Environmental Specifications

The Oracle 1.6 TB NVMe SSD operates and is stored in an environment defined by the parameters and specifications in the following table:

Specification
Value
Operating temperature
  • 0 to 35° C ambient, 0 to 70° C case with specified airflow

  • Operational environment: 5° C to 35° C (dry bulb)

Non-operating temperature
Storage and transit environment: –55° C to 95° C (dry bulb)
Temperature monitoring
Dry bulb temperature
Maximum dry bulb temperature shall be derated by 3.3° C per 1000 m above 500 m
Altitude (Simulated)
  • Operating: -1,000 to 10,000 ft

  • Non-Operating: -1,000 to 40,000 ft

Relative humidity range
  • Operational environment: 8% to 80% noncondensing

  • Storage and transit environment: 5% to 95% noncondensing

  • Non-operating: -20° C to 75° C noncondensing

Thermal sensors
  • Thermal sensors on the storage drives monitor flash memory modules

  • Thermal sensor temperature cannot exceed 73° C

  • See illustration in Troubleshooting NVMe Drive Cooling for thermal sensor locations.

Airflow requirement
  • More than 450 LFM (linear feet/minute, at 25/35° C, airflow towards the connector)


Note -  For specific site planning guidelines and best practices, refer to the server documentation and product notes for your server. Refer to the system site planning guide, if available.