4.32 chg-acg-mic

Use this command to change the values of ACG controls assigned to certain queries. The control can apply to all queries or to specific query services and called party digits. A particular control is selected to be changed by either specifying that it is the type=all control or specifying its service and digits.

Parameters

aintvl (optional)
AIN interval index
Range:
1 - 15
Default:
No change to the current value
dgts (optional)
Digits
Range:
000 - 999, 000000 - 9999999999

Specify 3 digits or 6-10 digits.

drtn (optional)
Duration index. The amount of time that the ACG is in effect. This number is mapped to a time value at the LNP node.
Range:
1 - 13
Default:
No change to the current value
intvl (optional)
Interval index. The amount of time between ACGs. This number is mapped to a time value for the LNP node.
Range:
0 - 15
Default:
No change to the current value
nd (optional)
New number of digits
Range:
3, 6 - 10
Default:
No change to the current value
serv (optional)
Query service
Range:
ain
in
type (optional)
Type of control
Range:
all
sd
Default:
sd

Example

To change the type=all MIC to use 3 digits:

chg-acg-mic:type=all:nd=3

To change the MIC for AIN queries for 919-460-2132 to use an interval index of 15:

chg-acg-mic:serv=ain:dgts=9194602132:aintvl=15

To change the MIC for IN queries for 919-xxx-xxxx to use a duration index of 9 and an interval index of 5:

chg-acg-mic:serv=in:dgts=919:drtn=9:intvl=5

Dependencies

If the type=all parameter is specified, then the nd, drtn, intvl, or aintvl parameter must be specified.

If the type=all parameter is specified, then the serv and dgts parameters cannot be specified.

If the type=sd parameter is specified, then the serv and dgts parameters must be specified.

If the type=sd parameter is specified, then the nd parameter cannot be specified.

If the serv=ain parameter is specified, then the drtn or aintvl parameter must be specified.

If the serv=ain parameter is specified, then the intvl parameter cannot be specified.

If the serv=in parameter is specified, then the drtn or intvl parameter must be specified.

If the serv=in parameter is specified, then the aintvl parameter cannot be specified.

The dgts parameter value must be either 3 digits in the range 000-999 or 6-10 digits in the range 000000-9999999999.

The nd parameter value must be 3 or 6-10 to indicate the number of new digits.

The LNP feature must be turned on before this command can be entered.

If the type=all parameter is specified, then a MIC with type=all must exist.

If the type=sd parameter is specified, then a MIC with the same service and digits must exist.

Notes

None

Output

chg-acg-mic:type=all:nd=31

    rlghncxa03w 04-01-28 08:50:12 EST  EAGLE 31.3.0
    ACG MIC table is (11 of 256) 4% full of type SD
    CHG-ACG-MIC: MASP A - COMPLTD 
;