4.227 dlt-lbp
Use this command to delete one or all far-end loopback points maintained in the Link Fault Sectionalization table for testing data signaling link elements in a single CCS7 transmission path.
Parameters
- link (mandatory)
- SS7 signaling link. The SS7 signaling link that is to be tested.
- Synonym:
- port
- Range:
- a, b, a1 - a31, b1 - b31
Not all card types support all link parameter values.
See Table A-1 for valid link parameter range values for each type of card that can have assigned signaling link ports.
- loc (mandatory)
- Card location. The unique identifier of the card containing the signaling link to be used for loopback point testing.
- Range:
- 1101 - 1108, 1111 - 1112, 1201 - 1208, 1211 - 1218, 1301 - 1308, 1311 - 1318, 2101 - 2108, 2111 - 2118, 2201 - 2208, 2211 - 2218, 2301 - 2308, 2311 - 2318, 3101 - 3108, 3111 - 3118, 3201 - 3208, 3211 - 3218, 3301 - 3308, 3311 - 3318, 4101 - 4108, 4111 - 4118, 4201 - 4208, 4211 - 4218, 4301 - 4308, 4311 - 4318, 5101 - 5108, 5111 - 5118, 5201 - 5208, 5211 - 5218, 5301 - 5308, 5311 - 5318, 6101 - 6108, 6111 - 6118
Example
dlt-lbp:loc=1101:link=a:lbp=1
dlt-lbp:loc=1101:link=a:all=yes
Dependencies
At least one optional parameter must be specified.
The lbp parameter and the all parameter cannot be specified together in the command.
The Link Fault Sectionalization (LFS) feature must be on before this command can be entered.
The loopback point (LBP) must have been previously defined.
The card location indicated by the loc parameter must indicate an E5-E1T1-B card, provisioned with the LIMT1 card type, with either the SS7ANSI or CCS7ITU application.
The card location specified in the loc parameter must be equipped.
The card location specified in the loc parameter cannot be reserved by the system.
The Link Fault Sectionalization database Loopback Point (LBP) table is not accessible.
Notes
None
Output
dlt-lbp:loc=1101:link=a:lbp=1
rlghncxa03w 05-02-17 15:35:05 EST EAGLE5 33.0.0
DLT-LBP: MASP A - COMPLTD
;