Go to main content
Oracle® 1.6 TB NVMe SSD User Guide

Exit Print View

Updated: April 2016
 
 

Product Specification

Oracle 1.6 TB NVMe SSD general specifications are shown in the following table:

Specification
Value
Capacity
Usable capacity 1.6 TB
Unformatted capacity (total user addressable sectors in LBA mode) 3,125,627,568
PCIe
PCIe Gen3 x4
Form factors
  • 2.5-inch SFF (small form factor)

  • SFF-8639 compatible connector

  • 15mm Z-height

Performance

Performance values vary by capacity and form factor.

Performance specifications apply to both compressible and incompressible data.

Sequential Read/Write: Up to 2500/1500 MB/sec
Sequential Latency (typical) Read/Write: 20/20 μsec
Random Latency (typical) Read/Write: 120/30 μsec
Power On to Ready Latency (typical): 2 sec
IOPS
  • Random Read/Write 4KB 70/30: Up to 160,000

  • Random Read/Write 8KB 70/30: Up to 75,000

  • Random 4K Read: Up to 440,000

  • Random 4K Write: Up to 70,000

  • Random 8K Read: Up to 260,000

  • Random 8K Write: Up to 42,000

  • Random Read/Write Consistency 4K/8K: 90%

Components
  • High Endurance Intel® 20nm eMLC NAND Flash Memory

  • Intel® Flash Memory NVMe Controller ASIC

Reliability
  • Uncorrectable Bit Error Rate (UBER): 1 sector per 1017 bits read

  • Mean Time Between Failure (MTBF): 2 million hours

  • T10 DIF protection

Power
  • 3.3V and 12V supply rail

    3.3Vaux for SMBUS

  • Active/Idle (typical): Up to 25W/4W (typical)

  • Enhanced power-loss data protection.

Certifications and declarations
UL, CE, C-Tick, BSMI, KCC, Microsoft WHQL, VCCI
Compliance
  • NVM Express 1.0c

  • PCI Express Base Specification Rev 3.0

  • Enterprise SSD Form Factor Version 1.0a

  • PCI Express Card Electro-Mechanical (CEM) Specification Rev 2.0

Endurance rating
  • Up to 14 PBW (petabytes written)

  • 5 Drive Writes/day (JESD219 workload)

Altitude (simulated)
  • Operating: -1,000 to 10,000 ft

  • Non-Operating: -1,000 to 40,000 ft

Temperature
  • Operating:

    • 0 to 35° C ambient, 0 to 70° C case with specified airflow

    • Temperature monitoring (In-band and by way of SMBUS)

    • Thermal throttling

  • Non-Operating: -55 to 95° C

Airflow
More than 450 LFM (linear feet/minute, at 25/35° C, airflow towards the connector)
Weight
Up to 125 gm
Shock
1,000 G/0.5 msec
Vibration
  • Operating: 2.17 GRMS (5-700Hz)

  • Non-Operating: 3.13 GRMS (5-800Hz)

Product ecological compliance
RoHS

Related Information