Updating Oracle 3.84 TB NVMe SSD Software and Firmware
This section provides information on updating Oracle 3.84 TB NVMe SSD firmware and software.
Parent topic: Oracle 3.84 TB NVMe SSD Product Information
Accessing Software Updates and Firmware Downloads
Product patches, updates and firmware are available on My Oracle Support from the Patches and Updates tab.
These topics provide important information for updating Oracle 3.84 TB NVMe SSD software in supported servers:
- Download the Device Software Package
- Update the NVMe Storage Drive Firmware
- Verify Oracle 3.84 TB NVMe SSD Operation
Parent topic: Updating Oracle 3.84 TB NVMe SSD Software and Firmware
Download the Device Software Package
To find the device software package, access My Oracle Support and download the latest software package for Oracle 3.84 TB NVMe SSDs.
- Go to the My Oracle Support web site: https://support.oracle.com.
- Sign in to My Oracle Support.
-
At the top of the page, click the Patches &
Updates tab.
The Patch Search pane appears at the right of the screen.
-
Within the Search tab area, click Number/Name
or Bug Number (Simple).
The Search tab area appears with search fields.
- In the Product field, enter the patch number for Oracle 3.84 TB NVMe SSDs.
-
In the Release field, select a software release from the drop-down
list.
Expand the list to see all available software releases.
-
Click Search.
The Patch Advanced Search Results screen appears, listing the patches for the software release.
-
To select a patch for a software release, click the patch number next
to the software release version.
You can use the Shift key to select more than one patch.
A pop-up action panel appears. The panel contains several action options, including the ReadMe, Download, and Add to Plan options. For information about the Add to Plan option, click the associated button and select “Why use a plan?”.
- To review the ReadMe file for this patch, click ReadMe.
- To download the patch for the software release, click Download.
-
In the File Download dialog box, click the patch zip file name.
The patch for the software release downloads. The download is an archive zip file, which you must extract to find the directory containing the image.pkg file.
Parent topic: Accessing Software Updates and Firmware Downloads
Update the NVMe Storage Drive Firmware
-
Update your system to the latest software release.
-
Verify that the latest supported software release of Oracle Hardware Management Pack is installed on the host.
For CLI command instructions, refer to Oracle Hardware Management Pack documentation at https://docs.oracle.com/en/servers/management.html.
This procedure provides instructions to update Oracle 3.84 TB NVMe SSD NAND flash controller firmware on the host for supported Oracle Solaris and Linux operating systems. Oracle 3.84 TB NVMe SSD firmware is updated as a single package using Oracle Hardware Management Pack utility command-line interface (CLI) tools.
Note:
For detailed instructions on system software updates, refer to the server documentation.- Check 3.84 TB NVMe SSD User Guide for the latest firmware requirements.
-
Log in to the target system.
For detailed instructions, refer to the server installation guide. For example, to log in to the target system through SSH or through Oracle ILOM Remote System Console Plus, do one of the following:
-
If you are using an SSH client connection.
-
From a shell command line in a terminal window, establish an SSH connection to the server host.
Type: ssh root@hostname , where hostname can be the DNS name or the IP address for the server host.
-
Log in to the system using an account with root access.
-
Proceed to Step 3.
-
-
If you are using a remote system console, first refer to the server Administration Guide and then perform these steps.
To launch an Oracle ILOM Remote System Console Plus session, refer to Launching Remote KVMS Redirection Sessions in the server Administration Guide.
-
Establish a remote connection to the host console.
Start an Oracle ILOM serial console session, type:
-> start /HOST/console
Are you sure you want to start /HOST/console (y/n)? y
-
Ensure that the server is powered on and booted.
-
Access the operating system command-line interface.
You issue Oracle Hardware Management Pack commands from the operating system command-line interface.
-
-
-
Download and store any firmware image file updates on the server that
are required to support Oracle 3.84 TB NVMe SSDs.
- Download firmware image files from this location:
- Copy the downloaded firmware image files obtained to the target system root directory.
-
Identify all Oracle 3.84 TB NVMe SSD controller firmware versions in
the server.
- Type
#
fwupdate list controller.In the following examples, Oracle 3.84 TB NVMe SSD controllers
c0
toc11
are enumerated in the output returned by the above command.#
fwupdate list controller ================================================== CONTROLLER ================================================== ID Type Manufacturer Model Product Name FW Version ----------------------------------------------------------------------------- c0 NVMe Samsung 0xa824 SAMSUNG MZWLR7T6HALA-00AU3MPK94R5Q c1 NVMe Intel 0x0b60 INTEL SSDPF2KX076T9S 2CV1RC50 c2 HDC Intel 0xa182 0x4873 - c3 NVMe Intel 0x0b60 INTEL SSDPF2KX076T9S 2CV1RC50 c4 NVMe Intel 0x0b60 INTEL SSDPF2KX076T9S 2CV1RC50 c5 NVMe Intel 0x0b60 INTEL SSDPFCKE064T9S 2CV1RC30 c6 NVMe Intel 0x0b60 INTEL SSDPFCKE064T9S 2CV1RC30 c7 NVMe Intel 0x0b60 INTEL SSDPFCKE064T9S 2CV1RC50 c8 NVMe Intel 0x0b60 INTEL SSDPFCKE064T9S 2CV1RC50 c9 NVMe Intel 0x0b60 INTEL SSDPF2KX076T9S 2CV1RC50 c10 NVMe Intel 0x0b60 INTEL SSDPF2KX076T9S 2CV1RC50 c11 NVMe Intel 0x0b60 INTEL SSDPF2KX076T9S 2CV1RC50 -
Verify that the firmware package files that are installed in
Oracle 3.84 TB NVMe SSDs require updating.
To identify NVMe controllers that need updated firmware image files, view the
FW Version
column in the output from the fwdupdate list controller command.In the following example, Oracle 3.84 TB NVMe SSD controller
c5
andc6
shows firmware version2CV1RC30
, while the other NVMe controllers show firmware version2CV1RC50
.#
fwupdate list controller ================================================== CONTROLLER ================================================== ID Type Manufacturer Model Product Name FW Version ----------------------------------------------------------------------------- c0 NVMe Samsung 0xa824 SAMSUNG MZWLR7T6HALA-00AU3MPK94R5Q c1 NVMe Intel 0x0b60 INTEL SSDPF2KX076T9S 2CV1RC50 c2 HDC Intel 0xa182 0x4873 - c3 NVMe Intel 0x0b60 INTEL SSDPF2KX076T9S 2CV1RC50 c4 NVMe Intel 0x0b60 INTEL SSDPF2KX076T9S 2CV1RC50 c5 NVMe Intel 0x0b60 INTEL SSDPFCKE064T9S 2CV1RC30 c6 NVMe Intel 0x0b60 INTEL SSDPFCKE064T9S 2CV1RC30 c7 NVMe Intel 0x0b60 INTEL SSDPFCKE064T9S 2CV1RC50 c8 NVMe Intel 0x0b60 INTEL SSDPFCKE064T9S 2CV1RC50 c9 NVMe Intel 0x0b60 INTEL SSDPF2KX076T9S 2CV1RC50 c10 NVMe Intel 0x0b60 INTEL SSDPF2KX076T9S 2CV1RC50 c11 NVMe Intel 0x0b60 INTEL SSDPF2KX076T9S 2CV1RC50 -
View the Firmware Revision in the output from the
nvmeadm list -v command.
To identify NVMe controllers and current firmware versions type # nvmeadm list -v.
In the following example, controllers
SUNW-NVME-1
andSUNW-NVME-2
show firmware version2CV1R150
in the output returned by the above command.#
nvmeadm list -v SUNW-NVME-1 PCI Vendor ID: 0x144d Serial Number: S64TNE0N800033 Model Number: SAMSUNG MZWLR7T6HALA-00AU3 Firmware Revision: MPK94R5Q Number of Namespaces: 32 SUNW-NVME-2 .... PCI Vendor ID: 0x8086 Serial Number: PHAB011200LV7P6GGN Model Number: INTEL SSDPF2KX076T9S Firmware Revision: 2CV1RC50 Number of Namespaces: 128
- Type
-
Quiesce Oracle 3.84 TB NVMe SSD devices.
Before removing the card, manually quiesce I/O and device usage.
Caution:
System hang or data loss. Before updating device firmware, ensure that the device is quiesced and the following events are not occurring:-
The operating system is not accessing the disk (for example, the system boot disk).
-
An application is not accessing the disk (for example, a database application).
-
-
Update the selected Oracle 3.84 TB NVMe SSDs with the specified
firmware package.
The
fwupdate
command can update firmware for all similar devices in the system utilizing an XML metadata file. This method is called Automatic Mode and is the recommended method for upgrades.Note:
Alternately, if you determine that each device must be updated with a separatefwupdate
command, perform thefwupdate
Automatic Single Drive method, or thefwupdate
Manual method (if an XML metadata file is not available). For CLI command instructions, refer to Oracle Hardware Management Pack documentation at: https://docs.oracle.com/en/servers/management.html.-
Verify that an XML metadata file is available for the
server.
An XML metadata file must be included with the firmware update package to use Automatic Mode. Refer to the update package release notes for more information.
- To update device firmware on Oracle 3.84 TB NVMe SSDs, type
# fwupdate update controller -x metadata.xml
In the following example, controllers
c5
andc6
will be upgraded to firmware version2CV1R150
.#
fwupdate update controller -x metadata.xml The following components will be upgraded as shown: ========================================================== ID Priority Action Status Old Firmware Ver. Proposed Ver. New Firmware Ver. System Reboot -------------------------------------------------------------------------------------------------------------------- c5 1 Check FW Success 2CV1RC30 2CV1RC50 N/A None c6 1 Check FW Success 2CV1RC30 2CV1RC50 N/A None Do you wish to process all of the above component upgrades? [y/n]?If the current firmware package version on the selected controller is higher than the specified firmware package version, the command returns an error. For error codes, refer to Oracle Hardware Management Pack documentation at https://docs.oracle.com/en/servers/management.html.
- To upgrade the firmware packages and process all of the above
component upgrades, type
y
.Updating c5: Success Updating c6: Success Verifying all priority 1 updates ========================================================== ID Priority Action Status Old Firmware Ver. Proposed Ver. New Firmware Ver. System Reboot ------------------------------------------------------------------------------------------------------------------- c5 1 Check FW Success 2CV1RC30 2CV1RC50 N/A None c6 1 Check FW Success 2CV1RC30 2CV1RC50 N/A None System Reboot required for some applied firmware Do you wish to automatically reboot now? [y/n]?
- Type
y
to reboot the host server to initialize the firmware update.
-
Verify that an XML metadata file is available for the
server.
-
Re-access the console. See step 2.
For more instructions, refer to the server Installation Guide.
-
Verify that updated firmware packages are installed in Oracle 3.84 TB
NVMe SSDs.
-
Type the following from a terminal:
#
fwupdate list controller
In the following example, Oracle 3.84 TB NVMe SSDs are displayed.
#
fwupdate list controller ================================================== CONTROLLER ================================================== ID Type Manufacturer Model Product Name FW Version ----------------------------------------------------------------------------- c0 NVMe Samsung 0xa824 SAMSUNG MZWLR7T6HALA-00AU3MPK94R5Q c1 NVMe Intel 0x0b60 INTEL SSDPF2KX076T9S 2CV1RC50 c2 HDC Intel 0xa182 0x4873 - c3 NVMe Intel 0x0b60 INTEL SSDPF2KX076T9S 2CV1RC50 c4 NVMe Intel 0x0b60 INTEL SSDPF2KX076T9S 2CV1RC50 c5 NVMe Intel 0x0b60 INTEL SSDPFCKE064T9S 2CV1RC50 c6 NVMe Intel 0x0b60 INTEL SSDPFCKE064T9S 2CV1RC50 c7 NVMe Intel 0x0b60 INTEL SSDPFCKE064T9S 2CV1RC50 c8 NVMe Intel 0x0b60 INTEL SSDPFCKE064T9S 2CV1RC50 c9 NVMe Intel 0x0b60 INTEL SSDPF2KX076T9S 2CV1RC50 c10 NVMe Intel 0x0b60 INTEL SSDPF2KX076T9S 2CV1RC50 c11 NVMe Intel 0x0b60 INTEL SSDPF2KX076T9S 2CV1RC50 -
Verify host recognition of all Oracle 3.84 TB NVMe SSD and 6.4
TB NVMe SSD v2s by checking PCIe ID enumeration.
In the above example, Oracle 3.84 TB NVMe SSD controllers
c0
toc11
are enumerated in the output returned by the above command with firmware2CV1RC50
. -
Ensure that Oracle 3.84 TB NVMe SSD and 6.4 TB NVMe SSD
firmware was updated in the output returned by the above
command.
In the above example, Oracle 3.84 TB NVMe SSD controllers
c5
andc6
show firmware version2CV1RC50
.
-
Type the following from a terminal:
- Verify Oracle 3.84 TB NVMe SSD operation.
-
Repeat the firmware upgrade process until Oracle 3.84 TB NVMe SSDs
have the most up to date firmware release.
See Minimum Supported Card Firmware Version.
For example, upgrade firmware revision to 2CV1R150.
Related Information
-
For CLI command instructions, refer to Oracle Hardware Management Pack documentation at https://docs.oracle.com/en/servers/management.html.
Oracle Server CLI Tools User's Guide
Parent topic: Accessing Software Updates and Firmware Downloads
Verify Oracle 3.84 TB NVMe SSD Operation
-
Verify that Oracle Hardware Management Pack is installed on the host.
For CLI command instructions, refer to Oracle Hardware Management Pack documentation at https://docs.oracle.com/en/servers/management.html.
-
Ensure that you have access to the server (either directly or over the network).
This procedure provides instructions to verify Oracle 3.84 TB NVMe SSD operation on the host for supported Oracle Solaris and Oracle Linux operating systems. Verify Oracle 3.84 TB NVMe SSD operation using Oracle Hardware Management Pack utility CLI tools.
-
Observe Oracle 3.84 TB NVMe SSD status indicator LEDs.
Verify that the Fault-Service Action Required Oracle 3.84 TB NVMe SSD status indicator is not lit and that the green Power status indicator is lit on Oracle 3.84 TB NVMe SSDs that you updated.
Refer to LED Status Indicator Characteristics in Oracle 3.84 Tbyte, 2.5-inch, NVMe Solid State Drive Specification.
-
Log in to the target system.
For detailed instructions, refer to the server installation guide. For example, to log in to the target system through SSH or through Oracle ILOM Remote System Console Plus, do one of the following:
-
If you are using an SSH client connection.
-
From a shell command line in a terminal window, establish an SSH connection to the server host.
Type: ssh root@hostname , where hostname can be the DNS name or the IP address for the server host.
-
Log in to the system using an account with root access.
-
Proceed to Step 3.
-
-
If you are using a remote system console, refer to the server administration guide and perform these steps.
-
Establish a remote connection to the host console.
Start an Oracle ILOM serial console session, type:
-> start /HOST/console
Are you sure you want to start /HOST/console (y/n)? y
To launch an Oracle ILOM Remote System Console Plus session, refer to Launching Remote KVMS Redirection Sessions in the server administration guide.
-
Ensure that the server is powered on and booted.
-
Access the operating system command-line interface.
You issue Oracle Hardware Management Pack commands from the operating system command-line interface.
-
-
-
Identify all Oracle 3.84 TB NVMe SSDs and verify that the latest
firmware packages are installed.
-
Type the following command: #
fwupdate list controller.
#
fwupdate list controller ================================================== CONTROLLER ================================================== ID Type Manufacturer Model Product Name FW Version ----------------------------------------------------------------------------- c0 NVMe Samsung 0xa824 SAMSUNG MZWLR7T6HALA-00AU3MPK94R5Q c1 NVMe Intel 0x0b60 INTEL SSDPF2KX076T9S 2CV1RC30 c2 HDC Intel 0xa182 0x4873 - c3 NVMe Intel 0x0b60 INTEL SSDPF2KX076T9S 2CV1RC30 c4 NVMe Intel 0x0b60 INTEL SSDPF2KX076T9S 2CV1RC30 c5 NVMe Intel 0x0b60 INTEL SSDPFCKE064T9S 2CV1R104 c6 NVMe Intel 0x0b60 INTEL SSDPFCKE064T9S 2CV1R104 c7 NVMe Intel 0x0b60 INTEL SSDPFCKE064T9S 2CV1R103 c8 NVMe Intel 0x0b60 INTEL SSDPFCKE064T9S 2CV1R103 c9 NVMe Intel 0x0b60 INTEL SSDPF2KX076T9S 2CV1RC30 c10 NVMe Intel 0x0b60 INTEL SSDPF2KX076T9S 2CV1RC30 c11 NVMe Intel 0x0b60 INTEL SSDPF2KX076T9S 2CV1RC30 -
Verify host recognition of all Oracle 3.84 TB NVMe SSDs by
checking controller ID enumeration.
In the above example, Oracle 3.84 TB NVMe SSD controllers
c0
andc1
are enumerated in the output returned by the above command. - Ensure that all Oracle 3.84 TB NVMe SSD firmware revisions are current in the FW Version output returned by the above command.
-
Type the following command: #
fwupdate list controller.
-
Check NVMe device status.
To identify NVMe controllers and current firmware versions, type
#
nvmeadm list -v.To identify NVMe controllers that have updated firmware, view the
Firmware Revision
row in the output from the nvmeadm list -v command.In the following example, controllers
SUNW-NVME-1
andSUNW-NVME-1
show firmware version2CV1RC30
in the output returned by the above command.#
nvmeadm list -v SUNW-NVME-1 PCI Vendor ID: 0x144d Serial Number: S64TNE0N800033 Model Number: SAMSUNG MZWLR7T6HALA-00AU3 Firmware Revision: MPK94R5Q Number of Namespaces: 32 SUNW-NVME-2 PCI Vendor ID: 0x8086 Serial Number: PHAB011200LV7P6GGN Model Number: INTEL SSDPF2KX076T9S Firmware Revision: 2CV1RC30 Number of Namespaces: 128 SUNW-NVME-3 PCI Vendor ID: 0x8086 Serial Number: PHAB011200G17P6GGN Model Number: INTEL SSDPF2KX076T9S Firmware Revision: 2CV1RC30 Number of Namespaces: 128 -
Check Oracle 3.84 TB NVMe SSD health and SMART information.
To check the selected Oracle 3.84 TB NVMe SSD health and SMART (Self-Monitoring, Analysis, and Reporting Technology) information, type:
#
nvmeadm getlog -hEnsure that Oracle 3.84 TB NVMe SSDs have remaining drive life (
Percentage Used
) in the output returned by the above command.#
nvmeadm getlog -h SUNW-NVME-1 SMART/Health Information: Critical Warning: 0 Temperature: 315 Kelvin Available Spare: 100 percent Available Spare Threshold: 10 percent Percentage Used: 0 percent Data Unit Read: 0x2fa1c314 of 512k bytes. Data Unit Written: 0x23bd12c7 of 512k bytes. Number of Host Read Commands: 0x3f0bb9308 Number of Host Write Commands: 0x1c2433434 Controller Busy Time in Minutes: 0x525 Number of Power Cycle: 0x56e Number of Power On Hours: 0x55f Number of Unsafe Shutdown: 0x307 Number of Media Errors: 0x0 Number of Error Info Log Entries: 0x0 SUNW-NVME-2 SMART/Health Information: Critical Warning: 0 Temperature: 310 Kelvin Available Spare: 99 percent Available Spare Threshold: 10 percent Percentage Used: 1 percent Data Unit Read: 0x138a818a of 512k bytes. Data Unit Written: 0x2d71a25d of 512k bytes. Number of Host Read Commands: 0xe75e59ca Number of Host Write Commands: 0x7a604b45c Controller Busy Time in Minutes: 0xe0 Number of Power Cycle: 0x89 Number of Power On Hours: 0x1443 Number of Unsafe Shutdown: 0x78 Number of Media Errors: 0x0 Number of Error Info Log Entries: 0x0Related Information
-
Oracle Hardware Management Pack documentation at: https://docs.oracle.com/en/servers/management.html
Parent topic: Accessing Software Updates and Firmware Downloads