, then shut it down gracefully. See "Shutting Down Recovery Appliance".

  2. See "Reinstall the Server in the Rack" at

    http://docs.oracle.com/cd/E62172_01/html/E62184/z40004191003899.html

370-5621

3 volt lithium battery

EBO

See "Servicing the Battery (CRU)" at

http://docs.oracle.com/cd/E62172_01/html/E62184/z40000f91037456.html

7014226

Cable, interlock, 125 mm

EBO

See "Servicing SAS Cables (FRU)" at

http://docs.oracle.com/cd/E62172_01/html/E62184/baecfjbc.html

7017231

Indicator assembly, right

EBO

See "Servicing the Front LED/USB Indicator Modules (FRU)" at

http://docs.oracle.com/cd/E62172_01/html/E62184/z40001d31014236.html

7023515

Disk backplane assembly, 2 rear

EBO

See "Servicing the Front and Rear Storage Drive Backplanes (FRU)" at

http://docs.oracle.com/cd/E62172_01/html/E62184/z40007ac1419009.html

7044130

Power Supply, A258, 1000W, AC Input

HS

  1. Remove the rear left side of the CMA, and then swing the CMA back and out to the right.

    To access both power supplies, retract the telescopic cross member supporting the cables directly behind the server.

  2. See "Servicing Power Supplies (CRU)" at

    http://docs.oracle.com/cd/E62172_01/html/E62184/z40000091014153.html

  3. Replace the CMA.

7045042

Fan assembly, 2U, 80 x 80, Ferrite, center rotate

HS

See "Servicing Fan Modules (CRU)" at

http://docs.oracle.com/cd/E62172_01/html/E62184/z40000091014194.html

7046442

Assembly, dual port, QDR CX3, host channel adapter

EBO

  1. If the server is running, then shut it down gracefully. See "Shutting Down Recovery Appliance".

  2. See "Servicing PCIe Cards (CRU)" at

    http://docs.oracle.com/cd/E62172_01/html/E62184/z40000f91037409.html

  3. Use the following command to verify that the new hardware meets the hardware and firmware requirements:

    /opt/oracle.SupportTools/CheckHWnFWprofile 

7064884

Heat sink, CPU

EBO

See "Servicing Processors (FRU)" at

http://docs.oracle.com/cd/E62172_01/html/E62184/z40001d31037480.html

7066824

Assembly, drive, 8 TB, 3.5 inch, SAS/7200rpm

HS

See "Servicing Storage Drives and Rear Drives (CRU)" at

http://docs.oracle.com/cd/E62172_01/html/E62184/z40000091011460.html

7069337

Assembly, backplane, 12X3.5, W/SAS expansion, 2U

EBO

See "Servicing the Front and Rear Storage Drive Backplanes (FRU)" at

http://docs.oracle.com/cd/E62172_01/html/E62184/z40007ac1419009.html

7078070

DIMM, 16 GB, RDIMM, DDR4, 2400

EBO

See "Servicing the DIMMS (CRU)" at

http://docs.oracle.com/cd/E62172_01/html/E62184/ceicjagi.html

7085209

HBA, 12 Gb SAS PCIe 8-port RAID internal with flash module

EBO

See "Servicing the Oracle Storage 12 Gb/s SAS PCIe RAID HBA Card (FRU)" at

http://docs.oracle.com/cd/E62172_01/html/E62184/gocfy.html

7086345

Assembly, super cap, 13.5 volt, 6.4F, SAS3 HBA

EBO

See "Servicing the Oracle Storage 12 Gb/s SAS PCIe RAID HBA Card (FRU)" at

http://docs.oracle.com/cd/E62172_01/html/E62184/gocfy.html

7086346

Cable, super cap, 620M, 6-pin, straight, SAS3 HBA

EBO

See "Servicing SAS Cables (FRU)" at

http://docs.oracle.com/cd/E62172_01/html/E62184/baecfjbc.html

7090170

Flash drive, MLC, OSA ID, USB, 8 GB

EBO

See "Servicing the Internal USB Flash Drives (CRU)" at

http://docs.oracle.com/cd/E62172_01/html/E62184/ceiicfbd.html

7090698

Assembly, 3.2 TB eMLC flash F320 NVMe card

EBO

See Oracle Flash Accelerator F320 PCIe Card User Guide at

http://docs.oracle.com/cd/E65386_01/html/E65387/goiip.html

7095102

CPU, E5-2630 V4, 2.2 G, 85 W, 10 CORE, R-2 (SR206)

EBO

See "Servicing Processors (FRU)" at

http://docs.oracle.com/cd/E62172_01/html/E62184/z40001d31037480.html

7096185

Assembly, indicator, left

EBO

See "Servicing the Front LED/USB Indicator Modules (FRU)" at

http://docs.oracle.com/cd/E62172_01/html/E62184/z40001d31014236.html

7098504

ASM, MOBO tray

EBO

Table D-10 lists the replaceable parts for the Oracle Server X5-2L. Unless otherwise noted, the repair procedures are in Oracle Server X5-2L Service Manual.

Note:

All replacement parts listed in the following table are FRUs when covered under Premier Support of Systems warranty.

Table D-10 Replacement Parts for Oracle Server X5-2L Storage Servers

Part Number Description Repair Category Repair Procedure

350-1719

Assembly, 1U-2U Snap-in, slim rail rack

EBO

  1. If the server is currently running, then shut it down gracefully. See "Shutting Down Recovery Appliance".

  2. See "Reinstall the Server in the Rack" at

    http://docs.oracle.com/cd/E41033_01/html/E48333/z40004191003899.html

370-5621

3 volt lithium battery

EBO

See "Servicing the Battery (CRU)" at

http://docs.oracle.com/cd/E41033_01/html/E48333/z40000f91037456.html

7014226

Cable, interlock, 125 mm

EBO

See "Servicing SAS Cables (FRU)" at

http://docs.oracle.com/cd/E41033_01/html/E48333/baecfjbc.html

7017231

Indicator assembly, right

EBO

See "Servicing the Front LED/USB Indicator Modules (FRU)" at

http://docs.oracle.com/cd/E41033_01/html/E48333/z40001d31014236.html

7023515

Disk backplane assembly, 2 rear

EBO

See "Servicing the Front and Rear Storage Drive Backplanes (FRU)" at

http://docs.oracle.com/cd/E41033_01/html/E48333/z40007ac1419009.html

7044130

Power Supply, A258, 1000W, AC Input

HS

  1. Remove the rear left side of the CMA, and then swing the CMA back and out to the right.

    To access both power supplies, retract the telescopic cross member supporting the cables directly behind the server.

  2. See "Servicing Power Supplies (CRU)" at

    http://docs.oracle.com/cd/E41033_01/html/E48333/z40000091014153.html

  3. Replace the CMA.

7045042

Fan assembly, 2U, 80 x 80, Ferrite, center rotate

HS

See "Servicing Fan Modules (CRU)" at

http://docs.oracle.com/cd/E41033_01/html/E48333/z40000091014194.html

7046442

Assembly, dual port, QDR CX3, host channel adapter

EBO

  1. If the server is running, then shut it down gracefully. See "Shutting Down Recovery Appliance".

  2. See "Servicing PCIe Cards (CRU)" at

    http://docs.oracle.com/cd/E41033_01/html/E48333/z40000f91037409.html

  3. Use the following command to verify that the new hardware meets the hardware and firmware requirements:

    /opt/oracle.SupportTools/CheckHWnFWprofile 

7064884

Heat sink, CPU

EBO

See "Servicing Processors (FRU)" at

http://docs.oracle.com/cd/E41033_01/html/E48333/z40001d31037480.html

7066824

Assembly, drive, 4 TB, 3.5 inch, SAS/7200rpm

HS

See "Servicing Storage Drives and Rear Drives (CRU)" at

http://docs.oracle.com/cd/E41033_01/html/E48333/z40000091011460.html

7069337

Assembly, backplane, 12X3.5, W/SAS expansion, 2U

EBO

See "Servicing the Front and Rear Storage Drive Backplanes (FRU)" at

http://docs.oracle.com/cd/E41033_01/html/E48333/z40007ac1419009.html

7078070

DIMM, 8 GB, RDIMM, DDR4, 2133

EBO

See "Servicing the DIMMS (CRU)" at

http://docs.oracle.com/cd/E41033_01/html/E48333/ceicjagi.html

7085209

HBA, 12 Gb SAS PCIe 8-port RAID internal with flash module

EBO

See "Servicing the Oracle Storage 12 Gb/s SAS PCIe RAID HBA Card (FRU)" at

http://docs.oracle.com/cd/E41033_01/html/E48333/gocfy.html

7086345

Assembly, super cap, 13.5 volt, 6.4F, SAS3 HBA

EBO

See "Servicing the Oracle Storage 12 Gb/s SAS PCIe RAID HBA Card (FRU)" at

http://docs.oracle.com/cd/E41033_01/html/E48333/gocfy.html

7086346

Cable, super cap, 620M, 6-pin, straight, SAS3 HBA

EBO

See "Servicing SAS Cables (FRU)" at

http://docs.oracle.com/cd/E41033_01/html/E48333/baecfjbc.html

7090170

Flash drive, MLC, OSA ID, USB, 8 GB

EBO

See "Servicing the Internal USB Flash Drives (CRU)" at

http://docs.oracle.com/cd/E41033_01/html/E48333/ceiicfbd.html

7090698

Assembly, 1.6 TB eMLC flash F160 NVMe card, Aura 3.0 with LP BRKT

EBO

See Oracle Flash Accelerator F160 PCIe Card User Guide at

http://docs.oracle.com/cd/E54943_01/html/E54947/index.html

7095102

CPU, E5-2630 V3, 2.4G, 85W, 8 CORE, R-2 (SR206)

EBO

See "Servicing Processors (FRU)" at

http://docs.oracle.com/cd/E41033_01/html/E48333/z40001d31037480.html

7096185

Assembly, indicator, left

EBO

See "Servicing the Front LED/USB Indicator Modules (FRU)" at

http://docs.oracle.com/cd/E41033_01/html/E48333/z40001d31014236.html

7098504

ASM, MOBO tray

EBO

Sun Server X4-2L Parts

Figure D-11 shows the front view of the Sun Server X4-2L. The hard drives are numbered from left to right, starting in the lower left. The drives in the bottom row are numbers 0, 1, 2, and 3. The drives in the middle row are numbers 4, 5, 6, and 7. The drives in the top row are numbers 8, 9, 10, and 11.

Figure D-11 Front View of Sun Server X4-2L

Description of Figure D-11 follows
Description of "Figure D-11 Front View of Sun Server X4-2L"

Figure D-12 shows the rear view of a Sun Server X4-2L storage server.

Figure D-12 Rear View of Sun Server X4-2L

Description of Figure D-12 follows
Description of "Figure D-12 Rear View of Sun Server X4-2L"

Table D-11 lists the replaceable parts for the Sun Server X4-2L. Unless otherwise noted, the repair procedures are in Sun Server X4-2L Service Manual.

Note:

All replacement parts listed in the following table are FRUs when covered under Premier Support of Systems warranty.

Table D-11 Replacement Parts for Sun Server X4-2L Storage Servers

Part Number Description Repair Category Repair Procedure

371-5002

USB drive, 4 GB

EBO

See "Servicing the Internal USB Flash Drives" in Sun Server X4-2L Service Manual at

http://docs.oracle.com/cd/E36974_01/html/E38145/ceiicfbd.html#scrolltoc

7014226

Cable, interlock, 125 mm

EBO

See "Servicing Cables" at

http://docs.oracle.com/cd/E36974_01/html/E38145/baecfjbc.html#scrolltoc

7014391

Expander assembly, 2U

EBO

See "Servicing the SAS Expander Module" at

http://docs.oracle.com/cd/E36974_01/html/E38145/ceieidja.html#scrolltoc

7017231

Indicator assembly, right

EBO

See "Servicing the Front LED/USB Indicator Modules" at

http://docs.oracle.com/cd/E36974_01/html/E38145/z40001d31014236.html#scrolltoc

7018701

DIMM, 16 GB, DDR3, 1600, 2Rx4, 1.35V

EBO

See "Servicing the DIMMS" at

http://docs.oracle.com/cd/E36974_01/html/E38145/ceicjagi.html#scrolltoc

7020486

DIMM, 8 GB, DDR3, 1600, 2Rx4, 1.35V

EBO

See "Servicing the DIMMs" at

http://docs.oracle.com/cd/E36974_01/html/E38145/ceicjagi.html#scrolltoc

7020776

Heatsink, CPU, 2U, 60 MM FIN, RoHS:YU

EBO

See "Servicing Storage Drives and Rear Drives" at

http://docs.oracle.com/cd/E36974_01/html/E38145/z40000091011460.html#scrolltoc

7023515

Disk backplane assembly, 2 rear

EBO

See "Servicing the Front and Rear Storage Drive Backplanes" at

http://docs.oracle.com/cd/E36974_01/html/E38145/z40007ac1419009.html#scrolltoc

7027479

Disk backplane assembly, 4-Slot 3.5" RoHS:Y

EBO

See "Servicing the Front and Rear Storage Drive Backplanes" at

http://docs.oracle.com/cd/E36974_01/html/E38145/z40007ac1419009.html#scrolltoc

7044130

Power Supply, A258, 1000 Watt AC Input

HS

  1. Remove rear left side of the CMA, and then swing the CMA back and out to the right.

    To access both power supplies, retract the telescopic cross member supporting the cables directly behind the server.

  2. See "Servicing Power Supplies" at

    http://docs.oracle.com/cd/E36974_01/html/E38145/z40000091014153.html#scrolltoc

  3. Replace the CMA.

7045042

Fan assembly, 2U, 80 x 80, Ferrite, center_rotate

HS

See "Servicing Fan Modules" at

http://docs.oracle.com/cd/E36974_01/html/E38145/z40000091014194.html#scrolltoc

7046442

Assembly, dual port, QDR CX3, host channel adapter

EBO

  1. If the server is currently running, then shut it down. See "Powering Down the Servers".

  2. See "Servicing PCIe Cards" at

    http://docs.oracle.com/cd/E36974_01/html/E38145/z40000f91037409.html#scrolltoc

  3. See "Connecting Recovery Appliance to Your Networks".

  4. Use the following command to verify that the new hardware meets the hardware and firmware requirements:

    /opt/oracle.SupportTools/CheckHWnFWprofile 

7047503

Assembly, 6 GB, SAS RAID disk PCIe HBA, RoHS:Y

DBO

See "Servicing Storage Drives and Rear Drives" at

http://docs.oracle.com/cd/E36974_01/html/E38145/z40000091011460.html#scrolltoc

7048864

Indicator assembly, left, 2U

EBO

See "Servicing the Front LED/USB Indicator Modules (FRU)" at

http://docs.oracle.com/cd/E36974_01/html/E38145/z40001d31014236.html#scrolltoc

7057184

Assembly, battery carrier remote

HS

"Replacing a Disk Controller BBU on a Storage Server"

7058152

Assembly, motherboard, X4-2L

EBO

See "Servicing the Motherboard Assembly" at

http://docs.oracle.com/cd/E36974_01/html/E38145/z40001d31037512.html#scrolltoc

7060020

Universal upgrade remote battery kit

EBO

"Replacing a Disk Controller BBU on a Storage Server"

7069200

Assembly, 800 GB eMLC flash PCIe card

EBO

See "Servicing PCIe Cards" at

http://docs.oracle.com/cd/E36974_01/html/E38145/z40000f91037409.html#scrolltoc

7069242

CPU, E5-2630 v2, 6-core, 2.6 Ghz

EBO

See "Servicing Processors" at

http://docs.oracle.com/cd/E36974_01/html/E38145/z40001d31037480.html#scrolltoc

7070656

Disk assembly, 1.2 TB, SAS2

HS

See "Servicing Storage Drives and Rear Drives" at

http://docs.oracle.com/cd/E36974_01/html/E38145/z40000091011460.html#scrolltoc

7106353

4 TB 7200 rpm SAS HDD with bracket

DBO

See "Servicing Storage Drives and Rear Drives" at

http://docs.oracle.com/cd/E36974_01/html/E38145/z40000091011460.html#scrolltoc

Parts for InfiniBand Switches

Table D-12 lists the replaceable parts for the InfiniBand switches used in Recovery Appliance. See "Cables and Cable Accessories for Recovery Appliance" for information about InfiniBand cables.

Note:

All replacement parts listed in the following table are FRUs when covered under Premier Support of Systems warranty.

Table D-12 Replacement Parts for InfiniBand Switches

Part Number Description Repair Category Repair

300-2143

760 watt power supply, RoHS:Y

HS

See Sun Datacenter InfiniBand Switch 36 User's Guide at

http://docs.oracle.com/cd/E19197-01/835-0784-05/gentextid-226.html

300-2299

760 watt AC input power supply

HS

See Sun Datacenter InfiniBand Switch 36 User's Guide at

http://docs.oracle.com/cd/E19197-01/835-0784-05/gentextid-226.html

350-1312

Fan module for Sun Datacenter InfiniBand Switch 36, RoHS:Y

HS

See Sun Datacenter InfiniBand Switch 36 User's Guide at

http://docs.oracle.com/cd/E19197-01/835-0784-05/gentextid-226.html

350-1566

Fan module, 1 RU, Sanace, reverse

HS

See Sun Datacenter InfiniBand Switch 36 User's Guide at

http://docs.oracle.com/cd/E19197-01/835-0784-05/gentextid-226.html

371-2210

CR2032 3 v battery, RoHS:Y

IR

See Sun Datacenter InfiniBand Switch 36 User's Guide at

http://docs.oracle.com/cd/E19197-01/835-0784-05/gentextid-226.html

541-3495

Sun Datacenter InfiniBand Switch 36, RoHS:YL

IR

See Sun Datacenter InfiniBand Switch 36 User's Guide at

http://docs.oracle.com/cd/E19197-01/835-0784-05/gentextid-226.html

7052970

Sun Datacenter InfiniBand Switch 36, RoHS:YL

IR

See Sun Datacenter InfiniBand Switch 36 User's Guide at

http://docs.oracle.com/cd/E19197-01/835-0784-05/gentextid-226.html

7061031

Fan module, 1 RU, Sanace, reverse

HS

See Sun Datacenter InfiniBand Switch 36 User's Guide at

http://docs.oracle.com/cd/E19197-01/835-0784-05/gentextid-226.html

Parts for Cisco Switch

Table D-13 lists replaceable parts for the Cisco switch used with Recovery Appliance.

Note:

All replacement parts listed in the following table are FRUs when covered under Premier Support of Systems warranty.

Table D-13 Replacement Parts for Cisco Switch

Part Number Description Repair Category Repair

7023685

Cisco Catalyst 4948 switch, RoHS:Y

IR

See chapter 3 in Catalyst 4948E and Catalyst 4948E-F Switch Installation Guide at http://www.cisco.com/c/en/us/td/docs/switches/lan/catalyst4900/4948E/installation/guide/4948E_ins.html

7024423

Power supply for Cisco Catalyst 4948 switch, RoHS:Y

HS

See chapter 4 in Catalyst 4948E and Catalyst 4948E-F Switch Installation Guide at http://www.cisco.com/c/en/us/td/docs/switches/lan/catalyst4900/4948E/installation/guide/4948E_ins.html

7024424

Cooling fan for Cisco Catalyst 4948 switch, RoHS:Y

HS

See chapter 4 in Catalyst 4948E and Catalyst 4948E-F Switch Installation Guide at http://www.cisco.com/c/en/us/td/docs/switches/lan/catalyst4900/4948E/installation/guide/4948E_ins.html

Parts for Power Distribution Units

Table D-14 lists the replacement parts for the power distribution units (PDUs). Given the number of cables and connections, Oracle recommends that you shut down the Recovery Appliance rack when replacing power distribution unit parts.

Note:

All replacement parts listed in the following table are FRUs when covered under Premier Support of Systems warranty.

Table D-14 Replacement Parts for Power Distribution Units

Part Number Description Repair Category Repair

180-2379

13A/250V 90 degree IEC 320 Sheet E to IEC 320 C13 cord, 1 meter, RoHS:Y

HS

Not applicable

180-2380

13A/250V 90 degree IEC 320 Sheet E to IEC 320 C13 cord, 2 meter, RoHS:Y

HS

Not applicable

371-4000

Three-phase PDU: 15kV,5-Pin, IEC309 32A, 5 PIN 230/400V, 3ph IP44, International, RoHS:Y

IR

See "Replacing a Power Distribution Unit" of this guide.

371-4199

Single-phase PDU: 15kVA, with three 30A/250V 2-Pole/3-Wire NEMA L6-30P Plugs, North America, RoHS:Y

IR

See "Replacing a Power Distribution Unit" of this guide.

371-4201

Single-phase PDU: 15kVA, with three Blue 32A/240V Splash-proof 2-Pole/3-Wire IEC 60309 Plugs, International, RoHS:Y

IR

See "Replacing a Power Distribution Unit" of this guide.

371-5039

Single-phase PDU: 22k VA Hubbell CS8265C PlugNo X-Option

IR

See "Replacing a Power Distribution Unit" of this guide.

371-5040

Single-phase PDU: 22k VA Blue 32A IEC 60309 Plug No X-Option

IR

See "Replacing a Power Distribution Unit" of this guide.

7051908

Three-phase PDU: 15kVA, IEC309 60A, 4 PIN, 250VAC, 3ph IP67, North America, RoHS:Y

IR

See "Replacing a Power Distribution Unit" of this guide.

Cables and Cable Accessories for Recovery Appliance

Table D-15 lists the replacement cables and cable accessories for Recovery Appliance.

Note:

All replacement parts listed in the following table are FRUs when covered under Premier Support of Systems warranty.

Table D-15 Replacement Cables for Recovery Appliance

Part Number Description Repair Category Repair

350-1287

Slim rail, CMA, 1U-2U for a storage server

EBO

  1. If the server is currently running, then it should be shut down gracefully. See "Powering On and Off a Recovery Appliance Rack" for additional information.

  2. See "Installing the Cable Management Arm" in Sun Fire X4170, X4270, and X4275 Servers Installation Manual at

    http://docs.oracle.com/cd/E19477-01/820-5827-13/rack_install.html#50614309_99582

350-1546

Cable management arm (CMA) 1U, RoHS:Y for compute server

DBO

  1. If the server is currently running, then it should be shut down gracefully. See "Powering On and Off a Recovery Appliance Rack" for additional information.

  2. See "Installing the Cable Management Arm" in Sun Fire X4170, X4270, and X4275 Servers Installation Manual at

    http://docs.oracle.com/cd/E19477-01/820-5827-13/rack_install.html#50614309_99582

350-1519

Serial cable kit, RoHS:Y with the following:

  • USB to DB 9-pin M serial cable

  • DB 9-pin F to DB 9-pin F null modem cable

HS

See Sun Datacenter InfiniBand Switch 36 User's Guide at

http://docs.oracle.com/cd/E19197-01/835-0784-05/gentextid-226.html

350-1637

Label assembly, EV2, 2-way, upgrade, label

HS

See In-Rack Cabling Tables for Recovery Appliance X4

350-1638

Label assembly EV2, 3-way, service upgrade, label

HS

See In-Rack Cabling Tables for Recovery Appliance X4

350-1639

Label assembly EV2, 4-way, service upgrade, label

HS

See In-Rack Cabling Tables for Recovery Appliance X4

350-1640

Label assembly EV2, 5-way, service upgrade, label

HS

See In-Rack Cabling Tables for Recovery Appliance X4

350-1641

Label assembly EV2, 6-way, service upgrade, label

HS

See In-Rack Cabling Tables for Recovery Appliance X4

350-1642

Label assembly EV2, 7-way, service upgrade, label

HS

See In-Rack Cabling Tables for Recovery Appliance X4

350-1643

Label assembly EV2, 8-way, service upgrade, label

HS

See In-Rack Cabling Tables for Recovery Appliance X4

530-4445

QSFP InfiniBand passive copper cable, 10 GbE, 3 m, RoHS:Y

HS

See Sun Datacenter InfiniBand Switch 36 User's Guide at

http://docs.oracle.com/cd/E19197-01/835-0784-05/gentextid-226.html

Note: There is a loss of redundancy when replacing cables.

530-4446

QSFP InfiniBand passive copper cable, 10 GbE, 5 m, RoHS:Y

HS

See Sun Datacenter InfiniBand Switch 36 User's Guide at

http://docs.oracle.com/cd/E19197-01/835-0784-05/gentextid-226.html

Note: There is a loss of redundancy when replacing cables.

530-4403

4x QSFP copper QDR InfiniBand cable, 2 m, RoHS:Y

HS

See Sun Datacenter InfiniBand Switch 36 User's Guide at

http://docs.oracle.com/cd/E19197-01/835-0784-05/gentextid-226.html

Note: There is a loss of redundancy when replacing cables.

530-4404

4x QSFP copper QDR InfiniBand cable, 3 m, RoHS:Y

HS

See Sun Datacenter InfiniBand Switch 36 User's Guide at

http://docs.oracle.com/cd/E19197-01/835-0784-05/gentextid-226.html

530-4415

4x QSFP copper QDR InfiniBand cable, 5 m, RoHS:Y

HS

See Sun Datacenter InfiniBand Switch 36 User's Guide at

http://docs.oracle.com/cd/E19197-01/835-0784-05/gentextid-226.html

530-4432

Ethernet cable, Cat 5/5E, RJ45 to RJ45, 7 foot, blue, RoHS:Y

HS

See Catalyst 4948E and Catalyst 4948E-F Switch Installation Guide at http://www.cisco.com/c/en/us/td/docs/switches/lan/catalyst4900/4948E/installation/guide/4948E_ins.html

530-4433

Ethernet cable, Cat 5/5E, RJ45 to RJ45, 10 foot, red, RoHS:Y

HS

See Catalyst 4948E and Catalyst 4948E-F Switch Installation Guide at http://www.cisco.com/c/en/us/td/docs/switches/lan/catalyst4900/4948E/installation/guide/4948E_ins.html

530-4434

Ethernet cable, Cat 5/5E, RJ45 to RJ45, 7 foot, red, RoHS:Y

HS

See Catalyst 4948E and Catalyst 4948E-F Switch Installation Guide at http://www.cisco.com/c/en/us/td/docs/switches/lan/catalyst4900/4948E/installation/guide/4948E_ins.html

530-4435

Ethernet cable, Cat 5/5E, RJ45 to RJ45, 10 foot, black, RoHS:Y

HS

See Catalyst 4948E and Catalyst 4948E-F Switch Installation Guide at http://www.cisco.com/c/en/us/td/docs/switches/lan/catalyst4900/4948E/installation/guide/4948E_ins.html

530-4436

Ethernet cable, Cat 5/5E, RJ45 to RJ45, 7 foot, black, RoHS:Y

HS

See Catalyst 4948E and Catalyst 4948E-F Switch Installation Guide at http://www.cisco.com/c/en/us/td/docs/switches/lan/catalyst4900/4948E/installation/guide/4948E_ins.html

530-4437

Ethernet cable, Cat 5/5E, RJ45 to RJ45, 7 foot, orange, RoHS:Y

HS

See Catalyst 4948E and Catalyst 4948E-F Switch Installation Guide at http://www.cisco.com/c/en/us/td/docs/switches/lan/catalyst4900/4948E/installation/guide/4948E_ins.html

530-4438

Ethernet cable, Cat 5/5E, RJ45 to RJ45, 10 foot, black, RoHS:Y

HS

See Catalyst 4948E and Catalyst 4948E-F Switch Installation Guide at http://www.cisco.com/c/en/us/td/docs/switches/lan/catalyst4900/4948E/installation/guide/4948E_ins.html

530-4444

QSFP to QSFP Passive Copper Cable, 1 m, RoHS:Y

HS

See Sun Datacenter InfiniBand Switch 36 User's Guide at

http://docs.oracle.com/cd/E19197-01/835-0784-05/gentextid-226.html

530-4445

QSFP passive copper cable, 10 GE, 3 m

HS

See Sun Datacenter InfiniBand Switch 36 User's Guide at

http://docs.oracle.com/cd/E19197-01/835-0784-05/gentextid-226.html

530-4502-01

Ethernet cable, Cat 5/5E, 10 foot, blue, RoHS:Y

HS

See Catalyst 4948E and Catalyst 4948E-F Switch Installation Guide at http://www.cisco.com/c/en/us/td/docs/switches/lan/catalyst4900/4948E/installation/guide/4948E_ins.html

7015400

Power cable, jumper, SR2, 2m C14RA, 10A, C13

HS

See "Replacing a Power Distribution Unit" of this guide.

7042273

Slim rail, cable management arm, 1U-2U for a storage server

EBO

  1. If the server is currently running, then shut it down. See "Shutting Down Recovery Appliance".

  2. See "Installing the Second-Generation Cable Management Arm" in Sun Server X4-2L Service Manual at

    http://docs.oracle.com/cd/E36974_01/html/E38145/z40000151427029.html#scrolltoc

7102869

Passive fiber InfiniBand cable, 10 m, RoHS:Y

HS

  1. See Sun Datacenter InfiniBand Switch 36 User's Guide at

    http://docs.oracle.com/cd/E19197-01/835-0784-05/gentextid-226.html

Note: Purchase two QSFP SR Transceivers (Part Number X2124A-N) for each passive fiber cable.

7102870

Passive fiber InfiniBand cable, 20 m, RoHS:Y

HS

See Sun Datacenter InfiniBand Switch 36 User's Guide at

http://docs.oracle.com/cd/E19197-01/835-0784-05/gentextid-226.html

Note: Purchase two QSFP SR Transceivers (Part Number X2124A-N) for each passive fiber cable.

7102871

Passive fiber InfiniBand cable, 50 m, RoHS:Y

HS

See Sun Datacenter InfiniBand Switch 36 User's Guide at

http://docs.oracle.com/cd/E19197-01/835-0784-05/gentextid-226.html

Note: Purchase two QSFP SR Transceivers (Part Number X2124A-N) for each passive fiber cable.