4.35 chg-aiqopts

Use this command to provision AIQ specific data. This command updates the AIQOPTS table. 

Parameters

digmaxlen (optional)
Maximum Length of Digit String. The maximum length of a digit string that is considered valid in the Digits (Dialed) field of an AnalyzedInformation query.
Range:
1 - 32
Default:
No change to the current value
System Default:
32
digminlen (optional)
Minimum Length of Digit String. The minimum length of a digit string that is considered valid in the Digits (Dialed) field of an AnalyzedInformation query.
Range:
1 - 32
Default:
No change to the current value
System Default:
1
pfx (optional)
Digit String. The digit string associated with a Trigger Type (value of trigtype parameter). The value specified for the pfx parameter is encoded in the response message.
Range:
1-21 digits, none

none —deletes the associated Trigger Type value

Default:
No change to the current value
System Default:
none
resfmt (optional)
Response format. The format of outgoing routing digits in the AnalyzedInformation response message.
Range:
pfxdn
the value specified for the pfx  parameter + the incoming dialed digits
pfx
the value specified for the pfx parameter
Default:
No change to the current value
System Default:
pfxdn
respar (optional)

Response Digits. The TCAP field used to encode the AnalyzedInformation response message.

Range:
rtdigits
TCAPRoutingDigitsfield
digits
TCAPDigits(Dialed)field
Default:
No change to the current value
System Default:
rtdigits
tcaperr (optional)

TCAP Error Code. The TCAP error code used in a Return Error response.

Range:
129 - 255
  • 129—UnrecognizedMIN
  • 130—UnrecognizedESN
  • 131—MIN/HLR Mismatch
  • 132—OperationSequenceProblem
  • 133—ResourceShortage
  • 134—OperationNotSupported
  • 135—TrunkUnavailable
  • 136—ParameterError
  • 137—SystemFailure
  • 138—UnrecognizedParameterValue
  • 139—FeatureInactive
  • 140—MissingParameter
  • 141-239—Reserved
  • 240-255—Reserved for Protocol Extension
Default:
No change to the current value
System Default:
138
trigtype (optional)

TriggerType Value. An individual trigger used to specify an association between a trigger and a corresponding address digit string (value of pfx parameter).

A maximum of 20 trigtype - pfx entries are supported. The pfx digit string corresponding to the specified Trigger Type present in the Incoming AnalyzedInfo Query is encoded in the Response message.

Range:
0 - 255

Table 4-1  lists the mnemonic for each TRIGTYPE decimal value.

Example

This example specifies the provisioning of a Trigger Type – Prefix string pair:

chg-aiqopts:trigtype=2:pfx=65432

This example deletes an already provisioned Trigger Type:

chg-aiqopts:trigtype=2:pfx=none

This example specifies the digminlen-digmaxlen range (5-7):

chg-aiqopts:digminlen=5:digmaxlen=7

This example provisions the response parameter and response format:

chg-aiqopts:respar=rtdigits:resfmt=pfx

Dependencies

The ANSI41 AIQ feature must be enabled before this command can be entered.

The AIQOPTS table is corrupt or cannot be found.

The pfx and trigtype parameters must be specified together in the command.

The value specified for the digminlen parameter must be less than or equal to the value specified for the digmaxlen parameter.

A maximum of 20 trigtype - pfx  entries can be specified in the AIQOPTS table.

A pfx - trigtype pair must be specified with a supported value for the trigtype parameter before the pfx=none parameter can be specified.

Notes

If the same value is specified for the digminlen and digmaxlen parameters, then only MSUs with dialed digits of the specified length are accepted for processing.

The value of the Digits (Dialed) length must be between the values specified for the digminlen and digmaxlen parameters.

A maximum of 20 pfx - trigtype pairs can be specified.

Table 4-1 lists the decimal value and mnemonic for each TRIGTYPE parameter value.

Table 4-1 TRIGTYPE Parameter Values

Decimal Value Mnemonic Decimal Value Mnemonic

0

Unspecified.

24

Local_Call.

1

All_Calls.

25

Local_Toll_Call.

2

Double_Introducing_Star.

26

Non-Local_Toll_Call

3

Single_Introducing_Star.

27

World_Zone_Call.

4

Reserved [for Home_System_Feature_ Code]

28

International_Call.

5

Double_Introducing_Pound.

29

Unrecognized_Number.

6

Single_Introducing_Pound.

30

Prior_Agreement.

7

Revertive_Call.

31

Specific_called_Party_ Digit_String.

8

0_Digit.

32

Mobile_Termination.

9

1_Digit.

33

Advanced_Termination.

10

2_Digit.

34

Location.

11

3_Digit.

35-63

Reserved. Treat a reserved value the same as value 0, Unspecified.

12

4_Digit.

64

Terminating_Resource_ Available.

13

5_Digit.

65

T_Busy.

14

6_Digit.

66

T_No_Answer.

15

7_Digit.

67

T_No_Page_Response.

16

8_Digit.

68

T_Unroutable.

17

9_Digit.

69-219

Reserved. Treat a reserved value the same as value 0, Unspecified.

18

10_Digit.

220

Reserved for TDP-R DP value.

19

11_Digit.

221

Reserved for TDP-N DP value.

20

12_Digit.

222

Reserved for EDP-R DP value.

21

13_Digit.

223

Reserved for EDP-N DP value.

22

14_Digit.

224-255

Reserved for TIA-41 protocol extension. If unknown, treat the same as value 0, Unspecified.

23

15_Digit.

Output

chg-aiqopts:trigtype=2:pfx=65432:respar=rtdigits:tcaperr=135

    tekelecstp 09-12-03 12:40:16 EST  EAGLE 42.0.0
    CHG-AIQOPTS: MASP A - COMPLTD 
;