Synchronizing Across Process Boundaries

Each of the synchronization primitives can be set up to be used across process boundaries. This cross-boundary setup is done by ensuring that the synchronization variable is located in a shared memory segment and by calling the appropriate init routine with type set to USYNC_PROCESS.

If type is set to USYNC_PROCESS, then the operations on the synchronization variables work just as the variables do when type is USYNC_THREAD.

mutex_init(&m, USYNC_PROCESS, 0);
rwlock_init(&rw, USYNC_PROCESS, 0);
cond_init(&cv, USYNC_PROCESS, 0);