B Replacement Units

This appendix lists the replacement units for the components in Oracle Big Data Appliance racks. All replacement units are field replaceable units (FRUs), which are installed by Oracle field engineers.

This appendix contains the following sections:

B.1 Understanding Repair Categories

Repair categories describe the potential effects of a repair action. Table B-1 describes the categories and related actions.

Table B-1 Oracle Big Data Appliance Repair Categories

Category Description Scenario Examples

Hot Swap (HS)

The repair part is hot swappable and can be replaced without shutting down the host system. Procedures may be needed before and after replacement to protect the data.

  • Disks

  • Fans

  • Power supplies

Infrastructure Repair (IR)

Repair of a connectivity component within an Oracle Big Data Appliance rack. No downtime of the rack is required; however, individual components may require downtime.

  • External cables

  • InfiniBand switch

  • Ethernet switch

BDA Server Offline (BDA-O)

Repair of the part requires shutting down one Big Data Appliance server. No downtime of the rack is required; however, individual servers may require downtime and temporary removal from the cluster. Rebalancing the workload and data duplication may temporarily affect performance.

If the system is currently running, then shut it down gracefully. See "Powering On and Off Oracle Big Data Appliance" for additional information.

If you monitor the system using Oracle Enterprise Manager Cloud Control, then prevent unnecessary alerts by putting the target in a blackout state. Refer to Oracle Enterprise Manager Administration for additional information.

  • System boards

  • PCIe cards

  • Memory

  • Processors


B.2 Disk Controller Batteries

The disk controllers in the servers have battery-backed write cache to accelerate write performance. If the battery charge capacity degrades such that the battery cannot protect the cached data for a power loss of 48 hours or more, then the write cache is disabled and the disk controller switches to write through mode. This results in reduced write performance but no data loss. The servers generate an alert when the battery charge is insufficient, when the temperature is high, and when the battery should be replaced.

Battery charge capacity degrades over time, and the life expectancy of a battery is inversely proportional to the operating temperature. The worst-case life expectancy of a battery in an Oracle Big Data Appliance rack is as follows:

Inlet Ambient Temperature Battery Lifetime
< 25 degrees Celsius (77 degrees Fahrenheit) 3 years
< 32 degrees Celsius (90 degrees Fahrenheit) 2 years

Oracle replaces failed batteries at no extra charge if the battery charge capacity in the disk controllers falls below the minimum threshold. As part of Oracle Premier Support for Systems, Oracle attempts to proactively replace the batteries in an Oracle Big Data Appliance rack before the end of the estimated lifetime, on a best effort basis.

B.3 LED Status Descriptions

This section describes the light-emitting diodes (LEDs) in an Oracle Big Data Appliance rack. It contains these topics:

B.3.1 Sun Server LEDs

Table B-2 identifies some LED status indicators on a Sun Server X3-2L that can indicate a fault.

See Also:

"About Server and Component LEDs" in the Sun Server X3-2L Service Manual at

http://docs.oracle.com/cd/E23393_01/html/E27229/z40003ec1405942.html

Table B-2 LED Status Descriptions

Component LED Status

General Status

The following LEDs are located on the front and back panels of each server:

Service Required (amber) 

  • Off indicates normal operation.

  • Steady on indicates a fault in the server.

Power/OK (green) 

  • Steady on indicates that the server is powered on.

  • A slow blink indicates that the server is starting up.

  • A steady blink indicates that standby power is on.

  • Off indicates no AC power.

Drives

The following LEDs are located on the storage and boot drives:

Service Required (amber) 

  • Off indicates normal operation.

  • Steady on indicates a fault in the drive.

Activity (green) 

  • Steady on indicates normal inactivity.

  • A steady blink indicates normal activity.

  • Off indicates that the power is off or the system does not recognize the drive.

Fans

Each fan module has one bicolored LED.

Fan Status (amber/green) 

  • Amber indicates that the fan module is faulty. The front and rear panel Service Required LEDs are also lit when the system detects a fan module fault.

  • Green indicates that the system is powered on and the fan module is functioning correctly.

Power supply

The following LEDs are on each power supply. You can see them from the back of the server.

Service Required (amber) 

  • Off indicates normal operation.

  • Steady on indicates that the system has detected a problem in the power supply regarding the voltage, current, temperature, or fans.

AC OK/DC OK (green) 

  • Steady on indicates normal operation for both AC and DC power.

  • A slow blink indicates that input AC power is normal and output DC power is disabled.

  • Off indicates no input AC power.

AC OK (green) 

  • Steady on indicates normal operation.

  • Off indicates no AC power.


B.3.2 Sun InfiniBand Switch LEDs

Table B-3 identifies some LED status indicators on Sun Datacenter InfiniBand Switch 36 and Sun Network QDR InfiniBand Gateway switches that can indicate a fault.

See Also:

Table B-3 Sun Datacenter InfiniBand Switch 36 LED Status Descriptions

Component LED Status

Chassis

The following LEDs are located on the left side of the rear panel.

Attention (amber) 

  • Steady on indicates a fault.

  • Off indicates normal operation.

  • Flashing indicates no function.

OK (green) 

  • Steady on indicates normal operation.

  • Off indicates that the switch is off or initializing.

  • Flashing indicates no function.

Link status

The link status LEDs are located by the data cable connectors on the rear panel.

Link (green) 

  • Steady on indicates that a link is established.

  • Off indicates that the link is down.

  • Flashing indicates that there are symbol errors.

Network management ports

The following LEDs are located on the network management connector on the rear panel.

Link Speed (amber/green): 

  • Green steady on indicates a 1000BASE-T link.

  • Amber steady on indicates a 100BASE-T link.

  • Off indicates no link.

  • Flashing indicates no function.

Activity (green): 

  • Flashing indicates packet activity.

  • On indicates no function.

  • Off indicates no activity.

Power supply

The following LEDs are located on the power supply at the front of the chassis.

Attention (amber) 

  • Steady on indicates a fault, and 12 VDC is shut down.

  • Off indicates normal operation.

  • Flashing indicates no function.

OK (green) 

  • Steady on indicates 12 VDC.

  • Off indicates no DC voltage.

  • Flashing indicates no function.

AC LED is green 

  • Steady on indicates AC power is supplied.

  • Off indicates that AC power is not present.

  • Flashing indicates no function.

Fan

The following LED is located on the air inlet on the front of the chassis.

FT 

  • On indicates a problem with the fan.

  • Off indicates normal operation


B.4 Parts for Oracle Big Data Appliance Servers

An Oracle Big Data Appliance rack contains either Sun Server X3-2L or Sun Fire X4270 M2 servers.

Note:

Oracle Big Data Appliance ships with two spare drives. If a drive is faulty, then the customer can replace the drive before an Oracle service representative arrives if circumstances warrant immediate action.

Table B-4 lists the replaceable parts for the Sun Server X3-2L, which are covered under the Oracle Premier Support for Systems warranty. Unless otherwise noted, the repair procedures are in the Sun Server X3-2L Service Manual.

Table B-4 Replacement Parts for a Sun Server X3-2L Server

Part Number Description Repair Category Repair Procedure

150-3993

Battery, 3V, 390 MAH, LITH, COIN

BDA-O

See "Servicing the Battery" at

http://docs.oracle.com/cd/E23393_01/html/E27229/z40000f91037456.html#scrolltoc

Note: Rear storage drive 1 might be populated with a remote battery module for the host bus adapter (HBA) card. See "Remove a Rear Storage Drive" at

http://docs.oracle.com/cd/E23393_01/html/E27229/bbggjgea.html#scrolltoc

7050794

4 GB USB 2.0 flash drive, RoHS:Y

BDA-O

See "Servicing the Internal USB Flash Drives" at

http://docs.oracle.com/cd/E23393_01/html/E27229/ceiicfbd.html#scrolltoc

371-4982

6 Gigabit SAS RAID PCI battery module, RoHS:Y (LION), BBU-08

BDA-O

  1. Power down the server gracefully. See "Powering Down the Server" at

    http://docs.oracle.com/cd/E23393_01/html/E27229/z400061b1011735.html

  2. See Sun Storage 6 Gb SAS PCIe HBA, Internal Installation Guide For HBA Models SGX-SAS6-INT-Z and SG-SAS6-INT-Z (internal only) at

    http://docs.oracle.com/cd/E19337-01/index.html

375-3696

InfiniBand (CX2) dual port CX2 4x QDR PCI-e

BDA-O

  1. Power down the server gracefully. See "Powering Down the Server" at

    http://docs.oracle.com/cd/E23393_01/html/E27229/z400061b1011735.html

  2. See "Servicing PCIe Cards" at

    http://docs.oracle.com/cd/E23393_01/html/E27229/z40000f91037409.html

7047503

6 Gbps SAS RAID disk PCIe HBA, RoHS:Y

BDA-O

  1. Power down the server gracefully. See "Powering Down the Server" at

    http://docs.oracle.com/cd/E23393_01/html/E27229/z400061b1011735.html

  2. See "Servicing PCIe Cards" at

    http://docs.oracle.com/cd/E23393_01/html/E27229/z40000f91037409.html

Note: Do not run any controller commands when replacing the disk.

7010036

DR 3 TB, 3.5-inch, SAS/7200, CORAL

HS

See "Servicing Storage Drives and Rear Drives" at

http://docs.oracle.com/cd/E23393_01/html/E27229/z40000091011460.html

Do not run any controller commands when replacing the disk.

Note: Rear storage drive 1 might be populated with a remote battery module for the host bus adapter (HBA) card. See "Remove a Rear Storage Drive" at

http://docs.oracle.com/cd/E23393_01/html/E27229/bbggjgea.html#scrolltoc

7014391

SAS expander assembly

BDA-O

See "Servicing the SAS Expander Module" at

http://docs.oracle.com/cd/E23393_01/html/E27229/ceieidja.html

7038720

DIMM, 8 GB, DDR3, 1600 MHz, 1.3V

BDA-O

See "Servicing the DIMMs" at

http://docs.oracle.com/cd/E23393_01/html/E27229/ceicjagi.html#scrolltoc

7018704

DIMM, 16 GB, DDR3, 1600 MHz, 1.35V

BDA-O

See "Servicing the DIMMs" at

http://docs.oracle.com/cd/E23393_01/html/E27229/ceicjagi.html#scrolltoc

7041013

DIMM, 32 GB, DDR3, RDIMM-1066, QUAD-RANK

BDA-O

See "Servicing the DIMMs" at

http://docs.oracle.com/cd/E23393_01/html/E27229/ceicjagi.html#scrolltoc

7020774

Pregreased CPU heatsink

BDA-O

See "Servicing Processors" at

http://docs.oracle.com/cd/E23393_01/html/E27229/z40001d31037480.html#scrolltoc

7026881

CPU,Intel,E5-2660,2.2 GHz, 8-core

BDA-O

See "Servicing Processors" at

http://docs.oracle.com/cd/E23393_01/html/E27229/z40001d31037480.html#scrolltoc

7044130

Power supply, AC, A258, F, 12V, 1000W

HS

See "Servicing Power Supplies" at

http://docs.oracle.com/cd/E23393_01/html/E27229/z40000091014153.html

7045042

Dual counter rotating fan module, 80x80 mm

HS

See "Servicing Fan Modules" at

http://docs.oracle.com/cd/E23393_01/html/E27229/z40000091014194.html

7047257

12-slot backplane cable kit with the following:

  • Disk drive flex cable

  • Dual backplane power cable

  • Single backplane power cable

  • Disk data cable, iPass+ HD to iPass+ HD, 600 mm

BDA-O

  1. Shut down the rack. See "Powering On and Off Oracle Big Data Appliance".

  2. See "Servicing the Front and Rear Storage Drive Backplanes" at

    http://docs.oracle.com/cd/E23393_01/html/E27229/z40007ac1419009.html

7047768

12-slot 3.5” disk cage, including fan door, and left and right ear assembly

BDA-O

  1. Shut down the rack. See "Powering On and Off Oracle Big Data Appliance".

  2. See "Servicing the Front and Rear Storage Drive Backplanes" at

    http://docs.oracle.com/cd/E23393_01/html/E27229/z40007ac1419009.html

7049382

System board assembly, RoHS:Y

BDA-O

  1. Shut down the rack. See "Powering On and Off Oracle Big Data Appliance".

  2. "Servicing the Motherboard Assembly" at

    http://docs.oracle.com/cd/E23393_01/html/E27229/z40001d31037512.html


Table B-5 lists the replaceable parts for the Sun Fire X4270 M2, which are covered under the Oracle Premier Support for Systems warranty. Unless otherwise noted, the repair procedures are in the Sun Fire X4270 M2 Server Service Manual.

Table B-5 Replacement Parts for Sun Fire X4270 M2 Servers

Part Number Description Repair Category Repair Procedure

150-3993

Battery, 3V, 390 MAH, LITH, COIN

BDA-O

See Section 4.6, "Servicing the Server Battery" in Sun Fire X4270 M2 Server Service Manual at

http://docs.oracle.com/cd/E19245-01/821-0488-12/motherboard.html#50438179_71528

300-2235

Power supply, A249, 1200W, 12V, 2U, RoHS:Y

HS

See Section 3.4, "Servicing Power Supplies" in Sun Fire X4270 M2 Server Service Manual at

http://docs.oracle.com/cd/E19245-01/821-0488-12/hotswap.html#50438178_11706

350-1502

Universal rack mount kit

BDA-O

  1. If the system is currently running, then shut it down gracefully. See "Powering On and Off Oracle Big Data Appliance."

  2. See Chapter 2, "Installing the Server Into a Rack With Slide-Rails" in Sun Fire X4170 M2 and X4270 M2 Servers Installation Guide at

    http://docs.oracle.com/cd/E19245-01/E27205/z4000c671007752.html

371-4743

4 GB USB 2.0 flash drive, RoHS:Y

BDA-O

Not applicable

371-4966

LV DIMM, 8 GB, DDR3, 1RX4, 1333 MHz

BDA-O

See Section 4.2, "Servicing Memory Modules (DIMMs)" in Sun Fire X4270 M2 Server Service Manual at

http://docs.oracle.com/cd/E19245-01/821-0488-12/motherboard.html#50438179_71526

371-4982

6 Gigabit SAS RAID PCI battery module, RoHS:Y (LION), BBU-08

BDA-O

  1. If the system is currently running, then shut it down gracefully. See "Powering On and Off Oracle Big Data Appliance."

  2. See Sun Storage 6 Gb SAS PCIe HBA, Internal Installation Guide For HBA Models SGX-SAS6-INT-Z and SG-SAS6-INT-Z (internal only) at

    http://docs.oracle.com/cd/E19337-01/index.html

375-3696

InfiniBand (CX2) dual port CX2 4x QDR PCI-e

BDA-O

  1. If the system is currently running, then shut it down gracefully. See "Powering On and Off Oracle Big Data Appliance."

  2. See Section 4.5, "Servicing PCIe Cards" in Sun Fire X4270 M2 Server Service Manual at

    http://docs.oracle.com/cd/E19245-01/821-0488-12/motherboard.html#50438179_86021

375-3701

6 Gbps SAS RAID disk PCIe HBA, RoHS:Y

BDA-O

  1. If the system is currently running, then shut it down gracefully. See "Powering On and Off Oracle Big Data Appliance."

  2. See Section 4.5, "Servicing PCIe Cards" in Sun Fire X4270 M2 Server Service Manual at

    http://docs.oracle.com/cd/E19245-01/821-0488-12/motherboard.html#50438179_86021

Note: Do not run any controller commands in the service manual when replacing the disk.

530-3927

Cable, PDB, MB, 1U+2U, ribbon

BDA-O

See Section 5.10, "Servicing Cables " in Sun Fire X4270 M2 Server Service Manual at

http://docs.oracle.com/cd/E19245-01/821-0488-12/infrastructure_x4270_M2.html#50438167_58217

530-4228

Cable, mini-SAS, 36 POS LONG, LY, RoHS:Y

BDA-O

See Section 5.10, "Servicing Cables" in Sun Fire X4270 M2 Server Service Manual at

http://docs.oracle.com/cd/E19245-01/821-0488-12/infrastructure_x4270_M2.html#50438167_78806

541-2075

Bus_bar, power, 1U+2U, RoHS:Y

BDA-O

See Section 5.6, "Servicing the Power Distribution Board" in Sun Fire X4270 M2 Server Service Manual at

http://docs.oracle.com/cd/E19245-01/821-0488-12/infrastructure_x4270_M2.html#50438167_85936

541-2884

Assembly, riser, X8, X8, 2U, PCI-E, RoHS:Y

BDA-O

See Section 4.4, "Servicing PCIe Risers" in Sun Fire X4270 M2 Server Service Manual at

http://docs.oracle.com/cd/E19245-01/821-0488-12/motherboard.html#50438179_53252

541-3310

Xeon Heatsink with grease, RoHS:Y, 2U

BDA-O

See Section 4.7, "Servicing CPUs" in Sun Fire X4270 M2 Server Service Manual at

http://docs.oracle.com/cd/E19245-01/821-0488-12/motherboard.html#50438179_23425

541-3356

x8/x8 switched PCIe riser assembly, RoHS:Y with the following:

  • x8/x8 switch PCIe riser

  • bracket

BDA-O

  1. If the system is currently running, then shut it down gracefully. See "Powering On and Off Oracle Big Data Appliance."

  2. See Section 4.4, "Servicing PCIe Risers" in Sun Fire X4270 M2 Server Service Manual at

    http://docs.oracle.com/cd/E19245-01/821-0488-12/motherboard.html#50438179_53252

541-4081

System board assembly, RoHS:Y

BDA-O

  1. If the system is currently running, then shut it down gracefully. See "Powering On and Off Oracle Big Data Appliance."

  2. See Section 4.8, "Servicing the Motherboard" in Sun Fire X4270 M2 Server Service Manual at

    http://docs.oracle.com/cd/E19245-01/821-0488-12/motherboard.html#50438179_98526

541-4124

Fan deck, Hyde, RoHS:Y

BDA-O

See Section 5.3, "Servicing the Fan Board" in Sun Fire X4270 M2 Server Service Manual at

http://docs.oracle.com/cd/E19245-01/821-0488-12/infrastructure_x4270_M2.html#50438167_71556

541-4222

Assembly, fan, CR, 2U, RoHS:Y

HS

See Section 3.3, "Servicing Fan Modules" in Sun Fire X4270 M2 Server Service Manual at

http://docs.oracle.com/cd/E19245-01/821-0488-12/hotswap.html#50438178_28930

541-4223

Power distribution board, 2U, RoHS:Y

BDA-O

See Section 5.6, "Servicing the Power Distribution Board" in Sun Fire X4270 M2 Server Service Manual at

http://docs.oracle.com/cd/E19245-01/821-0488-12/infrastructure_x4270_M2.html#50438167_71558

541-4304

Indicator, right, Hyde 12/24, RoHS:Y

BDA-O

See Section 5.5, "Servicing the Front Panel LED Modules" in Sun Fire X4270 M2 Server Service Manual at

http://docs.oracle.com/cd/E19245-01/821-0488-12/infrastructure_x4270_M2.html#50438167_71563

541-4305

Assembly, disk, SAS2, XP_DC, Hyde, RoHS:Y

BDA-O

See Section 5.2, "Servicing the SAS Expander Board" in Sun Fire X4270 M2 Server Service Manual at

http://docs.oracle.com/cd/E19245-01/821-0488-12/infrastructure_x4270_M2.html#50438167_28246

541-4306

Assembly, connector board bracket, Hyde

BDA-O

See Section 5.7, "Servicing the Connector Board" in Sun Fire X4270 M2 Server Service Manual at

http://docs.oracle.com/cd/E19245-01/821-0488-12/infrastructure_x4270_M2.html#50438167_pgfId-1296581

541-4363

12-slot disk backplane, RoHS:Y

BDA-O

See Section 5.4, "Servicing the Disk Backplane" in Sun Fire X4270 M2 Server Service Manual at

http://docs.oracle.com/cd/E19245-01/821-0488-12/infrastructure_x4270_M2.html#50438167_71557

541-4371

Indicator, left, Hyde 12/24, RoHS:Y

BDA-O

See Section 5.5, "Servicing the Front Panel LED Modules" in Sun Fire X4270 M2 Server Service Manual at

http://docs.oracle.com/cd/E19245-01/821-0488-12/infrastructure_x4270_M2.html#50438167_71563

560-2952

Cable kit, Hyde, RoHS:Y with the following:

  • Disk backplane power cable

  • 24-slot DBP power cable

  • 12/24 slot disk backplane signal cable

  • Fan signal cable

  • Fan power cable

BDA-O

Refer to the entries for the individual items in the kit.

7010036

FRU DR 3 TB 3.5-inch SAS/7200, CORAL

--

See Section 3.2, "Servicing Storage Drives and Boot Drives" in Sun Fire X4270 M2 Server Service Manual at

http://docs.oracle.com/cd/E19245-01/821-0488-12/hotswap.html#50438178_61628

Note: Do not run any controller commands in the service manual when replacing the disk.

7012433

3.06 GHz processor

BDA-O

See Section 4.7, "Servicing CPUs" in Sun Fire X4270 M2 Server Service Manual at

http://docs.oracle.com/cd/E19245-01/821-0488-12/motherboard.html#50438179_23425


B.5 Parts for Sun Datacenter InfiniBand Switch 36

Table B-6 lists the replaceable parts for the Sun Datacenter InfiniBand Switch 36, which are covered under the Oracle Premier Support for Systems warranty. Unless otherwise noted, the repair procedures reference the Sun Datacenter InfiniBand Switch 36 Service Manual at

http://docs.oracle.com/cd/E26698_01/index.html

See "Cables and Cable Accessories for an Oracle Big Data Appliance Rack" for information about InfiniBand cables.

Table B-6 Replacement Parts for the Sun Datacenter InfiniBand Switch 36

Part Number Description Repair Category Repair Procedure

300-2299

A247A 760 watt power supply, RoHS:Y

HS

See "Servicing Power Supplies" at

http://docs.oracle.com/cd/E26698_01/html/E26434/z40001f49112.html

350-1312

Fan module for Sun Datacenter InfiniBand Switch 36, RoHS:Y

HS

See "Servicing Fans" at

http://docs.oracle.com/cd/E26698_01/html/E26434/z40001f59112.html

371-2210

CR2032 3V battery, RoHS:Y

IR

See "Servicing the Battery" at

http://docs.oracle.com/cd/E26698_01/html/E26434/z40001f79112.html

541-3495

Sun Datacenter InfiniBand Switch 36, RoHS:YL

IR

  1. See "Replacing a Failed InfiniBand Switch".

  2. See "Installing the Switch" in the Sun Datacenter InfiniBand Switch 36 Installation Guide at

    http://docs.oracle.com/cd/E26698_01/html/E26434/cggfbhhf.html

594-6603

10 Gbps QSFP short wavelength transceiver

IR

See "Servicing Data Cables" at

http://docs.oracle.com/cd/E26698_01/html/E26434/z40001f69112.html


B.6 Parts for Sun Network QDR InfiniBand Gateway Switches

Table B-7 lists the replaceable parts for the Sun Network QDR InfiniBand Gateway switch, which are covered under the Oracle Premier Support for Systems warranty. Unless otherwise noted, the repair procedures refer to the Sun Network QDR InfiniBand Gateway Switch Service Manual at

http://docs.oracle.com/cd/E26699_01/index.html

See "Cables and Cable Accessories for an Oracle Big Data Appliance Rack" for information about InfiniBand cables.

Table B-7 Replacement Parts for the Sun Network QDR InfiniBand Gateway Switch

Part Number Description Repair Category Repair Procedure

300-2299

760 watt power supply, RoHS:Y

HS

See "Servicing Power Supplies" at

http://docs.oracle.com/cd/E26699_01/html/E26706/z40001f49112.html

350-1312

Fan module, RoHS:Y

HS

See "Servicing Fans" at

http://docs.oracle.com/cd/E26699_01/html/E26706/z40001f59112.html

371-2210

CR2032 3V battery, RoHS:Y

IR

See "Servicing the Battery" at

http://docs.oracle.com/cd/E26699_01/html/E26706/z40001f79112.html

594-6603

10 Gbps QSFP short wavelength transceiver

IR

See "Servicing Data Cables" at

http://docs.oracle.com/cd/E26699_01/html/E26706/z40001f69112.html

7014378

Assembly, system, NM2-Gateway

IR

  1. See "Replacing a Failed InfiniBand Switch".

  2. See "Installing the Gateway" in the Sun Network QDR InfiniBand Gateway Switch Installation Guide at

    http://docs.oracle.com/cd/E26699_01/html/E26706/cggfbhhf.html


B.7 Parts for the Cisco Ethernet Switch

Table B-8 lists replaceable parts for the Cisco Ethernet switch, which are covered under the Oracle Premier Support for Systems warranty.

See Also:

Cisco Catalyst 4948E and Catalyst 4948E-F Switch Installation Guide at

http://www.cisco.com/en/US/docs/switches/lan/catalyst4900/4948E/installation/guide/4948E_ins.html

Table B-8 Replacement Parts for Cisco Catalyst Ethernet Switch

Part Number Description Repair Category Repair

7055121

Cooling fan tray

HS

See Chapter 4 of the Cisco Catalyst 4948E and Catalyst 4948E-F Switch Installation Guide.

7055122

Power supply, redundant

HS

See Chapter 4 of the Cisco Catalyst 4948E and Catalyst 4948E-F Switch Installation Guide.

7055123

SNET, WS-C4948E-F

IR

See Chapter 3 of the Cisco Catalyst 4948E and Catalyst 4948E-F Switch Installation Guide.


B.8 Parts for Power Distribution Units

Table B-9 lists the replacement parts for the power distribution units (PDUs), which are covered under the Oracle Premier Support for Systems warranty. The repair procedures references the Sun Rack II Power Distribution Units User's Guide at

http://docs.oracle.com/cd/E19844-01/E23443-01/index.html

Because of the number of cables and connections, Oracle recommends shutting down the Oracle Big Data Appliance rack during the replacement of power distribution unit parts.

Table B-9 Replacement Parts for Power Distribution Units

Part Number Description Repair Category Repair Procedures

180-2379

13A/250V 90 degree IEC 320 Sheet E to IEC 320 C13 cord, 1 meter, RoHS:Y

HS

Not applicable

180-2380

13A/250V 90 degree IEC 320 Sheet E to IEC 320 C13 cord, 2 meter, RoHS:Y

HS

Not applicable

7052156

Three-phase PDU: 15 kVA, IEC309 60A, 4-pin, 250 VAC, three-phase IP67, North America, RoHS:Y

IR

See "Removing and Replacing PDUs" at

http://docs.oracle.com/cd/E19844-01/E23443-01/z40000121011643.html

7052158

Three-phase PDU: 15 kVA, 5-pin, IEC309 32A, 5-pin 230/400V, three-phase IP44, international, RoHS:Y

IR

See "Removing and Replacing PDUs" at

http://docs.oracle.com/cd/E19844-01/E23443-01/z40000121011643.html

7052153

Single-phase PDU: 15 kVA, with three 30A/250V 2-pole/3-wire NEMA L6-30P plugs, North America, RoHS:Y

IR

See "Removing and Replacing PDUs" at

http://docs.oracle.com/cd/E19844-01/E23443-01/z40000121011643.html

7052155

Single-phase PDU: 22 kVA, with three blue 32A/240V splash-proof 2-pole/3-wire IEC 60309 plugs, international, RoHS:Y

IR

See "Removing and Replacing PDUs" at

http://docs.oracle.com/cd/E19844-01/E23443-01/z40000121011643.html


B.9 Cables and Cable Accessories for an Oracle Big Data Appliance Rack

Table B-10 lists the replacement cables and cable accessories for an Oracle Big Data Appliance rack, which are covered under the Oracle Premier Support for Systems warranty.

See Also:

Table B-10 Replacement Cables for an Oracle Big Data Appliance Rack

Part Number Description Repair Category Repair

350-1287

Slim rail, CMA, 1U-2U for Sun servers

BDA-O

  1. Power down the server gracefully. See "Powering Down the Server" at

    http://docs.oracle.com/cd/E23393_01/html/E27229/z400061b1011735.html

  2. See "Install Cable Management Arm" in the Sun Server X3-2L Installation Guide at

    http://docs.oracle.com/cd/E23393_01/html/E27229/z40000401014951.html

350-1519

Serial cable kit, RoHS:Y with the following:

  • USB to DB 9-pin M serial cable

  • DB 9-pin F to DB 9-pin F null modem cable

HS

See "Understanding Cabling" in the Sun Datacenter InfiniBand Switch 36 Installation Guide at

http://docs.oracle.com/cd/E26698_01/html/E26434/cggfhjcc.html

530-4403

4x QSFP copper QDR InfiniBand cable, 2 m, RoHS:Y

HS

  1. See "Maintaining the InfiniBand Network".

  2. See "Understanding Cabling" in the Sun Datacenter InfiniBand Switch 36 Installation Guide at

    http://docs.oracle.com/cd/E26698_01/html/E26434/cggfhjcc.html

Note: Redundancy is lost during cable replacement.

530-4404

4x QSFP copper QDR InfiniBand cable, 3 m, RoHS:Y

HS

  1. See "Maintaining the InfiniBand Network".

  2. See "Understanding Cabling" in the Sun Datacenter InfiniBand Switch 36 Installation Guide at

    http://docs.oracle.com/cd/E26698_01/html/E26434/cggfhjcc.html

530-4415

4x QSFP copper QDR InfiniBand cable, 5 m, RoHS:Y

HS

  1. See "Maintaining the InfiniBand Network".

  2. See "Understanding Cabling" in the Sun Datacenter InfiniBand Switch 36 Installation Guide at

    http://docs.oracle.com/cd/E26698_01/html/E26434/cggfhjcc.html

530-4432

Ethernet cable, Cat 5/5E, RJ45 to RJ45, 7 foot, blue, RoHS:Y

HS

See Cisco Catalyst 4948E and Catalyst 4948E-F Switch Installation Guide.

530-4433

Ethernet cable, Cat 5/5E, RJ45 to RJ45, 10 foot, red, RoHS:Y

HS

See Cisco Catalyst 4948E and Catalyst 4948E-F Switch Installation Guide.

530-4434

Ethernet cable, Cat 5/5E, RJ45 to RJ45, 7 foot, red, RoHS:Y

HS

See Cisco Catalyst 4948E and Catalyst 4948E-F Switch Installation Guide.

530-4435

Ethernet cable, Cat 5/5E, RJ45 to RJ45, 10 foot, black, RoHS:Y

HS

See Cisco Catalyst 4948E and Catalyst 4948E-F Switch Installation Guide.

530-4436

Ethernet cable, Cat 5/5E, RJ45 to RJ45, 7 foot, black, RoHS:Y

HS

See Cisco Catalyst 4948E and Catalyst 4948E-F Switch Installation Guide.