D Replacement Units
This appendix lists the replacement units for Recovery Appliance. It contains the following topics:
About Warranty Coverage
All replaceable parts are field replaceable units (FRUs) under the Oracle Premier Support for Systems warranty. Oracle field engineers install the replacement parts.
Understanding Repair Categories
Repair categories describe the potential impact of a repair action. Table D-1 describes the categories and actions.
Table D-1 Recovery Appliance Repair Categories
Category | Description | Examples |
---|---|---|
Hot Swap (HS) |
Repair part is hot swappable, and can be replaced without shutting down the host system. Commands might be required before and after replacement to protect data. |
|
Infrastructure Repair (IR) |
Repairing a connectivity component within the Recovery Appliance rack. No downtime of the rack is required; however, individual components may require downtime. |
|
Compute Server Offline (DBO) |
Repairing the part requires shutting down a compute server. No downtime of the rack is required; however, individual servers might require downtime, and they might be taken outside of the cluster temporarily. If the server is currently running, then you must shut it down. See "Powering Down the Servers". If you monitor the system using Oracle Enterprise Manager Grid Control, then avoid unnecessary alerts by putting the target in a blackout state. Refer to Oracle Enterprise Manager Administration for additional information. |
|
Storage server Offline (EBO) |
Repairing the part requires shutting down a storage server within the rack. No downtime of the rack is required; however, individual servers might require downtime, and they might be taken outside of the cluster temporarily. There also might be a temporary performance impact, while the system rebalances to maintain data redundancy. If the server is currently running, then you must shut it down. See "Powering Down the Servers". If you monitor the system using Oracle Enterprise Manager Grid Control, then avoid unnecessary alerts by putting the target in a blackout state. Refer to Oracle Enterprise Manager Administration for additional information. |
|
LED Status Descriptions
Oracle Server LEDs
Table D-2 identifies the LED status indicators that can indicate faults on the compute servers and the storage servers.
Table D-2 Oracle Server LED Status Descriptions
See Also:
-
"About Server and Component Status Indicators" in the Sun Server X4-2 Service Manual at
http://docs.oracle.com/cd/E36975_01/html/E38045/z4000be71405942.html#scrolltoc
-
"About Server and Component Status Indicators" in the Sun Server X4-2L Service Manual at
http://docs.oracle.com/cd/E36974_01/html/E38145/z40003ec1405942.html#scrolltoc
Sun Datacenter InfiniBand Switch 36 LEDs
Table D-3 identifies the LED status indicators that can indicate faults on Sun Datacenter InfiniBand Switch 36.
Table D-3 Sun InfiniBand Switch LED Status Descriptions
See Also:
"Identifying LEDs" in the Sun Datacenter InfiniBand Switch 36 Service Manual at
http://docs.oracle.com/cd/E26698_01/html/E26434/z40000fe1394411.html
Parts for Compute Servers
The following topics identify the replacement parts for the Recovery Appliance compute servers:
Oracle Server X7 Oracle Database Server Parts
The following image shows the front view of Oracle Server X7 Oracle Database Server.
Figure D-1 Front View of Oracle Server X7 Oracle Database Server
Description of "Figure D-1 Front View of Oracle Server X7 Oracle Database Server"
The following image shows the rear view of Oracle Server.
Figure D-2 Rear View of X7 Oracle Database Server
Description of "Figure D-2 Rear View of X7 Oracle Database Server"
The following table lists the replaceable parts for X7 Oracle Server. Refer to this table only if you have a basic warranty. All replacement parts shown in the following table are considered FRU when covered under Premier Support of Systems warranty.
Table D-4 Replacement Parts for Oracle Server X7 Oracle Database Servers
Part Number | Description | Repair Category | Coverage under Basic Warranty | Repair Procedure |
---|---|---|---|---|
350-1719 |
Assembly, slim-rail, 1U - 2U, snap in |
DBO |
CRU |
|
370-5621 |
3 volt lithium battery |
DBO |
FRU |
See "Servicing the Battery (CRU)" in Oracle Server X7-2 Service Manual at |
7093015 |
Drive, 600 GB 10K, SAS2, SFF |
DBO |
FRU |
See "Servicing Storage Drives (CRU)" in Oracle Server X7-2 Service Manual at |
7322171 |
Cable, interlock, 125 mm |
DBO |
FRU |
See "Servicing Other Cables" in Oracle Server X7-2 Service Manual at |
7046442 |
Assembly, Dual 40Gb/Sec (4x) QDR InfiniBand Host Channel Adapter Module M3 |
DBO |
CRU |
|
7051223 |
Assembly, Dual 25 GbE SFP28 LP, X8 PCIe 3.0, RoHS:Y |
DBO |
CRU |
|
7328735 |
Heat sink, CPU 1U |
DBO |
FRU |
See "Servicing Processors (FRU)" in Oracle Server X7-2 Service Manual at |
7343599 |
Assembly, riser, 1-slot, 1U |
DBO |
FRU |
See "Servicing PCIe Risers (CRU)" in Oracle Server X7-2 Service Manual at |
7330698 |
DIMM, 32 GB, RDIMM, DDR4, 2666 |
DBO |
CRU |
See "Servicing the DIMMs (CRU)" in Oracle Server X7-2 Service Manual at |
7333459 |
Power supply, AC, A266, F, 12V, 1200W |
HS |
CRU |
|
7332895 |
HBA, 12 Gb SAS PCIe 16-port RAID internal with flash module |
DBO |
FRU |
See "Servicing the Internal HBA Card and HBA Super Capacitor (FRU)" in Oracle Server X7-2 Service Manual at |
7086345 |
Assembly, super cap, 13.5 volt, 6.4F, SAS3 HBA |
DBO |
FRU |
See "Servicing the Internal HBA Card and HBA Super Capacitor (FRU)" in Oracle Server X7-2 Service Manual at |
7340897 |
Cable, SAS3 to HBA |
DBO |
CRU |
See "Servicing the Internal HBA Cables" in Oracle Server X7-2 Service Manual at |
7331123 |
Quad fan module |
HS |
CRU |
See "Servicing Fan Modules (CRU)" in Oracle Server X7-2 Service Manual at |
7095106 |
CPU, P-8160, 2.1 GHz, 150W, 24 core, (SR3B0) |
DBO |
FRU |
See "Servicing Processors (FRU)" in Oracle Server X7-2 Service Manual at |
7341145 |
Assembly, 8-slot disk backplane SAS3, 1U |
DBO |
FRU |
See "Servicing the Disk Backplane (FRU)" in Oracle Server X7-2 Service Manual at |
7317636 |
Assembly, motherboard, 1U |
DBO |
FRU |
|
Oracle Server X6-2 and X5-2 Parts
Figure D-3 shows the front view of the Oracle Server X6-2 or X5-2.
Figure D-3 Front View of Oracle Server X6-2 or X5-2
Description of "Figure D-3 Front View of Oracle Server X6-2 or X5-2"
Figure D-4 shows the rear view of the Oracle Server X6-2 or X5-2.
Figure D-4 Rear View of Oracle Server X6-2 or X5-2
Description of "Figure D-4 Rear View of Oracle Server X6-2 or X5-2"
Table D-5 lists the replaceable parts for Oracle Server X6-2 compute servers. Unless otherwise noted, the repair procedures are in Oracle Server X6-2 Service Manual.
Note:
All replacement parts listed in the following table are FRUs when covered under the Premier Support of Systems warranty.
Table D-5 Replacement Parts for Oracle Server X6-2 Compute Servers
Part Number | Description | Repair Category | Repair Procedure |
---|---|---|---|
350-1719 |
Assembly, slim rail, 1U - 2U, snap in |
DBO |
|
370-5621 |
3 volt lithium battery |
DBO |
See "Servicing the Battery (CRU)" at
|
542-0287 |
Drive, 600 GB 10K, SAS2, SFF |
DBO |
See "Servicing Storage Drives (CRU)" at
|
7014226 |
Cable, interlock, 125 mm |
DBO |
See "Servicing the Power, FIM, Disk Backplane Data, and DVD Cables" at |
7046442 |
Assembly, dual port, QDR CX3, host channel adapter |
DBO |
|
7051223 |
Assembly, Dual 10 GbE SFP+LP, X8 PCIe 2.0, RoHS:Y |
DBO |
See Sun Dual 10GbE SFP+ PCIe 2.0 Low Profile Adapter User's Guide at
See "Servicing PCIe Cards (CRU)" at
|
7067728 |
Heat sink, CPU 1U |
DBO |
See "Servicing Processors (FRU)" at
|
7077680 |
Assembly, riser, 2S, 1U |
DBO |
See "Servicing PCIe Risers (CRU)" at
|
7078072 |
DIMM, 32 GB, RDIMM, DDR4, 2400 |
DBO |
See "Servicing the DIMMs (CRU)" at
|
7079395 |
Power supply, AC, A256, F, 12V, 600W |
HS |
|
7081071 |
Assembly, riser, single stack, 1U |
DBO |
See "Servicing PCIe Risers (CRU)" at
|
7085209 |
HBA, 12 Gb SAS PCIe 8-port RAID internal with flash module |
DBO |
See "Servicing the Internal HBA Card (FRU)" at |
7086345 |
Assembly, super cap, 13.5 volt, 6.4F, SAS3 HBA |
DBO |
See "Servicing the Internal HBA Card (FRU)" at |
7086346 |
Cable, super cap, 620M, 6-pin, straight, SAS3 HBA |
DBO |
See "Servicing the Internal HBA SAS Cable assembly" at
|
7089073 |
Fan module |
HS |
See "Servicing Fan Modules (CRU)" at
|
7095106 |
CPU, E5-2699 v4, 2.2 GHz, 145W, 22 core, C-1 (SR1XD) |
DBO |
See "Servicing Processors (FRU)" at
|
7097205 |
Assembly, 8DBP, 1U/2U |
DBO |
See "Servicing the Disk Backplane (FRU)" at
|
7098505 |
Assembly, motherboard, 1U |
DBO |
|
Table D-6 lists the replaceable parts for Oracle Server X5-2 compute servers. Unless otherwise noted, the repair procedures are in Oracle Server X5-2 Service Manual.
Note:
All replacement parts listed in the following table are FRUs when covered under the Premier Support of Systems warranty.
Table D-6 Replacement Parts for Oracle Server X5-2 Compute Servers
Part Number | Description | Repair Category | Repair Procedure |
---|---|---|---|
350-1719 |
Assembly, slim rail, 1U - 2U, snap in |
DBO |
|
370-5621 |
3 volt lithium battery |
DBO |
See "Servicing the Battery" at
|
542-0287 |
Drive, 600 GB 10K, SAS2, SFF |
DBO |
See "Servicing Storage Drives (CRU)" at
|
7014226 |
Cable, interlock, 125 mm |
DBO |
See "Servicing the Power, FIM, Disk Backplane Data, and DVD Cables" at |
7046442 |
Assembly, dual port, QDR CX3, host channel adapter |
DBO |
|
7051223 |
Assembly, Dual 10 GbE SFP+LP, X8 PCIe 2.0, RoHS:Y |
DBO |
See Sun Dual 10GbE SFP+ PCIe 2.0 Low Profile Adapter User's Guide at
See "Servicing PCIe Cards (CRU)" at
|
7067728 |
Heat sink, CPU 1U |
DBO |
See "Servicing Processors (FRU)" at
|
7077680 |
Assembly, riser, 2S, 1U |
DBO |
See "Servicing PCIe Risers (CRU)" at
|
7078072 |
DIMM, 32 GB, LRDIMM, DDR4, 2133 |
DBO |
See "Servicing the DIMMs (CRU)" at
|
7079395 |
Power supply, AC, A256, F, 12V, 600W |
HS |
|
7081071 |
Assembly, riser, single stack, 1U |
DBO |
See "Servicing PCIe Risers (CRU)" at
|
7085209 |
HBA, 12 Gb SAS PCIe 8-port RAID internal with flash module |
DBO |
See "Servicing the Internal HBA Card (FRU)" at |
7086345 |
Assembly, super cap, 13.5 volt, 6.4F, SAS3 HBA |
DBO |
See "Servicing the Internal HBA Card (FRU)" at |
7086346 |
Cable, super cap, 620M, 6-pin, straight, SAS3 HBA |
DBO |
See "Servicing the Internal HBA SAS Cable assembly" at
|
7089073 |
Fan module |
HS |
See "Servicing Fan Modules (CRU)" at
|
7095106 |
CPU, E5-2699 v3, 2.3 GHz, 145W, 18 core, C-1 (SR1XD) |
DBO |
See "Servicing Processors (FRU)" at
|
7097205 |
Assembly, 8DBP, 1U/2U |
DBO |
See "Servicing the Disk Backplane (FRU)" at
|
7098505 |
Assembly, motherboard, 1U |
DBO |
|
Sun Server X4-2 Parts
Figure D-5 shows the front view of the Sun Server X4-2.
Figure D-6 shows the rear view of the Sun Server X4-2.
Table D-7 lists the replaceable parts for Sun Server X4-2 compute servers. Unless otherwise noted, the repair procedures are in Sun Server X4-2 Service Manual.
Note:
All replacement parts listed in the following table are FRUs when covered under the Premier Support of Systems warranty.
Table D-7 Replacement Parts for Sun Server X4-2 Compute Servers
Part Number | Description | Repair Category | Repair Procedure |
---|---|---|---|
7013526 |
Fan module |
HS |
See "Servicing Fan Modules" in Sun Server X4-2 Service Manual at
|
7018701 |
DIMM, 16 GB, DDR3, 2RX4, 1600, 1.35 V |
DBO |
See "Servicing the DIMMs" at
|
7020774 |
Heat sink, CPU 1U, 60 mm FIN |
DBO |
See "Servicing Storage Drives (CRU)" at
|
7023303 |
Dual 16 Gigabit/Sec Fiber Channel / 10 GbS FCoE Host Adapter, QLogic |
See "Install a PCIe Card in PCIe Slot 1 or 2" at
|
|
7027478 |
Disk Backplane, RoHS:Y |
DBO |
See "Servicing the Disk Backplane (FRU)" at
|
7039841 |
Front indicator module |
DBO |
See "Servicing PCIe Risers" at
|
7046442 |
Assembly, dual port, QDR CX3, host channel adapter |
DBO |
|
7047503 |
Assembly, 6 GB, SAS RAID disk PCIe HBA, RoHS:Y |
DBO |
See "Servicing Storage Drives" at
|
7048707 |
Assembly, riser, double stack |
DBO |
See "Servicing PCIe Risers" at
|
7048710 |
1-slot PCI Express riser assembly |
DBO |
See "Servicing PCIe Risers" at
|
7051223 |
Assembly, Dual 10 GbE SFP+LP, X8 PCIe 2.0, RoHS:Y |
DBO |
See Sun Dual 10GbE SFP+ PCIe 2.0 Low Profile Adapter User's Guide at |
7057184 |
Assembly, battery carrier remote |
HS |
|
7058153 |
Assembly, motherboard, X4-2 |
DBO |
|
7060020 |
Universal upgrade remote battery kit |
EBO |
|
7060951 |
Power supply, AC, A256, F, 12V, 600W |
HS |
|
7069232 |
CPU, E5-2697 v2, 12-core, 2.7 GHz |
DBO |
See "Servicing Processors" at
|
See Also:
Sun Server X4-2 Service Animations at
Parts for Storage Servers
The following topics identify the replacement parts for the Recovery Appliance storage servers:
Oracle Exadata Storage Server X7-2 High Capacity Server Parts
The following figure shows the front view of the Oracle Exadata Storage Server X7-2 High Capacity Server.
Figure D-7 Front View of Oracle Exadata Storage Server X7-2 High Capacity Server
Description of "Figure D-7 Front View of Oracle Exadata Storage Server X7-2 High Capacity Server "
The following figure shows the rear view of the Oracle Exadata Storage Server X7-2 High Capacity Server.
Figure D-8 Rear View of Oracle Exadata Storage Server X7-2 High Capacity Server
Description of "Figure D-8 Rear View of Oracle Exadata Storage Server X7-2 High Capacity Server"
The following table lists the replaceable parts for Oracle Exadata Storage Server X7-2 High Capacity Servers. Refer to this table only if you have a basic warranty. All replacement parts shown in the following table are considered FRU when covered under Premier Support of Systems warranty.
Table D-8 Replacement Parts for Oracle Exadata Storage Server X7-2 High Capacity Servers
Part Number | Description | Repair Category | Coverage under Basic Warranty | Repair Procedure |
---|---|---|---|---|
350-1719 |
Assembly, 1U-2U Snap-in, slim rail rack |
EBO |
CRU |
|
370-5621 |
3 volt lithium battery |
EBO |
FRU |
See "Servicing the Battery" in Oracle Exadata Storage Server X7-2 EF and HC Service Manual at |
7322171 |
Indicator assembly, LFIM |
EBO |
FRU |
See "Servicing the Front LED Indicator Module" in Oracle Exadata Storage Server X7-2 EF and HC Service Manual at |
7341141 |
12-slot disk backplane assembly |
EBO |
FRU |
See "Servicing the Disk Backplane" in Oracle Exadata Storage Server X7-2 EF and HC Service Manual at |
7333459 |
Power Supply, A266, 1200W, AC Input |
HS |
FRU |
|
7322166 |
Fan assembly, 2U |
HS |
FRU |
See "Servicing Fan Modules" in Oracle Exadata Storage Server X7-2 EF and HC Service Manual at |
7046442 |
Assembly, dual 40Gb/Sec (4x) QDR InfiniBand Host Channel Adapter Module M3 |
EBO |
FRU |
|
7322160 |
Heat sink, CPU |
EBO |
FRU |
See "Servicing Processors (FRU)" in Oracle Exadata Storage Server X7-2 EF and HC Service Manual at |
7332759 |
Assembly, drive, 10 TB, 3.5 inch, SAS/7200rpm |
HS |
FRU |
See "Servicing Storage Drives" in Oracle Exadata Storage Server X7-2 EF and HC Service Manual at |
7330697 |
DIMM, 16 GB, RDIMM, DDR4, 2666 |
EBO |
FRU |
See "Servicing the DIMMS" in Oracle Exadata Storage Server X7-2 EF and HC Service Manual at |
7332895 |
HBA, 12 Gbps SAS PCIe 16-port internal RAID with flash module |
EBO |
FRU |
See "Servicing an Internal HBA Card and HBA Super Capacitor" in Oracle Exadata Storage Server X7-2 EF and HC Service Manual at |
7086345 |
HBA Assembly, super cap, 13.5V, 6.4F, SAS3 HBA |
EBO |
FRU |
See "Servicing an Internal HBA Card and HBA Super Capacitor" in Oracle Exadata Storage Server X7-2 EF and HC Service Manual at |
7315464 |
SAS-3 Data Cable Assembly |
EBO |
FRU |
See "Servicing SAS Cables" in Oracle Exadata Storage Server X7-2 EF and HC Service Manual at |
7341587 |
M.2,150GB,SATA,22x80mm,SSD,INTEL, DC S3520 |
EBO |
FRU |
See "Servicing the Internal M.2 Flash SSDs" in Oracle Exadata Storage Server X7-2 EF and HC Service Manual at |
7335943 |
6.4TB Flash Accelerator F640 NVMe Card |
EBO |
FRU |
See "Servicing PCIe Cards" in Oracle Exadata Storage Server X7-2 EF and HC Service Manual at |
7347511 |
CPU, XEON S-4114 , 2.2G, 85W, 10 CORE, (SR3GK) |
EBO |
FRU |
See "Servicing Processors (FRU)" in Oracle Exadata Storage Server X7-2 EF and HC Service Manual at |
7335280 |
System board assembly |
EBO |
FRU |
See "Servicing the Motherboard Assembly" in Oracle Exadata Storage Server X7-2 EF and HC Service Manual at |
Oracle Server X6-2L and X5-2L Parts
Figure D-9 shows the front view of the Oracle Server X6-2L or X5-2L. The hard drives are numbered from left to right, starting in the lower left. The drives in the bottom row are numbers 0, 1, 2, and 3. The drives in the middle row are numbers 4, 5, 6, and 7. The drives in the top row are numbers 8, 9, 10, and 11.
Figure D-9 Front View of Oracle Server X6-2L or X5-2L
Description of "Figure D-9 Front View of Oracle Server X6-2L or X5-2L"
Figure D-10 shows the rear view of an Oracle Server X6-2L or X5-2L storage server.
Figure D-10 Rear View of Oracle Server X6-2L or X5-2L
Description of "Figure D-10 Rear View of Oracle Server X6-2L or X5-2L"
Table D-9 lists the replaceable parts for the Oracle Server X6-2L. Unless otherwise noted, the repair procedures are in Oracle Server X6-2L Service Manual.
Note:
All replacement parts listed in the following table are FRUs when covered under Premier Support of Systems warranty.
Table D-9 Replacement Parts for Oracle Server X6-2L Storage Servers
Part Number | Description | Repair Category | Repair Procedure |
---|---|---|---|
350-1719 |
Assembly, 1U-2U Snap-in, slim rail rack |
EBO |
|
370-5621 |
3 volt lithium battery |
EBO |
See "Servicing the Battery (CRU)" at
|
7014226 |
Cable, interlock, 125 mm |
EBO |
See "Servicing SAS Cables (FRU)" at
|
7017231 |
Indicator assembly, right |
EBO |
See "Servicing the Front LED/USB Indicator Modules (FRU)" at
|
7023515 |
Disk backplane assembly, 2 rear |
EBO |
See "Servicing the Front and Rear Storage Drive Backplanes (FRU)" at
|
7044130 |
Power Supply, A258, 1000W, AC Input |
HS |
|
7045042 |
Fan assembly, 2U, 80 x 80, Ferrite, center rotate |
HS |
See "Servicing Fan Modules (CRU)" at
|
7046442 |
Assembly, dual port, QDR CX3, host channel adapter |
EBO |
|
7064884 |
Heat sink, CPU |
EBO |
See "Servicing Processors (FRU)" at
|
7066824 |
Assembly, drive, 8 TB, 3.5 inch, SAS/7200rpm |
HS |
See "Servicing Storage Drives and Rear Drives (CRU)" at
|
7069337 |
Assembly, backplane, 12X3.5, W/SAS expansion, 2U |
EBO |
See "Servicing the Front and Rear Storage Drive Backplanes (FRU)" at
|
7078070 |
DIMM, 16 GB, RDIMM, DDR4, 2400 |
EBO |
See "Servicing the DIMMS (CRU)" at
|
7085209 |
HBA, 12 Gb SAS PCIe 8-port RAID internal with flash module |
EBO |
See "Servicing the Oracle Storage 12 Gb/s SAS PCIe RAID HBA Card (FRU)" at |
7086345 |
Assembly, super cap, 13.5 volt, 6.4F, SAS3 HBA |
EBO |
See "Servicing the Oracle Storage 12 Gb/s SAS PCIe RAID HBA Card (FRU)" at |
7086346 |
Cable, super cap, 620M, 6-pin, straight, SAS3 HBA |
EBO |
See "Servicing SAS Cables (FRU)" at
|
7090170 |
Flash drive, MLC, OSA ID, USB, 8 GB |
EBO |
See "Servicing the Internal USB Flash Drives (CRU)" at
|
7090698 |
Assembly, 3.2 TB eMLC flash F320 NVMe card |
EBO |
See Oracle Flash Accelerator F320 PCIe Card User Guide at |
7095102 |
CPU, E5-2630 V4, 2.2 G, 85 W, 10 CORE, R-2 (SR206) |
EBO |
See "Servicing Processors (FRU)" at
|
7096185 |
Assembly, indicator, left |
EBO |
See "Servicing the Front LED/USB Indicator Modules (FRU)" at
|
7098504 |
ASM, MOBO tray |
EBO |
Table D-10 lists the replaceable parts for the Oracle Server X5-2L. Unless otherwise noted, the repair procedures are in Oracle Server X5-2L Service Manual.
Note:
All replacement parts listed in the following table are FRUs when covered under Premier Support of Systems warranty.
Table D-10 Replacement Parts for Oracle Server X5-2L Storage Servers
Part Number | Description | Repair Category | Repair Procedure |
---|---|---|---|
350-1719 |
Assembly, 1U-2U Snap-in, slim rail rack |
EBO |
|
370-5621 |
3 volt lithium battery |
EBO |
See "Servicing the Battery (CRU)" at
|
7014226 |
Cable, interlock, 125 mm |
EBO |
See "Servicing SAS Cables (FRU)" at
|
7017231 |
Indicator assembly, right |
EBO |
See "Servicing the Front LED/USB Indicator Modules (FRU)" at
|
7023515 |
Disk backplane assembly, 2 rear |
EBO |
See "Servicing the Front and Rear Storage Drive Backplanes (FRU)" at
|
7044130 |
Power Supply, A258, 1000W, AC Input |
HS |
|
7045042 |
Fan assembly, 2U, 80 x 80, Ferrite, center rotate |
HS |
See "Servicing Fan Modules (CRU)" at
|
7046442 |
Assembly, dual port, QDR CX3, host channel adapter |
EBO |
|
7064884 |
Heat sink, CPU |
EBO |
See "Servicing Processors (FRU)" at
|
7066824 |
Assembly, drive, 4 TB, 3.5 inch, SAS/7200rpm |
HS |
See "Servicing Storage Drives and Rear Drives (CRU)" at
|
7069337 |
Assembly, backplane, 12X3.5, W/SAS expansion, 2U |
EBO |
See "Servicing the Front and Rear Storage Drive Backplanes (FRU)" at
|
7078070 |
DIMM, 8 GB, RDIMM, DDR4, 2133 |
EBO |
See "Servicing the DIMMS (CRU)" at
|
7085209 |
HBA, 12 Gb SAS PCIe 8-port RAID internal with flash module |
EBO |
See "Servicing the Oracle Storage 12 Gb/s SAS PCIe RAID HBA Card (FRU)" at |
7086345 |
Assembly, super cap, 13.5 volt, 6.4F, SAS3 HBA |
EBO |
See "Servicing the Oracle Storage 12 Gb/s SAS PCIe RAID HBA Card (FRU)" at |
7086346 |
Cable, super cap, 620M, 6-pin, straight, SAS3 HBA |
EBO |
See "Servicing SAS Cables (FRU)" at
|
7090170 |
Flash drive, MLC, OSA ID, USB, 8 GB |
EBO |
See "Servicing the Internal USB Flash Drives (CRU)" at
|
7090698 |
Assembly, 1.6 TB eMLC flash F160 NVMe card, Aura 3.0 with LP BRKT |
EBO |
See Oracle Flash Accelerator F160 PCIe Card User Guide at |
7095102 |
CPU, E5-2630 V3, 2.4G, 85W, 8 CORE, R-2 (SR206) |
EBO |
See "Servicing Processors (FRU)" at
|
7096185 |
Assembly, indicator, left |
EBO |
See "Servicing the Front LED/USB Indicator Modules (FRU)" at
|
7098504 |
ASM, MOBO tray |
EBO |
Sun Server X4-2L Parts
Figure D-11 shows the front view of the Sun Server X4-2L. The hard drives are numbered from left to right, starting in the lower left. The drives in the bottom row are numbers 0, 1, 2, and 3. The drives in the middle row are numbers 4, 5, 6, and 7. The drives in the top row are numbers 8, 9, 10, and 11.
Figure D-11 Front View of Sun Server X4-2L
Description of "Figure D-11 Front View of Sun Server X4-2L"
Figure D-12 shows the rear view of a Sun Server X4-2L storage server.
Table D-11 lists the replaceable parts for the Sun Server X4-2L. Unless otherwise noted, the repair procedures are in Sun Server X4-2L Service Manual.
Note:
All replacement parts listed in the following table are FRUs when covered under Premier Support of Systems warranty.
Table D-11 Replacement Parts for Sun Server X4-2L Storage Servers
Part Number | Description | Repair Category | Repair Procedure |
---|---|---|---|
371-5002 |
USB drive, 4 GB |
EBO |
See "Servicing the Internal USB Flash Drives" in Sun Server X4-2L Service Manual at
|
7014226 |
Cable, interlock, 125 mm |
EBO |
See "Servicing Cables" at
|
7014391 |
Expander assembly, 2U |
EBO |
See "Servicing the SAS Expander Module" at
|
7017231 |
Indicator assembly, right |
EBO |
See "Servicing the Front LED/USB Indicator Modules" at
|
7018701 |
DIMM, 16 GB, DDR3, 1600, 2Rx4, 1.35V |
EBO |
See "Servicing the DIMMS" at
|
7020486 |
DIMM, 8 GB, DDR3, 1600, 2Rx4, 1.35V |
EBO |
See "Servicing the DIMMs" at
|
7020776 |
Heatsink, CPU, 2U, 60 MM FIN, RoHS:YU |
EBO |
See "Servicing Storage Drives and Rear Drives" at
|
7023515 |
Disk backplane assembly, 2 rear |
EBO |
See "Servicing the Front and Rear Storage Drive Backplanes" at
|
7027479 |
Disk backplane assembly, 4-Slot 3.5" RoHS:Y |
EBO |
See "Servicing the Front and Rear Storage Drive Backplanes" at
|
7044130 |
Power Supply, A258, 1000 Watt AC Input |
HS |
|
7045042 |
Fan assembly, 2U, 80 x 80, Ferrite, center_rotate |
HS |
See "Servicing Fan Modules" at
|
7046442 |
Assembly, dual port, QDR CX3, host channel adapter |
EBO |
|
7047503 |
Assembly, 6 GB, SAS RAID disk PCIe HBA, RoHS:Y |
DBO |
See "Servicing Storage Drives and Rear Drives" at
|
7048864 |
Indicator assembly, left, 2U |
EBO |
See "Servicing the Front LED/USB Indicator Modules (FRU)" at
|
7057184 |
Assembly, battery carrier remote |
HS |
|
7058152 |
Assembly, motherboard, X4-2L |
EBO |
See "Servicing the Motherboard Assembly" at
|
7060020 |
Universal upgrade remote battery kit |
EBO |
|
7069200 |
Assembly, 800 GB eMLC flash PCIe card |
EBO |
See "Servicing PCIe Cards" at
|
7069242 |
CPU, E5-2630 v2, 6-core, 2.6 Ghz |
EBO |
See "Servicing Processors" at
|
7070656 |
Disk assembly, 1.2 TB, SAS2 |
HS |
See "Servicing Storage Drives and Rear Drives" at
|
7106353 |
4 TB 7200 rpm SAS HDD with bracket |
DBO |
See "Servicing Storage Drives and Rear Drives" at
|
Parts for InfiniBand Switches
Table D-12 lists the replaceable parts for the InfiniBand switches used in Recovery Appliance. See "Cables and Cable Accessories for Recovery Appliance" for information about InfiniBand cables.
Note:
All replacement parts listed in the following table are FRUs when covered under Premier Support of Systems warranty.
Table D-12 Replacement Parts for InfiniBand Switches
Part Number | Description | Repair Category | Repair |
---|---|---|---|
300-2143 |
760 watt power supply, RoHS:Y |
HS |
See Sun Datacenter InfiniBand Switch 36 User's Guide at
|
300-2299 |
760 watt AC input power supply |
HS |
See Sun Datacenter InfiniBand Switch 36 User's Guide at
|
350-1312 |
Fan module for Sun Datacenter InfiniBand Switch 36, RoHS:Y |
HS |
See Sun Datacenter InfiniBand Switch 36 User's Guide at
|
350-1566 |
Fan module, 1 RU, Sanace, reverse |
HS |
See Sun Datacenter InfiniBand Switch 36 User's Guide at
|
371-2210 |
CR2032 3 v battery, RoHS:Y |
IR |
See Sun Datacenter InfiniBand Switch 36 User's Guide at
|
541-3495 |
Sun Datacenter InfiniBand Switch 36, RoHS:YL |
IR |
See Sun Datacenter InfiniBand Switch 36 User's Guide at
|
7052970 |
Sun Datacenter InfiniBand Switch 36, RoHS:YL |
IR |
See Sun Datacenter InfiniBand Switch 36 User's Guide at
|
7061031 |
Fan module, 1 RU, Sanace, reverse |
HS |
See Sun Datacenter InfiniBand Switch 36 User's Guide at
|
Parts for Cisco Switch
Table D-13 lists replaceable parts for the Cisco switch used with Recovery Appliance.
Note:
All replacement parts listed in the following table are FRUs when covered under Premier Support of Systems warranty.
Table D-13 Replacement Parts for Cisco Switch
Part Number | Description | Repair Category | Repair |
---|---|---|---|
7023685 |
Cisco Catalyst 4948 switch, RoHS:Y |
IR |
See chapter 3 in Catalyst 4948E and Catalyst 4948E-F Switch Installation Guide at |
7024423 |
Power supply for Cisco Catalyst 4948 switch, RoHS:Y |
HS |
See chapter 4 in Catalyst 4948E and Catalyst 4948E-F Switch Installation Guide at |
7024424 |
Cooling fan for Cisco Catalyst 4948 switch, RoHS:Y |
HS |
See chapter 4 in Catalyst 4948E and Catalyst 4948E-F Switch Installation Guide at |
Parts for Power Distribution Units
Table D-14 lists the replacement parts for the power distribution units (PDUs). Given the number of cables and connections, Oracle recommends that you shut down the Recovery Appliance rack when replacing power distribution unit parts.
Note:
All replacement parts listed in the following table are FRUs when covered under Premier Support of Systems warranty.
Table D-14 Replacement Parts for Power Distribution Units
Part Number | Description | Repair Category | Repair |
---|---|---|---|
180-2379 |
13A/250V 90 degree IEC 320 Sheet E to IEC 320 C13 cord, 1 meter, RoHS:Y |
HS |
Not applicable |
180-2380 |
13A/250V 90 degree IEC 320 Sheet E to IEC 320 C13 cord, 2 meter, RoHS:Y |
HS |
Not applicable |
371-4000 |
Three-phase PDU: 15kV,5-Pin, IEC309 32A, 5 PIN 230/400V, 3ph IP44, International, RoHS:Y |
IR |
See "Replacing a Power Distribution Unit" of this guide. |
371-4199 |
Single-phase PDU: 15kVA, with three 30A/250V 2-Pole/3-Wire NEMA L6-30P Plugs, North America, RoHS:Y |
IR |
See "Replacing a Power Distribution Unit" of this guide. |
371-4201 |
Single-phase PDU: 15kVA, with three Blue 32A/240V Splash-proof 2-Pole/3-Wire IEC 60309 Plugs, International, RoHS:Y |
IR |
See "Replacing a Power Distribution Unit" of this guide. |
371-5039 |
Single-phase PDU: 22k VA Hubbell CS8265C PlugNo X-Option |
IR |
See "Replacing a Power Distribution Unit" of this guide. |
371-5040 |
Single-phase PDU: 22k VA Blue 32A IEC 60309 Plug No X-Option |
IR |
See "Replacing a Power Distribution Unit" of this guide. |
7051908 |
Three-phase PDU: 15kVA, IEC309 60A, 4 PIN, 250VAC, 3ph IP67, North America, RoHS:Y |
IR |
See "Replacing a Power Distribution Unit" of this guide. |
Cables and Cable Accessories for Recovery Appliance
Table D-15 lists the replacement cables and cable accessories for Recovery Appliance.
Note:
All replacement parts listed in the following table are FRUs when covered under Premier Support of Systems warranty.
Table D-15 Replacement Cables for Recovery Appliance
Part Number | Description | Repair Category | Repair |
---|---|---|---|
350-1287 |
Slim rail, CMA, 1U-2U for a storage server |
EBO |
|
350-1546 |
Cable management arm (CMA) 1U, RoHS:Y for compute server |
DBO |
|
350-1519 |
Serial cable kit, RoHS:Y with the following:
|
HS |
See Sun Datacenter InfiniBand Switch 36 User's Guide at
|
350-1637 |
Label assembly, EV2, 2-way, upgrade, label |
HS |
|
350-1638 |
Label assembly EV2, 3-way, service upgrade, label |
HS |
|
350-1639 |
Label assembly EV2, 4-way, service upgrade, label |
HS |
|
350-1640 |
Label assembly EV2, 5-way, service upgrade, label |
HS |
|
350-1641 |
Label assembly EV2, 6-way, service upgrade, label |
HS |
|
350-1642 |
Label assembly EV2, 7-way, service upgrade, label |
HS |
|
350-1643 |
Label assembly EV2, 8-way, service upgrade, label |
HS |
|
530-4445 |
QSFP InfiniBand passive copper cable, 10 GbE, 3 m, RoHS:Y |
HS |
See Sun Datacenter InfiniBand Switch 36 User's Guide at
Note: There is a loss of redundancy when replacing cables. |
530-4446 |
QSFP InfiniBand passive copper cable, 10 GbE, 5 m, RoHS:Y |
HS |
See Sun Datacenter InfiniBand Switch 36 User's Guide at
Note: There is a loss of redundancy when replacing cables. |
530-4403 |
4x QSFP copper QDR InfiniBand cable, 2 m, RoHS:Y |
HS |
See Sun Datacenter InfiniBand Switch 36 User's Guide at
Note: There is a loss of redundancy when replacing cables. |
530-4404 |
4x QSFP copper QDR InfiniBand cable, 3 m, RoHS:Y |
HS |
See Sun Datacenter InfiniBand Switch 36 User's Guide at
|
530-4415 |
4x QSFP copper QDR InfiniBand cable, 5 m, RoHS:Y |
HS |
See Sun Datacenter InfiniBand Switch 36 User's Guide at
|
530-4432 |
Ethernet cable, Cat 5/5E, RJ45 to RJ45, 7 foot, blue, RoHS:Y |
HS |
See Catalyst 4948E and Catalyst 4948E-F Switch Installation Guide at |
530-4433 |
Ethernet cable, Cat 5/5E, RJ45 to RJ45, 10 foot, red, RoHS:Y |
HS |
See Catalyst 4948E and Catalyst 4948E-F Switch Installation Guide at |
530-4434 |
Ethernet cable, Cat 5/5E, RJ45 to RJ45, 7 foot, red, RoHS:Y |
HS |
See Catalyst 4948E and Catalyst 4948E-F Switch Installation Guide at |
530-4435 |
Ethernet cable, Cat 5/5E, RJ45 to RJ45, 10 foot, black, RoHS:Y |
HS |
See Catalyst 4948E and Catalyst 4948E-F Switch Installation Guide at |
530-4436 |
Ethernet cable, Cat 5/5E, RJ45 to RJ45, 7 foot, black, RoHS:Y |
HS |
See Catalyst 4948E and Catalyst 4948E-F Switch Installation Guide at |
530-4437 |
Ethernet cable, Cat 5/5E, RJ45 to RJ45, 7 foot, orange, RoHS:Y |
HS |
See Catalyst 4948E and Catalyst 4948E-F Switch Installation Guide at |
530-4438 |
Ethernet cable, Cat 5/5E, RJ45 to RJ45, 10 foot, black, RoHS:Y |
HS |
See Catalyst 4948E and Catalyst 4948E-F Switch Installation Guide at |
530-4444 |
QSFP to QSFP Passive Copper Cable, 1 m, RoHS:Y |
HS |
See Sun Datacenter InfiniBand Switch 36 User's Guide at
|
530-4445 |
QSFP passive copper cable, 10 GE, 3 m |
HS |
See Sun Datacenter InfiniBand Switch 36 User's Guide at
|
530-4502-01 |
Ethernet cable, Cat 5/5E, 10 foot, blue, RoHS:Y |
HS |
See Catalyst 4948E and Catalyst 4948E-F Switch Installation Guide at |
7015400 |
Power cable, jumper, SR2, 2m C14RA, 10A, C13 |
HS |
See "Replacing a Power Distribution Unit" of this guide. |
7042273 |
Slim rail, cable management arm, 1U-2U for a storage server |
EBO |
|
7102869 |
Passive fiber InfiniBand cable, 10 m, RoHS:Y |
HS |
Note: Purchase two QSFP SR Transceivers (Part Number X2124A-N) for each passive fiber cable. |
7102870 |
Passive fiber InfiniBand cable, 20 m, RoHS:Y |
HS |
See Sun Datacenter InfiniBand Switch 36 User's Guide at
Note: Purchase two QSFP SR Transceivers (Part Number X2124A-N) for each passive fiber cable. |
7102871 |
Passive fiber InfiniBand cable, 50 m, RoHS:Y |
HS |
See Sun Datacenter InfiniBand Switch 36 User's Guide at
Note: Purchase two QSFP SR Transceivers (Part Number X2124A-N) for each passive fiber cable. |