Importing an Existing Logical Drive Configuration (SPARC)
Instead of creating a logical drive, as described in Using the pcli Utility to Create a Bootable Drive (SPARC) , you might
need to import an existing logical drive (MegaRAID virtual disk) configuration from
a different MegaRAID controller. To import an existing configuration, complete the
procedures in this section.
To Import an Existing Logical Drive Configuration From a Different Controller
(SPARC)
Note -
Only MegaRAID logical drives can be imported; Integrated RAID (IR)
logical drives cannot be imported.
-
Use the /c0/fall show command to display any
foreign logical volumes which might exist.
Note -
A foreign logical volume isa logical volume created on a different
controller, and then the logical volume disks are moved to this
controller. Do not use foreign logical volumes without explicit
consent from the administrator of the foreign logical
volumes.
-
Use the
/c0/fforeign-logical-volume-number
import command to import the logical drive to the
HBA.
In the example below, the foreign logical volume,
2, is specified for importing.
{0} ok cli /c0/f2 import