Probe for Physical Configuration Changes
After physically changing the library (such as adding a CAP, module, drive array and so on), you must tell the library to probe for the configuration changes, which has the robot scan each module identification block after the library restarts.
- Select Configure Library Settings, and then click Next.
- On the Configure Library Settings screen, select the Probe for configuration changes upon next restart option. Click Next.
- Accept the changes, and then click Apply.
- Restart the library.
Physical configuration changes include:
- Adding or removing modules, rotational CAPs, drive arrays, and so on.
- Converting a Cartridge Module into a Parking Module or vice versa.
Physical configuration changes do not include:
- Adding, removing, or moving tape cartridges or drive trays.
- Adding or removing robots or controller cards.