Overview of the Sun ZFS Storage 7320 Controller
This section provides an overview of the Sun ZFS Storage 7320 controller. For installation instructions, refer to Installing a Sun ZFS Storage 7x20 Controller. For service instructions, refer to Servicing the Sun ZFS Storage 7x20 Controller in Oracle ZFS Storage Appliance Customer Service Manual, Release OS8.8.x.
Sun ZFS Storage 7320 Electrical Specifications
The following list shows the electrical specifications for the Sun ZFS Storage 7320 controller.
Note:
The power dissipation numbers listed are the maximum rated power numbers for the power supply. The numbers are not a rating of the actual power consumption of the appliance.Connectors
-
Two C13 connectors, which work on 110-220v outlets
Input
-
Nominal frequencies: 50/60Hz
-
Nominal voltage range: 100-120/200-240 VAC
-
Maximum current AC RMS: 9.0 amps Max
-
AC operating range: 90-264 VAC
Output
-
3.3 VDC STBY: 3.6A
-
+12 VDC: 62.3A
Power dissipation
-
Max power consumption: 873 W
-
Max heat output: 2977 BTU/hr
-
Volt-Ampere rating: 891 VA @ 240 VAC, 0.98P.F.
Sun ZFS Storage 7320 Base Configurations
The Sun ZFS Storage 7320 controller base configuration options are:
-
Single or cluster
-
24GB or 96GB RAM
-
2x2.4GHz Quad-Core processors
-
One external SAS HBA
-
Four 10/100/1000 Ethernet ports
Sun ZFS Storage 7320 Front Panel Components
The following figure and legend identify the Sun ZFS Storage 7320 front panel LEDs.
![Graphic showing the components on the front panel of the controller Graphic showing the components on the front panel of the controller](img/leds7320.png)
1 Locate Button/LED |
2 Service Required LED (amber) |
3 Power/OK LED (green) |
4 Power Button |
5 Rear Power Supply |
6 System Overtemperature LED |
7 Top Fan |
The following figure and legend identify the Sun ZFS Storage 7320 front panel drive locations. Two mirrored hard disk drives (HDDs) that store the operating system reside in slots 0 and 1. Up to four solid state drives (ReadZilla SSDs), which store the read cache, fill slots 2 through 5, in order. Slots 6 and 7 are empty and must contain drive fillers.
![Graphic showing the drive locations at the front of the controller Graphic showing the drive locations at the front of the controller](img/front_panel7320.png)
Disk Drive Locations
HDD1 |
HDD3 |
HDD5 |
||
HDD0 |
HDD2 |
HDD4 |
HDD6 |
HDD7 |
Sun ZFS Storage 7320 Rear Panel Components
Following is an illustration of the Sun ZFS Storage 7320 storage controller rear panel. The Sun 375-3609 belongs in slot 2, cannot be installed in any other slots, and a second is not offered as an option.
For information about PCIe cards, see Sun ZFS Storage 7320 Configuration Options in Oracle ZFS Storage Appliance Customer Service Manual, Release OS8.8.x.
![Graphic showing the components located at the front of the controller Graphic showing the components located at the front of the controller](img/rear_panel7320.png)
1 Power supplies |
2 SC summary status LEDs |
3 Serial management port |
4 Network management (NET MGT) 10/100 BASE-T Ethernet port |
5 Ethernet ports |
6 PCIe slots |
The Sun ZFS Storage 7320 controller has the following ports:
-
Ethernet Ports - There are four RJ-45 Gigabit Ethernet ports (NET 0, NET 1, NET 2, NET 3) located on the motherboard that operate at 10/100/1000 Mbit/sec. These network interfaces must be configured before use.
-
Network Management Port - The network management connector (NET MGT) is an RJ-45 10/100 BASE-T Ethernet port and provides an alternate terminal interface to the SP console.
-
Serial Management Port - The serial management connector (SERIAL MGT) is an RJ-45 connector and is a terminal connection to the SP console.