Configuring Silver Spring Networks Extendable Lookups

Note: This section applies to both middleware and native implementations of the Smart Grid Gateway Adapter for Silver Spring Networks.

This section outlines some of the extendable lookups that must be configured for use with the Silver Spring Networks adapter. Refer to the Oracle Utilities Application Framework documentation for more information about working with extendable lookups.

Device Event Mapping

The Device Event Mapping extendable lookup is used to determine which type of device event business object to instantiate when receiving device events from the head-end system. Each value defined for the Device Event Mapping extendable lookup should include the following:

  • Head-End System Event Name: The event name used by the head-end system.

  • Description: A description of the device event.

  • Status: The status of the lookup value (can be Active or Inactive).

  • Standard Event Name: The standard event name for device events of this type, from the “Standard Event Name” extendable lookup.

UOM Code to Standard UOM Mapping

Usage received from a utility’s head-end system may use utility-specific unit of measures (UOMs). These custom UOMs must be mapped to standard UOM codes. The UOM Code to Standard UOM Mapping extendable lookup is used for this purpose. Each value defined for the UOM Code to Standard UOM Mapping extendable lookup should include the following:

  • Head-End Unit of Measure: The unit of measure code used by the head-end system.

  • Description: A description of the unit of measure code.

  • Status: The status of the lookup value (can be Active or Inactive).

  • Unit of Measure: The unit of measure defined in the system.

Interval Status Code to Condition Mapping

Interval usage received from the Silver Spring Networks UtilityIQ can include Silver Spring Networks interval status codes that indicate the status or condition of the interval value. These interval status codes must be mapped to standard condition codes in the system. The Silver Spring Networks Interval Status Code to Condition Mapping extendable lookup is used to determine how to map Silver Spring Networks interval status codes to standard status codes when receiving usage from the Silver Spring Networks UtilityIQ.

Each value defined for the Silver Spring Networks Interval Status Code to Condition Mapping extendable lookup should include the following:

  • Interval Status: The Silver Spring Networks interval status code

  • Description: A description of the interval status code.

  • Status: The status of the lookup value (can be Active or Inactive)

  • Condition: The condition code to which the interval status code is to be mapped, from the Measurement Condition extendable lookup.

Other Extendable Lookups

Business Object Name

Description

D7-ActivationStatusLookup

SSN - Activation Status

D7-ChannelStatusLookup

SSN - Channel Status

D7-DataTimeZoneLookup

SSN - Data Time Zone

D7-DeviceStatusLookup

SSN - Device Status

D7-ExecutionStatusLookup

SSN - Execution Status

D7-HeadendSQILookup

SSN - Head-End SQI to Standard SQI

D7-HeadendTOULookup

SSN - Head-End TOU to Standard TOU

D7-IntervalStatusLookup

SSN - Interval Status

D7-MeterConnectionStatusLookup

SSN - Meter Connection Status

D7-MeterReadTypeLookup

SSN - Meter Read Type

D7-OldAdminStateNameLookup

SSN - Old Admin State Name

D7-PriorityLookup

SSN - Priority Status

D7-ProvisioningActionLookup

SSN - Provisioning Action

D7-ProvisioningCommandStatus

SSN - Provisioning Command Status

D7-ProvisioningDataType

SSN - Provisioning Data Type

D7-ReadModeLookup

SSN - Read Mode

D7-RegisterReadSourceLookup

SSN - Register Read Source

D7-RegisterStatusLookup

SSN - Register Status

D7-SSNVersionLookup

SSN - Version

D7-StatusFlagNameLookup

SSN - Status Flag Name