4.139 chg-slt

Use this command to change the fields of a signaling link test message (SLTM) record in the SLTM table.

Parameters

sltset (mandatory)
Signaling link test message record number in the SLTM table.
Range:
1 - 20
enabled (optional)
Enables the signaling link test message.
Range:
on
off
Default:
No change to the current value
mode (optional)
SLTM mode to be used when sending test messages.
Range:
special
All SLTMs generated by the links in the linkset associated with this SLTM record are designated “special” maintenance messages.
regular
All SLTMs generated by the links in the linkset associated with this SLTM record are designated “regular” maintenance messages.
Default:
No change to the current value
pattern (optional)
Test pattern to be sent with a signaling link test message.
Range:
aayyyyyyyyyyyyyyyyyyyyyyyyyyyy

2 to 30 alphanumeric characters; valid characters are 0-9, a-f, A-F

An even number of characters must be used in the pattern. The first two characters of the pattern must be letters.

Default:
No change to the current value
t1 (optional)
Timer 1. The amount of time, in milliseconds, to wait after an SLTM test fails before running the SLTM test again.
Range:
4000 - 12000
Default:
No change to the current value
t2 (optional)
Timer 2. The amount of time, in milliseconds, that should pass between running SLTM tests for a normally functioning signaling link.
Range:
30000 - 90000
Default:
No change to the current value

Example

chg-slt:sltset=1:t1=4000:t2=39000:enabled=off:pattern=aabbccdd

Dependencies

The value of t1 should be greater than the level 3 timer t6 . The level 3 timer t6 can be 100 - 2000 milliseconds. Enter the rtrv-l3t command to verify the value of the level 3 timer t6.

Notes

None

Output

chg-slt:sltset=1:t1=4000:t2=39000:enabled=off:pattern=aabbccdd

    rlghncxa03w 04-01-07 00:21:41 EST  EAGLE 31.3.0
    CHG-SLT: MASP A - COMPLTD 
;