Previous Topic

Next Topic

Book Contents

Clintrial rules that use data from more than one panel

In the Clintrial software, a query can be based on data that resides in two different panels. CIS uses single panel verification; that is, it only fires verification on the panel where the data has changed. This verification method means that if a Clintrial rule on one panel uses data that resides on a different panel, the corresponding query that the user resolves in the InForm software (by correcting the data on the panel that does not contain the rule) will have no effect on the resolution of the query in the second Clintrial panel where the rule is attached.

This issue is evident if you resolve a query in the InForm software by changing the data, but after a subsequent synchronization, the query in InForm continues to be unresolved. To determine whether this situations is caused by data in the Clintrial software, you must use the Clintrial Manage and Resolve modules to revalidate the panels. If the query is resolved after revalidating, the rule is attached to the panel where no data changed.