Configure Library Settings

Library settings include the library name, partitioning activation, initialization settings, volume label format, and HTTP listening port settings.

  1. This procedure assumes you have started the configuration wizard and selected Configure Library Settings.
  2. Enter the Library Name and Domain Name.
  3. Select the library settings, as applicable:
    • Library Partitioning Active - Selecting this option enables partitioning in the library. You no longer need a hardware activation file to enable partitioning.
    • Bypass audit if door opened with power off – Normally, if a door opens while the library is off, the library will run a full audit when it resumes operation. However, if you plan to enter the library while it is off, but will not move any tape cartridges, then you can enable this option to bypass the full audit. This is also known as "suppress HBO" (suppress Has Been Opened). Only select this option if you are not going to add, remove, or move any tapes or drive trays.
    • Probe for physical configuration changes upon next restart - The robot will scan the module identification blocks during startup and perform a full audit. You must select this option when modifying the physical configuration. The probe only occurs on the initial restart after you select this option. Then, this option resets, so that subsequent restarts will not probe for configuration changes.
    • System Cell Volume Label Format – Controls the presentation of system cell volsers. To change the label format for normal storage cells, you must change the Volume Label Format of the partition containing the cells.
    • IPv4 HTTP Listening Port - Default is 80. Valid custom values are 10000-22000. IPv6 HTTP listens only on port 7102.
    • IPv4HTTPS Listening Port - Default is 443. Valid custom values are 10000-22000. Pv6 HTTPS listens only on port 7103.