4.90 chg-lbp

Use this command to change a far-end loopback point’s attribute values maintained in the link fault sectionalization table.

Parameters

lbp (mandatory)
Loopback point ID. This parameter identifies a far-end loopback point that lies along an SS7 signaling link path between the STP and the target device (up to and including the target device).
Range:
1 - 32
link (mandatory)
SS7 signaling links. The SS7 signaling link to be tested.
Synonym:
port
Range:
a, b, a1 - a31, b1 - b31

Not all card types support all link parameter values.

See Table A-1  for valid link parameter range values for each type of card that can have assigned signaling links.

loc (mandatory)
Card location. The unique identifier of a specific application subsystem located in the STP.
Range:
1101 - 1108, 1111 - 1112, 1201 - 1208, 1211 - 1218, 1301 - 1308, 1311 - 1318, 2101 - 2108, 2111 - 2118, 2201 - 2208, 2211 - 2218, 2301 - 2308, 2311 - 2318, 3101 - 3108, 3111 - 3118, 3201 - 3208, 3211 - 3218, 3301 - 3308, 3311 - 3318, 4101 - 4108, 4111 - 4118, 4201 - 4208, 4211 - 4218, 4301 - 4308, 4311 - 4318, 5101 - 5108, 5111 - 5118, 5201 - 5208, 5211 - 5218, 5301 - 5308, 5311 - 5318, 6101 - 6108, 6111 - 6118
clli (optional)
Common Language Location Identifier (CLLI) code. This parameter specifies the CLLI or other mnemonic identifier used to refer to the given loopback point.
Range:
ayyyyyyyyyy

1 alphabetic character followed by up to 23 alphanumeric characters

Default:
No change to the current value
lfst (optional)
Link fault sectionalization test. The type of link fault sectionalization loopback test to be performed.
Range:
llt
latching loopback test
nlt
nonlatching loopback test
rep (optional)
Repetition count. The number of link elements of the same type (not including the target device) that lie between the STP and the link element to be tested.
Range:
0 - 31
Default:
No change unless:

0—The link element to be looped back for testing is NEI (rle=nei is specified)

0—The type of link fault sectionalization test is NLT (lfst=nlt is specified)

0—The new remote link element is the first loopback point of the link to be tested

1–30—Next sequential number for subsequent loopback points of the link to be tested

rle (optional)
Remote link element. The link element to be looped back for testing.
Range:
ds0
ocu
csu
dsu
nei
Default:
No change to the rle value

Example

chg-lbp:loc=1101:link=a:lbp=1:rle=ds0:lfst=llt

Dependencies

The Link Fault Sectionalization (LFS) feature must be on before using this command.

At least one optional parameter must be specified.

The card location specified in the loc parameter cannot be reserved by the system.

The card location (loc parameter) must identify a provisioned E5-E1T1-B card, provisioned with the LIMT1 card type, configured with either the SS7ANSI or CCS7ITU application.

The CLLI cannot be a reserved word.

The rep parameter value that is specified for this loopback point (LBP) must be greater than the rep parameter value of any previously defined LBP and less than the rep parameter value of any subsequently defined LBP.

The rep parameter must be specified if the default value is a duplicate of the rep parameter value of any previously defined loopback point.

The LBP must have been previously defined.

The rep parameter can be specified only if the lfst=llt parameter is specified.

If the rle=nei parameter is specified, the rep=0 parameter must be specified.

The rle=ds0 or the rle=nei parameter cannot be specified if the lfst=nlt parameter is specified. The DS0 and Network Element Interface (NEI) link elements do not support non-latching loopbacks.

For each SS7 signaling link, you can define only one loopback point with rle=nei specified; and that loopback point must be the terminating SS7 signaling link component.

For each SS7 signaling link, the loopback point with rle=nei specified must be the terminating SS7 signaling link component.

The card location specified in the loc parameter must be equipped.

The Link Fault Sectionalization database Loopback Point (LBP) table is not accessible.

Notes

None

Output

chg-lbp:loc=1101:port=a:lbp=1:rle=ds0:lfst=llt

    rlghncxa03w 05-01-17 15:35:05 EST  EAGLE5 33.0.0
    CHG-LBP: MASP A - COMPLTD 
;