Billable Charge Read Details Upload Staging Layout
You must create a billable charge read details upload record for each read detail to be uploaded. The name of this table is CI_BCHG_UP_READ. The following table describes each column on this table. Refer to "pass through" charges for more information about how this type of information is used.
| 
 Column Name  | 
 Length  | 
 Req'd  | 
 Data Type  | 
 Comments  | 
| 
 BCHG_UP_ID  | 
 30  | 
 Y  | 
 Char  | 
 This is the foreign key to the billable charge upload staging record.  | 
| 
 SP_ID  | 
 10  | 
 Y  | 
 Char  | 
 Note, if USAGE_FLG is calculation, you can set this field to 0 if you do not know the SP ID. The only thing that's important is that the combination of BCHG_UP_ID, SP_ID and SEQNO are unique.  | 
| 
 SEQNO  | 
 5  | 
 Y  | 
 Number  | 
 This should be a value greater than zero. See SP_ID comment for more information. This is typically the sequence number of the register on the meter.  | 
| 
 END_READ_DTTM  | 
 26  | 
 Y  | 
 DateTime  | 
 This is the date and time of the end read  | 
| 
 END_REG_READ_ID  | 
 12  | 
 N  | 
 Char  | 
 This field must reference an existing register read ID if USAGE_FLG is anything other than a calculation.  | 
| 
 END_REG_READING  | 
 9.6  | 
 Y  | 
 Number  | 
 This is the reading of the end read.  | 
| 
 FINAL_REG_QTY  | 
 12.6  | 
 Y  | 
 Number  | 
 This is the final amount of the reading (this is the amount of billable consumption the read detail contributed to the entire billed consumption).  | 
| 
 FINAL_SQI  | 
 8  | 
 N  | 
 Char  | 
 The service quantity identifier of the FINAL_REG_QTY. If specified, it must reference a valid value on CI_SQI. Note, at least one of the following fields should be specified: FINAL_SQI, FINAL_UOM_CD.  | 
| 
 FINAL_TOU_CD  | 
 8  | 
 N  | 
 Char  | 
 The time-of-use code of the FINAL_REG_QTY. If specified, it must reference a valid value on CI_TOU.  | 
| 
 FINAL_UOM_CD  | 
 4  | 
 N  | 
 Char  | 
 The unit of measure of the FINAL_REG_QTY. If specified, it must reference a valid value on CI_UOM. Note, at least one of the following fields should be specified: FINAL_SQI, FINAL_UOM_CD.  | 
| 
 HOW_TO_USE_FLG  | 
 2  | 
 Y  | 
 Char  | 
 See the field description for valid values (CI_BCHG_UP_READ).  | 
| 
 MSR_PEAK_QTY_SW  | 
 1  | 
 Y  | 
 Char  | 
 Y or N  | 
| 
 MSR_QTY  | 
 12.6  | 
 Y  | 
 Number  | 
 This is the difference between END_REG_READING and START_REG_READING for subtractive registers.  | 
| 
 REG_CONST  | 
 6.6  | 
 Y  | 
 Number  | 
 This is the register's constant (the value used to adjust the measured quantity due to something associated with the physical meter). Set this to a value of 1 if it is not known.  | 
| 
 SQI_CD  | 
 30  | 
 N  | 
 Varchar  | 
 The service quantity identifier of END_REG_READING and START_REG_READING. If specified, it must reference a valid value on CI_SQI. Note, at least one of the following fields should be specified: SQI_CD, TOU_CD, UOM_CD.  | 
| 
 START_READ_DTTM  | 
 26  | 
 Y  | 
 DateTime  | 
 This is the date and time of the start reading.  | 
| 
 START_REG_READ_ID  | 
 12  | 
 Y  | 
 Char  | 
 This field must reference an existing register read ID if USAGE_FLG is anything other than a calculation.  | 
| 
 START_REG_READING  | 
 9.6  | 
 Y  | 
 Number  | 
 This is the reading of the start read.  | 
| 
 TOU_CD  | 
 30  | 
 N  | 
 Char  | 
 The time-of-use code of END_REG_READING and START_REG_READING. If specified, it must reference a valid value on CI_TOU.  | 
| 
 UOM_CD  | 
 30  | 
 Y  | 
 Char  | 
 The unit of measure of END_REG_READING and START_REG_READING.  | 
| 
 USAGE_FLG  | 
 2  | 
 Y  | 
 Char  | 
 See the field description for valid values (CI_BCHG_UP_READ).  | 
| 
 USE_PCT  | 
 3  | 
 Y  | 
 Number  | 
 This is the percentage of the consumption that was billed (this will typically be 100).  | 