4.35 chg-aiqopts
Use this command to provision AIQ specific data. This command updates the AIQOPTS table.
Parameters
- digmaxlen (optional)
- Maximum Length of Digit String. The maximum length of a digit string that is considered valid in the Digits (Dialed) field of an AnalyzedInformation query.
- digminlen (optional)
- Minimum Length of Digit String. The minimum length of a digit string that is considered valid in the Digits (Dialed) field of an AnalyzedInformation query.
- pfx (optional)
- Digit String. The digit string associated with a Trigger Type (value of trigtype parameter). The value specified for the pfx parameter is encoded in the response message.
- resfmt (optional)
- Response format. The format of outgoing routing digits in the AnalyzedInformation response message.
- respar (optional)
-
Response Digits. The TCAP field used to encode the AnalyzedInformation response message.
- tcaperr (optional)
-
TCAP Error Code. The TCAP error code used in a Return Error response.
- Range:
- 129 - 255
- 129—UnrecognizedMIN
- 130—UnrecognizedESN
- 131—MIN/HLR Mismatch
- 132—OperationSequenceProblem
- 133—ResourceShortage
- 134—OperationNotSupported
- 135—TrunkUnavailable
- 136—ParameterError
- 137—SystemFailure
- 138—UnrecognizedParameterValue
- 139—FeatureInactive
- 140—MissingParameter
- 141-239—Reserved
- 240-255—Reserved for Protocol Extension
- Default:
- No change to the current value
- System Default:
- 138
- trigtype (optional)
-
TriggerType Value. An individual trigger used to specify an association between a trigger and a corresponding address digit string (value of pfx parameter).
A maximum of 20 trigtype - pfx entries are supported. The pfx digit string corresponding to the specified Trigger Type present in the Incoming AnalyzedInfo Query is encoded in the Response message.
- Range:
- 0 - 255
Table 4-1 lists the mnemonic for each TRIGTYPE decimal value.
Example
This example specifies the provisioning of a Trigger Type – Prefix string pair:
chg-aiqopts:trigtype=2:pfx=65432This example deletes an already provisioned Trigger Type:
chg-aiqopts:trigtype=2:pfx=noneThis example specifies the digminlen-digmaxlen range (5-7):
chg-aiqopts:digminlen=5:digmaxlen=7This example provisions the response parameter and response format:
chg-aiqopts:respar=rtdigits:resfmt=pfxDependencies
The ANSI41 AIQ feature must be enabled before this command can be entered.
The AIQOPTS table is corrupt or cannot be found.
The pfx and trigtype parameters must be specified together in the command.
The value specified for the digminlen parameter must be less than or equal to the value specified for the digmaxlen parameter.
A maximum of 20 trigtype - pfx entries can be specified in the AIQOPTS table.
A pfx - trigtype pair must be specified with a supported value for the trigtype parameter before the pfx=none parameter can be specified.
Notes
If the same value is specified for the digminlen and digmaxlen parameters, then only MSUs with dialed digits of the specified length are accepted for processing.
The value of the Digits (Dialed) length must be between the values specified for the digminlen and digmaxlen parameters.
A maximum of 20 pfx - trigtype
pairs can be specified.
Table 4-1 lists the decimal value and mnemonic for each TRIGTYPE parameter value.
Table 4-1 TRIGTYPE Parameter Values
Decimal Value | Mnemonic | Decimal Value | Mnemonic |
---|---|---|---|
0 |
Unspecified. |
24 |
Local_Call. |
1 |
All_Calls. |
25 |
Local_Toll_Call. |
2 |
Double_Introducing_Star. |
26 |
Non-Local_Toll_Call |
3 |
Single_Introducing_Star. |
27 |
World_Zone_Call. |
4 |
Reserved [for Home_System_Feature_ Code] |
28 |
International_Call. |
5 |
Double_Introducing_Pound. |
29 |
Unrecognized_Number. |
6 |
Single_Introducing_Pound. |
30 |
Prior_Agreement. |
7 |
Revertive_Call. |
31 |
Specific_called_Party_ Digit_String. |
8 |
0_Digit. |
32 |
Mobile_Termination. |
9 |
1_Digit. |
33 |
Advanced_Termination. |
10 |
2_Digit. |
34 |
Location. |
11 |
3_Digit. |
35-63 |
Reserved. Treat a reserved value the same as value 0, Unspecified. |
12 |
4_Digit. |
64 |
Terminating_Resource_ Available. |
13 |
5_Digit. |
65 |
T_Busy. |
14 |
6_Digit. |
66 |
T_No_Answer. |
15 |
7_Digit. |
67 |
T_No_Page_Response. |
16 |
8_Digit. |
68 |
T_Unroutable. |
17 |
9_Digit. |
69-219 |
Reserved. Treat a reserved value the same as value 0, Unspecified. |
18 |
10_Digit. |
220 |
Reserved for TDP-R DP value. |
19 |
11_Digit. |
221 |
Reserved for TDP-N DP value. |
20 |
12_Digit. |
222 |
Reserved for EDP-R DP value. |
21 |
13_Digit. |
223 |
Reserved for EDP-N DP value. |
22 |
14_Digit. |
224-255 |
Reserved for TIA-41 protocol extension. If unknown, treat the same as value 0, Unspecified. |
23 |
15_Digit. |
Output
chg-aiqopts:trigtype=2:pfx=65432:respar=rtdigits:tcaperr=135
tekelecstp 09-12-03 12:40:16 EST EAGLE 42.0.0
CHG-AIQOPTS: MASP A - COMPLTD
;