4.457 rtrv-atm-lps

Use this command to display the parameter values for the ATM link parameter sets in the database configured with the chg-atm-lps command, along with the non-configurable ATM parameters.

Parameters

lpset (optional)
The ATM link parameter set to be displayed.
Range:
1 - 30
Default:
All ATM link parameter sets are displayed

Example

rtrv-atm-lps:lpset=5

rtrv-atm-lps

Dependencies

None

Notes

None

Output

Note:

Dashes (--) in the FC NR and FC BC fields indicate that this implementation is not supported on ATM high-speed signaling links.
rtrv-atm-lps:lpset=5

    rlghncxa03w 04-01-04 08:40:18 EST  EAGLE 31.3.0
    ATM LINK PARAMETER SET TIMERS AND PARAMETERS (TIMERS IN SECONDS)
                                    SSCOP PARAMETERS
                                  TMR  TMR     TMR    TMR    TMR
    LPSET  MAXCC  MAXPD  MAXSTAT  CC   KALIVE  NORSP  POLL   IDLE
    5      4      500    67       0.2  0.125   1.5    0.150  0.125

                                    SSCF-NNI PARAMETERS
           TMRT1  TMRT2  TMRT3     N1
           05.0   120.0  0.000925  64552

                                    SAAL PARAMETERS
           MAX  TMR   TNRNO  TMR    N    TMR
           NRP  SREC  CRED   ERM    BLK  PROV
           1    3600  1.5    0.125  3    0600.0

                              NONCONFIGURABLE PARAMETERS
           SDU   UU       FC  FC
           SIZE  SIZE  N  NR  BC  TSUP  TLOSS  ERMSM  THRES
           272   4     9  --  --  120   1.3    0.1    0.244 
;
rtrv-atm-lps

    rlghncxa03w 04-01-04 08:40:18 EST  EAGLE 31.3.0

                                    SSCOP PARAMETERS
                                  TMR  TMR     TMR    TMR    TMR
    LPSET  MAXCC  MAXPD  MAXSTAT  CC   KALIVE  NORSP  POLL   IDLE
    1      4      500    67       0.2  0.125   1.5    0.150  0.125
    2      4      500    67       0.2  0.125   1.5    0.150  0.125
    3      4      500    67       0.2  0.125   1.5    0.150  0.125
    4      4      500    67       0.2  0.125   1.5    0.150  0.125
    5      4      500    67       0.2  0.125   1.5    0.150  0.125
    6      4      500    67       0.2  0.125   1.5    0.150  0.125
    7      4      500    67       0.2  0.125   1.5    0.150  0.125
    8      4      500    67       0.2  0.125   1.5    0.150  0.125
    9      4      500    67       0.2  0.125   1.5    0.150  0.125
    10     4      500    67       0.2  0.125   1.5    0.150  0.125
    11     4      500    67       0.2  0.125   1.5    0.150  0.125
    12     4      500    67       0.2  0.125   1.5    0.150  0.125
    13     4      500    67       0.2  0.125   1.5    0.150  0.125
    14     4      500    67       0.2  0.125   1.5    0.150  0.125
    15     4      500    67       0.2  0.125   1.5    0.150  0.125
    16     4      500    67       0.2  0.125   1.5    0.150  0.125
    17     4      500    67       0.2  0.125   1.5    0.150  0.125
    18     4      500    67       0.2  0.125   1.5    0.150  0.125
    19     4      500    67       0.2  0.125   1.5    0.150  0.125
    20     4      500    67       0.2  0.1     1.5    0.1    0.1

                                    SSCF-NNI PARAMETERS
    LPSET  TMRT1  TMRT2  TMRT3     N1
    1      05.0   015.0  0.000925  64552
    2      05.0   120.0  0.000925  64552
    3      05.0   120.0  0.000925  64552
    4      15.0   010.0  0.000925  64552
    5      05.0   120.0  0.000925  500
    6      05.0   015.0  0.000925  64552
    7      05.0   120.0  0.000925  64552
    8      05.0   120.0  0.000925  64552
    9      15.0   010.0  0.000925  64552
    10     05.0   015.0  0.000925  64552
    11     05.0   120.0  0.000925  64552
    12     05.0   120.0  0.000925  64552
    13     15.0   010.0  0.000925  64552
    14     05.0   015.0  0.000925  64552
    15     05.0   120.0  0.000925  64552
    16     05.0   120.0  0.000925  64552
    17     15.0   010.0  0.000925  64552
    18     05.0   015.0  0.000925  64552
    19     05.0   120.0  0.000925  64552
    20     05.0   120.0  0.000925  64552

                                    SAAL PARAMETERS
    LPSET  MAX  TMR   TNRNO  TMR    N    TMR
           NRP  SREC  CRED   ERM    BLK  PROV
    1     1    3600  1.5    0.125  3    1200.0
    2     1    3600  1.5    0.125  3    1000.0
    3     1    60    1.5    0.125  3    0600.0
    4     1    3600  1.5    0.125  3    0600.0
    5     1    3600  1.5    0.125  3    0600.0
    6     1    3600  1.5    0.125  3    1200.0
     7     1    3600  1.5    0.125  3    1000.0
    8     1    60    1.5    0.125  3    0600.0
    9     1    3600  1.5    0.125  3    0600.0
    10    1    3600  1.5    0.125  3    0600.0
    11    1    3600  1.5    0.125  3    1200.0
    12    1    3600  1.5    0.125  3    1000.0
    13    1    60    1.5    0.125  3    0600.0
    14    1    3600  1.5    0.125  3    0600.0
    15    1    3600  1.5    0.125  3    0600.0
    16    1    3600  1.5    0.125  3    1200.0
    17    1    3600  1.5    0.125  3    1000.0
    18    1    60    1.5    0.125  3    0600.0
    19    1    3600  1.5    0.125  3    0600.0
    20    1    3600  1.5    0.125  3    0600.0

                              NONCONFIGURABLE PARAMETERS
           SDU   UU       FC  FC 
           SIZE  SIZE  N  NR  BC  TSUP  TLOSS  ERMSM  THRES
           272   4     9  --  --  120   1.3    0.1    0.244 
;
rtrv-atm-lps

    tekelecstp 04-01-05 08:40:18 EST  EAGLE 31.3.0
    ATM LINK PARAMETER SET TIMERS AND PARAMETERS (TIMERS IN SECONDS)

                                  SSCOP PARAMETERS         
                                  TMR  TMR     TMR    TMR    TMR
    LPSET  MAXCC  MAXPD  MAXSTAT  CC   KALIVE  NORSP  POLL   IDLE  
    1      4      500    67       0.2  0.125   1.5    0.150  0.125
.
. 
    20     4      500    67       0.2  0.1     1.5    0.1   0.1 
    21     4      500    67       0.2  0.1     1.5    0.1   0.1.
.
    30     4      500    67       0.2  0.1     1.5    0.1   0.1 

                                   SSCF-NNI PARAMETERS 
    LPSET  TMRT1  TMRT2  TMRT3     N1
    1      05.0   015.0  0.000925  64552
.
.
    20     5       30    0.000925  64552
    21     5      120    0.000925   1000
.
.
    30     5      120    0.000925  64552

                                 SAAL PARAMETERS 
    LPSET  MAX  TMR   TNRNO  TMR    N    TMR     
           NRP  SREC  CRED   ERM    BLK  PROV  
     1     1    3600  1.5    0.125  3    1200.0
.
.
     20    1    3600  1.5    0.125  3    0600.0
     21    0    3600  1.5    0.125  3    1200.0
.
.
     30    0    3600  1.5    0.125  3    0600.0

                                  NONCONFIGURABLE PARAMETERS
           SDU   UU       FC  FC 
           SIZE  SIZE  N  NR  BC  TSUP  TLOSS  ERMSM  THRES
           272   4     9  --  --  120   1.3    0.1    0.244 
;

Legend

  • LPSET—Link parameter set being changed. The system default value for this parameter is 1 for ANSI and, 21 for ITU.
  • ACTION—Copy a set of ATM signaling link parameters from one parameter set to another.
  • SCRLPSET—ATM signaling link parameter set used as a source for the action=copy parameter.
  • MAXCC—Maximum number of transmissions of a BGN, END, ER, or RS PDU
  • MAXPD—Maximum number of SD PDUs that can be sent before a POLL is sent
  • MAXSTAT—Maximum number of list elements in a STAT PDU
  • TMRCC—Timer, in seconds, used during the connection phase to guard against unacknowledged BGN, END, ER or RS PDUs
  • TMRKALIVE—Timer, in seconds, used during the transient phase when no SD PDUs are being sent to keep connection up
  • TMRNOSP—Timer, in seconds, used to check that STAT PDUs are arriving often enough
  • TMRPOLL—Timer, in seconds, used to guarantee that POLL PDUs are sent often enough
  • TMRIDLE—Timer, in seconds, used during the idle phase when no SD PDUs are being sent to limit time in the idle phase
  • TMRT1—Time, in seconds, between a link release action and the next link reestablish action during alignment
  • TMRT2—Total time, in seconds, that SSCF will attempt alignment
  • TMRT3—Time, in seconds, between proving PDUs
  • N1—Number of PDUs sent during proving
  • MAXNRP—Maximum number of retransmitted PDUs during proving
  • TMRSREC—The timer, in seconds, used to prohibit closely spaced SSCOP recoveries from occurring.
  • TMRNOCRED—The timer, in seconds, used when the no credit exists and PDUs are available to be sent.
  • TMRERM—The error rate monitor interval, in seconds.
  • NBLK—The number of monitoring intervals per block.
  • TMRPROV—The timer, in seconds, used to monitor the status of a link after it is placed into service.
  • SDU SIZE—The SSCOP SDU size (set to 272 octets).
  • UU SIZE—The SCOP UU size (set to 4 octets).
  • N—The monitoring intervals spanning a.4 second error event (set to 9).
  • FC NR—The fixed credit increment value.
  • FC BC—The fixed credit allocation frequency.
  • TSUP—The superblock timer for layer management, in seconds.
  • TLOSS—The loss timer for layer management, in seconds.
  • ERMSM—The error rate monitor smoothing factor.
  • THRES—The error rate monitor threshold.