The Itron OpenWay Adapter base package includes the following communication business objects:
| 
 Business Object Name  | 
 Description  | 
|---|---|
| 
 D8-AddMeterDefinitions  | 
 Itron - Add Meter Definition (Commission)  | 
| 
 D8-DeregisterMeter  | 
 Itron - Deregister Meter (Decommission)  | 
| 
 D8-DetectLoadSideVoltageByMtr  | 
 Itron - Detect Load Side Voltage  | 
| 
 D8-DetLoadSideVoltageMtrRslt  | 
 Itron - Detect Load Side Voltage Result  | 
| 
 D8-DisconnectMeter  | 
 Itron - Disconnect Meter (Remote Disconnect)  | 
| 
 D8-DisconnectMeterResult  | 
 Itron - Disconnect Meter Result  | 
| 
 D8-PingByEndpoints  | 
 Itron - Ping By Endpoints (Device Status Check)  | 
| 
 D8-PingByEndpointsMDResponse  | 
 Itron - Multi-Device Ping Response  | 
| 
 D8-PingByEndpointsMultiDevice  | 
 Itron - Ping By Endpoints Multi-Device  | 
| 
 D8-PingByEndpointsResponse  | 
 Itron - Ping By Endpoints Response  | 
| 
 D8-ReadDisconStateByMtr  | 
 Itron - Read Disconnect State  | 
| 
 D8-ReadDisconStateMtrRslt  | 
 Itron - Read Disconnect State Result  | 
| 
 D8-ReadInterval  | 
 Itron - Contingency Read (Interval)  | 
| 
 D8-ReadResult  | 
 Itron - Contingency Read Result  | 
| 
 D8-ReadScalar  | 
 Itron - Contingency Read (Scalar)  | 
| 
 D8-ReconnectMeter  | 
 Itron - Reconnect Meter (Remote Connect)  | 
| 
 D8-ReconnectMeterResult  | 
 Itron - Reconnect Meter Result  | 
Itron OpenWay Event Data Mapping
The Itron OpenWay event file format maps as follows into the business object, D1-DeviceEventMappingLookup:
| 
 Itron OpenWay Flat File Field  | 
 Device Event Seeder BO Element  | 
 Comments  | 
|---|---|---|
| 
 Transaction ID (from Header record)  | 
 External Source Identifier  | 
 This is the file name.  | 
| 
 Device Identifier  | 
 External Device Identifier  | 
|
| 
 Event Name  | 
 External Event Name  | 
|
| 
 Event Creation Date/Time  | 
 Event Date/Time  | 
|
| 
 Device Type  | 
 External Device Type  | 
 This element has no real bearing on the device type within MDM/SGG. Its valid values include (although the element itself is free-form): Meter Collector Router  | 
| 
 Service Location ID  | 
 External Service Location ID  | 
|
| 
 Communication Module Serial Number  | 
 External Communication Module Identifier  | 
|
| 
 Event Category ID  | 
 External Event Category  | 
|
| 
 Event Severity  | 
 External Event Severity  | 
 Valid values include (although the element itself is free-form): Alert Information  | 
| 
 Status Value  | 
 External Status Value  | 
 This represents additional information that relates to the event itself.  | 
| 
 Status Date/Time  | 