4.279 ent-acg-mic

Use this command to assign Automatic Call Gapping (ACG) controls to certain queries. The control can apply to all queries or to specific query services and called party digits. If the EAGLE LNP query service receives a query to which a control applies, then the EAGLE sends an ACG component, encoded as configured, with the response.

Parameters

drtn (mandatory)
Duration index. The amount of time that the ACG is in effect. This number is mapped to a time value at the LNP node.
Range:
1 - 13
Default:
The current value
aintvl (optional)
AIN interval index
Range:
1 - 15
Default:
The current value
dgts (optional)
Digits
Range:
000 - 999, 000000 - 9999999999

Specify 3 digits or 6-10 digits.

intvl (optional)
IN Interval index. The amount of time between ACGs. This number is mapped to a time value for the LNP node.
Range:
0 - 15
Default:
Current value
nd (optional)
Number of digits
Range:
3, 6 - 10
Default:
The current value
serv (optional)
Query service
Range:
ain
in
type (optional)
Type of control
Range:
all
sd
Default:
sd

Example

ent-acg-mic:type=all:nd=6:drtn=6:intvl=2:aintvl=7

ent-acg-mic:serv=ain:dgts=9194602132:drtn=13:aintvl=1

ent-acg-mic:type=sd:serv=in:dgts=919:drtn=8:intvl=3

Dependencies

If the type=all parameter is specified, then the nd, intvl, and aintvl parameters must be specified.

If the type=all parameter is specified, the optional parameters serv and dgts cannot be specified.

If the type=sd parameter is specified, the optional parameters serv and dgts must be specified.

If the type=sd parameter is specified, then the nd parameter cannot be specified.

If the serv=in parameter is specified, the aintvl parameter cannot be specified.

If the serv=ain parameter is specified, the optional parameter intvl cannot be specified.

If the serv=in parameter is specified, the optional parameter intvl must be specified.

If the serv=ain parameter is specified, the optional parameter aintvl must be specified.

The dgts parameter value must be specified as 3 or 6–10 digits.

A valid value must be specified for the nd parameter.

The LNP feature must be turned on before this command can be entered.

If the type=all parameter is specified, then an MIC with the type=all parameter cannot already exist.

If the type=sd parameter is specified, a MIC with the same service and digits must not already exist.

The ACG MIC table must be accessible.

A maximum of 256 type=sd MICs are allowed.

Notes

None

Output

ent-acg-mic:type=all:nd=6:drtn=6:intvl=2:aintvl=7

    rlghncxa03w 04-02-28 08:50:12 EST  EAGLE 31.3.0
    ACG MIC table is (11 of 256) 4% full of type SD
    ENT-ACG-MIC: MASP A - COMPLTD 
;