This appendix lists the replacement units for Recovery Appliance. It contains the following topics:
All replaceable parts are field replaceable units (FRUs) under the Oracle Premier Support for Systems warranty. Oracle field engineers install the replacement parts.
Repair categories describe the potential impact of a repair action. Table B-1 describes the categories and actions.
Table B-1 Recovery Appliance Repair Categories
Category | Description | Examples |
---|---|---|
Hot Swap (HS) |
Repair part is hot swappable, and can be replaced without shutting down the host system. Commands might be required before and after replacement to protect data. |
|
Infrastructure Repair (IR) |
Repairing a connectivity component within the Recovery Appliance rack. No downtime of the rack is required; however, individual components may require downtime. |
|
Compute Server Offline (DBO) |
Repairing the part requires shutting down a compute server. No downtime of the rack is required; however, individual servers might require downtime, and they might be taken outside of the cluster temporarily. If the server is currently running, then you must shut it down. See "Powering Down the Servers". If you monitor the system using Oracle Enterprise Manager Grid Control, then avoid unnecessary alerts by putting the target in a blackout state. Refer to Oracle Enterprise Manager Administration for additional information. |
|
Storage server Offline (EBO) |
Repairing the part requires shutting down a storage server within the rack. No downtime of the rack is required; however, individual servers might require downtime, and they might be taken outside of the cluster temporarily. There also might be a temporary performance impact, while the system rebalances to maintain data redundancy. If the server is currently running, then you must shut it down. See "Powering Down the Servers". If you monitor the system using Oracle Enterprise Manager Grid Control, then avoid unnecessary alerts by putting the target in a blackout state. Refer to Oracle Enterprise Manager Administration for additional information. |
|
Table B-2 identifies the LED status indicators that can indicate faults on the compute servers and the storage servers.
Table B-2 Oracle Server LED Status Descriptions
See Also:
"About Server and Component Status Indicators" in the Sun Server X4-2 Service Manual at
http://docs.oracle.com/cd/E36975_01/html/E38045/z4000be71405942.html#scrolltoc
"About Server and Component Status Indicators" in the Sun Server X4-2L Service Manual at
http://docs.oracle.com/cd/E36974_01/html/E38145/z40003ec1405942.html#scrolltoc
Table B-3 identifies the LED status indicators that can indicate faults on Sun Datacenter InfiniBand Switch 36.
Table B-3 Sun InfiniBand Switch LED Status Descriptions
See Also:
"Identifying LEDs" in the Sun Datacenter InfiniBand Switch 36 Service Manual at
http://docs.oracle.com/cd/E26698_01/html/E26434/z40000fe1394411.html
The following topics identify the replacement parts for the Recovery Appliance compute servers:
Figure B-1 shows the front view of the Oracle Server X6-2 or X5-2.
Figure B-1 Front View of Oracle Server X6-2 or X5-2
Figure B-2 shows the rear view of the Oracle Server X6-2 or X5-2.
Figure B-2 Rear View of Oracle Server X6-2 or X5-2
Table B-4 lists the replaceable parts for Oracle Server X6-2 compute servers. Unless otherwise noted, the repair procedures are in Oracle Server X6-2 Service Manual.
Note:
All replacement parts listed in the following table are FRUs when covered under the Premier Support of Systems warranty.
Table B-4 Replacement Parts for Oracle Server X6-2 Compute Servers
Part Number | Description | Repair Category | Repair Procedure |
---|---|---|---|
350-1719 |
Assembly, slim rail, 1U - 2U, snap in |
DBO |
|
370-5621 |
3 volt lithium battery |
DBO |
See "Servicing the Battery (CRU)" at
|
542-0287 |
Drive, 600 GB 10K, SAS2, SFF |
DBO |
See "Servicing Storage Drives (CRU)" at
|
7014226 |
Cable, interlock, 125 mm |
DBO |
See "Servicing the Power, FIM, Disk Backplane Data, and DVD Cables" at |
7046442 |
Assembly, dual port, QDR CX3, host channel adapter |
DBO |
|
7051223 |
Assembly, Dual 10 GbE SFP+LP, X8 PCIe 2.0, RoHS:Y |
DBO |
See Sun Dual 10GbE SFP+ PCIe 2.0 Low Profile Adapter User's Guide at
See "Servicing PCIe Cards (CRU)" at
|
7067728 |
Heat sink, CPU 1U |
DBO |
See "Servicing Processors (FRU)" at
|
7077680 |
Assembly, riser, 2S, 1U |
DBO |
See "Servicing PCIe Risers (CRU)" at
|
7078072 |
DIMM, 32 GB, RDIMM, DDR4, 2400 |
DBO |
See "Servicing the DIMMs (CRU)" at
|
7079395 |
Power supply, AC, A256, F, 12V, 600W |
HS |
|
7081071 |
Assembly, riser, single stack, 1U |
DBO |
See "Servicing PCIe Risers (CRU)" at
|
7085209 |
HBA, 12 Gb SAS PCIe 8-port RAID internal with flash module |
DBO |
See "Servicing the Internal HBA Card (FRU)" at |
7086345 |
Assembly, super cap, 13.5 volt, 6.4F, SAS3 HBA |
DBO |
See "Servicing the Internal HBA Card (FRU)" at |
7086346 |
Cable, super cap, 620M, 6-pin, straight, SAS3 HBA |
DBO |
See "Servicing the Internal HBA SAS Cable assembly" at
|
7089073 |
Fan module |
HS |
See "Servicing Fan Modules (CRU)" at
|
7095106 |
CPU, E5-2699 v4, 2.2 GHz, 145W, 22 core, C-1 (SR1XD) |
DBO |
See "Servicing Processors (FRU)" at
|
7097205 |
Assembly, 8DBP, 1U/2U |
DBO |
See "Servicing the Disk Backplane (FRU)" at
|
7098505 |
Assembly, motherboard, 1U |
DBO |
|
Table B-5 lists the replaceable parts for Oracle Server X5-2 compute servers. Unless otherwise noted, the repair procedures are in Oracle Server X5-2 Service Manual.
Note:
All replacement parts listed in the following table are FRUs when covered under the Premier Support of Systems warranty.
Table B-5 Replacement Parts for Oracle Server X5-2 Compute Servers
Part Number | Description | Repair Category | Repair Procedure |
---|---|---|---|
350-1719 |
Assembly, slim rail, 1U - 2U, snap in |
DBO |
|
370-5621 |
3 volt lithium battery |
DBO |
See "Servicing the Battery" at
|
542-0287 |
Drive, 600 GB 10K, SAS2, SFF |
DBO |
See "Servicing Storage Drives (CRU)" at
|
7014226 |
Cable, interlock, 125 mm |
DBO |
See "Servicing the Power, FIM, Disk Backplane Data, and DVD Cables" at |
7046442 |
Assembly, dual port, QDR CX3, host channel adapter |
DBO |
|
7051223 |
Assembly, Dual 10 GbE SFP+LP, X8 PCIe 2.0, RoHS:Y |
DBO |
See Sun Dual 10GbE SFP+ PCIe 2.0 Low Profile Adapter User's Guide at
See "Servicing PCIe Cards (CRU)" at
|
7067728 |
Heat sink, CPU 1U |
DBO |
See "Servicing Processors (FRU)" at
|
7077680 |
Assembly, riser, 2S, 1U |
DBO |
See "Servicing PCIe Risers (CRU)" at
|
7078072 |
DIMM, 32 GB, LRDIMM, DDR4, 2133 |
DBO |
See "Servicing the DIMMs (CRU)" at
|
7079395 |
Power supply, AC, A256, F, 12V, 600W |
HS |
|
7081071 |
Assembly, riser, single stack, 1U |
DBO |
See "Servicing PCIe Risers (CRU)" at
|
7085209 |
HBA, 12 Gb SAS PCIe 8-port RAID internal with flash module |
DBO |
See "Servicing the Internal HBA Card (FRU)" at |
7086345 |
Assembly, super cap, 13.5 volt, 6.4F, SAS3 HBA |
DBO |
See "Servicing the Internal HBA Card (FRU)" at |
7086346 |
Cable, super cap, 620M, 6-pin, straight, SAS3 HBA |
DBO |
See "Servicing the Internal HBA SAS Cable assembly" at
|
7089073 |
Fan module |
HS |
See "Servicing Fan Modules (CRU)" at
|
7095106 |
CPU, E5-2699 v3, 2.3 GHz, 145W, 18 core, C-1 (SR1XD) |
DBO |
See "Servicing Processors (FRU)" at
|
7097205 |
Assembly, 8DBP, 1U/2U |
DBO |
See "Servicing the Disk Backplane (FRU)" at
|
7098505 |
Assembly, motherboard, 1U |
DBO |
|
Figure B-3 shows the front view of the Sun Server X4-2.
Figure B-4 shows the rear view of the Sun Server X4-2.
Table B-6 lists the replaceable parts for Sun Server X4-2 compute servers. Unless otherwise noted, the repair procedures are in Sun Server X4-2 Service Manual.
Note:
All replacement parts listed in the following table are FRUs when covered under the Premier Support of Systems warranty.
Table B-6 Replacement Parts for Sun Server X4-2 Compute Servers
Part Number | Description | Repair Category | Repair Procedure |
---|---|---|---|
7013526 |
Fan module |
HS |
See "Servicing Fan Modules" in Sun Server X4-2 Service Manual at
|
7018701 |
DIMM, 16 GB, DDR3, 2RX4, 1600, 1.35 V |
DBO |
See "Servicing the DIMMs" at
|
7020774 |
Heat sink, CPU 1U, 60 mm FIN |
DBO |
See "Servicing Storage Drives (CRU)" at
|
7023303 |
Dual 16 Gigabit/Sec Fiber Channel / 10 GbS FCoE Host Adapter, QLogic |
See "Install a PCIe Card in PCIe Slot 1 or 2" at
|
|
7027478 |
Disk Backplane, RoHS:Y |
DBO |
See "Servicing the Disk Backplane (FRU)" at
|
7039841 |
Front indicator module |
DBO |
See "Servicing PCIe Risers" at
|
7046442 |
Assembly, dual port, QDR CX3, host channel adapter |
DBO |
|
7047503 |
Assembly, 6 GB, SAS RAID disk PCIe HBA, RoHS:Y |
DBO |
See "Servicing Storage Drives" at
|
7048707 |
Assembly, riser, double stack |
DBO |
See "Servicing PCIe Risers" at
|
7048710 |
1-slot PCI Express riser assembly |
DBO |
See "Servicing PCIe Risers" at
|
7051223 |
Assembly, Dual 10 GbE SFP+LP, X8 PCIe 2.0, RoHS:Y |
DBO |
See Sun Dual 10GbE SFP+ PCIe 2.0 Low Profile Adapter User's Guide at |
7057184 |
Assembly, battery carrier remote |
HS |
|
7058153 |
Assembly, motherboard, X4-2 |
DBO |
|
7060020 |
Universal upgrade remote battery kit |
EBO |
|
7060951 |
Power supply, AC, A256, F, 12V, 600W |
HS |
|
7069232 |
CPU, E5-2697 v2, 12-core, 2.7 GHz |
DBO |
See "Servicing Processors" at
|
See Also:
Sun Server X4-2 Service Animations at
The following topics identify the replacement parts for the Recovery Appliance storage servers:
Figure B-5 shows the front view of the Oracle Server X6-2L or X5-2L. The hard drives are numbered from left to right, starting in the lower left. The drives in the bottom row are numbers 0, 1, 2, and 3. The drives in the middle row are numbers 4, 5, 6, and 7. The drives in the top row are numbers 8, 9, 10, and 11.
Figure B-5 Front View of Oracle Server X6-2L or X5-2L
Figure B-6 shows the rear view of an Oracle Server X6-2L or X5-2L storage server.
Figure B-6 Rear View of Oracle Server X6-2L or X5-2L
Table B-7 lists the replaceable parts for the Oracle Server X6-2L. Unless otherwise noted, the repair procedures are in Oracle Server X6-2L Service Manual.
Note:
All replacement parts listed in the following table are FRUs when covered under Premier Support of Systems warranty.
Table B-7 Replacement Parts for Oracle Server X6-2L Storage Servers
Part Number | Description | Repair Category | Repair Procedure |
---|---|---|---|
350-1719 |
Assembly, 1U-2U Snap-in, slim rail rack |
EBO |
|
370-5621 |
3 volt lithium battery |
EBO |
See "Servicing the Battery (CRU)" at
|
7014226 |
Cable, interlock, 125 mm |
EBO |
See "Servicing SAS Cables (FRU)" at
|
7017231 |
Indicator assembly, right |
EBO |
See "Servicing the Front LED/USB Indicator Modules (FRU)" at
|
7023515 |
Disk backplane assembly, 2 rear |
EBO |
See "Servicing the Front and Rear Storage Drive Backplanes (FRU)" at
|
7044130 |
Power Supply, A258, 1000W, AC Input |
HS |
|
7045042 |
Fan assembly, 2U, 80 x 80, Ferrite, center rotate |
HS |
See "Servicing Fan Modules (CRU)" at
|
7046442 |
Assembly, dual port, QDR CX3, host channel adapter |
EBO |
|
7064884 |
Heat sink, CPU |
EBO |
See "Servicing Processors (FRU)" at
|
7066824 |
Assembly, drive, 8 TB, 3.5 inch, SAS/7200rpm |
HS |
See "Servicing Storage Drives and Rear Drives (CRU)" at
|
7069337 |
Assembly, backplane, 12X3.5, W/SAS expansion, 2U |
EBO |
See "Servicing the Front and Rear Storage Drive Backplanes (FRU)" at
|
7078070 |
DIMM, 16 GB, RDIMM, DDR4, 2400 |
EBO |
See "Servicing the DIMMS (CRU)" at
|
7085209 |
HBA, 12 Gb SAS PCIe 8-port RAID internal with flash module |
EBO |
See "Servicing the Oracle Storage 12 Gb/s SAS PCIe RAID HBA Card (FRU)" at |
7086345 |
Assembly, super cap, 13.5 volt, 6.4F, SAS3 HBA |
EBO |
See "Servicing the Oracle Storage 12 Gb/s SAS PCIe RAID HBA Card (FRU)" at |
7086346 |
Cable, super cap, 620M, 6-pin, straight, SAS3 HBA |
EBO |
See "Servicing SAS Cables (FRU)" at
|
7090170 |
Flash drive, MLC, OSA ID, USB, 8 GB |
EBO |
See "Servicing the Internal USB Flash Drives (CRU)" at
|
7090698 |
Assembly, 3.2 TB eMLC flash F320 NVMe card |
EBO |
See Oracle Flash Accelerator F320 PCIe Card User Guide at |
7095102 |
CPU, E5-2630 V4, 2.2 G, 85 W, 10 CORE, R-2 (SR206) |
EBO |
See "Servicing Processors (FRU)" at
|
7096185 |
Assembly, indicator, left |
EBO |
See "Servicing the Front LED/USB Indicator Modules (FRU)" at
|
7098504 |
ASM, MOBO tray |
EBO |
Table B-8 lists the replaceable parts for the Oracle Server X5-2L. Unless otherwise noted, the repair procedures are in Oracle Server X5-2L Service Manual.
Note:
All replacement parts listed in the following table are FRUs when covered under Premier Support of Systems warranty.
Table B-8 Replacement Parts for Oracle Server X5-2L Storage Servers
Part Number | Description | Repair Category | Repair Procedure |
---|---|---|---|
350-1719 |
Assembly, 1U-2U Snap-in, slim rail rack |
EBO |
|
370-5621 |
3 volt lithium battery |
EBO |
See "Servicing the Battery (CRU)" at
|
7014226 |
Cable, interlock, 125 mm |
EBO |
See "Servicing SAS Cables (FRU)" at
|
7017231 |
Indicator assembly, right |
EBO |
See "Servicing the Front LED/USB Indicator Modules (FRU)" at
|
7023515 |
Disk backplane assembly, 2 rear |
EBO |
See "Servicing the Front and Rear Storage Drive Backplanes (FRU)" at
|
7044130 |
Power Supply, A258, 1000W, AC Input |
HS |
|
7045042 |
Fan assembly, 2U, 80 x 80, Ferrite, center rotate |
HS |
See "Servicing Fan Modules (CRU)" at
|
7046442 |
Assembly, dual port, QDR CX3, host channel adapter |
EBO |
|
7064884 |
Heat sink, CPU |
EBO |
See "Servicing Processors (FRU)" at
|
7066824 |
Assembly, drive, 4 TB, 3.5 inch, SAS/7200rpm |
HS |
See "Servicing Storage Drives and Rear Drives (CRU)" at
|
7069337 |
Assembly, backplane, 12X3.5, W/SAS expansion, 2U |
EBO |
See "Servicing the Front and Rear Storage Drive Backplanes (FRU)" at
|
7078070 |
DIMM, 8 GB, RDIMM, DDR4, 2133 |
EBO |
See "Servicing the DIMMS (CRU)" at
|
7085209 |
HBA, 12 Gb SAS PCIe 8-port RAID internal with flash module |
EBO |
See "Servicing the Oracle Storage 12 Gb/s SAS PCIe RAID HBA Card (FRU)" at |
7086345 |
Assembly, super cap, 13.5 volt, 6.4F, SAS3 HBA |
EBO |
See "Servicing the Oracle Storage 12 Gb/s SAS PCIe RAID HBA Card (FRU)" at |
7086346 |
Cable, super cap, 620M, 6-pin, straight, SAS3 HBA |
EBO |
See "Servicing SAS Cables (FRU)" at
|
7090170 |
Flash drive, MLC, OSA ID, USB, 8 GB |
EBO |
See "Servicing the Internal USB Flash Drives (CRU)" at
|
7090698 |
Assembly, 1.6 TB eMLC flash F160 NVMe card, Aura 3.0 with LP BRKT |
EBO |
See Oracle Flash Accelerator F160 PCIe Card User Guide at |
7095102 |
CPU, E5-2630 V3, 2.4G, 85W, 8 CORE, R-2 (SR206) |
EBO |
See "Servicing Processors (FRU)" at
|
7096185 |
Assembly, indicator, left |
EBO |
See "Servicing the Front LED/USB Indicator Modules (FRU)" at
|
7098504 |
ASM, MOBO tray |
EBO |
Figure B-7 shows the front view of the Sun Server X4-2L. The hard drives are numbered from left to right, starting in the lower left. The drives in the bottom row are numbers 0, 1, 2, and 3. The drives in the middle row are numbers 4, 5, 6, and 7. The drives in the top row are numbers 8, 9, 10, and 11.
Figure B-7 Front View of Sun Server X4-2L
Figure B-8 shows the rear view of a Sun Server X4-2L storage server.
Table B-9 lists the replaceable parts for the Sun Server X4-2L. Unless otherwise noted, the repair procedures are in Sun Server X4-2L Service Manual.
Note:
All replacement parts listed in the following table are FRUs when covered under Premier Support of Systems warranty.
Table B-9 Replacement Parts for Sun Server X4-2L Storage Servers
Part Number | Description | Repair Category | Repair Procedure |
---|---|---|---|
371-5002 |
USB drive, 4 GB |
EBO |
See "Servicing the Internal USB Flash Drives" in Sun Server X4-2L Service Manual at
|
7014226 |
Cable, interlock, 125 mm |
EBO |
See "Servicing Cables" at
|
7014391 |
Expander assembly, 2U |
EBO |
See "Servicing the SAS Expander Module" at
|
7017231 |
Indicator assembly, right |
EBO |
See "Servicing the Front LED/USB Indicator Modules" at
|
7018701 |
DIMM, 16 GB, DDR3, 1600, 2Rx4, 1.35V |
EBO |
See "Servicing the DIMMS" at
|
7020486 |
DIMM, 8 GB, DDR3, 1600, 2Rx4, 1.35V |
EBO |
See "Servicing the DIMMs" at
|
7020776 |
Heatsink, CPU, 2U, 60 MM FIN, RoHS:YU |
EBO |
See "Servicing Storage Drives and Rear Drives" at
|
7023515 |
Disk backplane assembly, 2 rear |
EBO |
See "Servicing the Front and Rear Storage Drive Backplanes" at
|
7027479 |
Disk backplane assembly, 4-Slot 3.5" RoHS:Y |
EBO |
See "Servicing the Front and Rear Storage Drive Backplanes" at
|
7044130 |
Power Supply, A258, 1000 Watt AC Input |
HS |
|
7045042 |
Fan assembly, 2U, 80 x 80, Ferrite, center_rotate |
HS |
See "Servicing Fan Modules" at
|
7046442 |
Assembly, dual port, QDR CX3, host channel adapter |
EBO |
|
7047503 |
Assembly, 6 GB, SAS RAID disk PCIe HBA, RoHS:Y |
DBO |
See "Servicing Storage Drives and Rear Drives" at
|
7048864 |
Indicator assembly, left, 2U |
EBO |
See "Servicing the Front LED/USB Indicator Modules (FRU)" at
|
7057184 |
Assembly, battery carrier remote |
HS |
|
7058152 |
Assembly, motherboard, X4-2L |
EBO |
See "Servicing the Motherboard Assembly" at
|
7060020 |
Universal upgrade remote battery kit |
EBO |
|
7069200 |
Assembly, 800 GB eMLC flash PCIe card |
EBO |
See "Servicing PCIe Cards" at
|
7069242 |
CPU, E5-2630 v2, 6-core, 2.6 Ghz |
EBO |
See "Servicing Processors" at
|
7070656 |
Disk assembly, 1.2 TB, SAS2 |
HS |
See "Servicing Storage Drives and Rear Drives" at
|
7106353 |
4 TB 7200 rpm SAS HDD with bracket |
DBO |
See "Servicing Storage Drives and Rear Drives" at
|
Table B-10 lists the replaceable parts for the InfiniBand switches used in Recovery Appliance. See "Cables and Cable Accessories for Recovery Appliance" for information about InfiniBand cables.
Note:
All replacement parts listed in the following table are FRUs when covered under Premier Support of Systems warranty.
Table B-10 Replacement Parts for InfiniBand Switches
Part Number | Description | Repair Category | Repair |
---|---|---|---|
300-2143 |
760 watt power supply, RoHS:Y |
HS |
See Sun Datacenter InfiniBand Switch 36 User's Guide at
|
300-2299 |
760 watt AC input power supply |
HS |
See Sun Datacenter InfiniBand Switch 36 User's Guide at
|
350-1312 |
Fan module for Sun Datacenter InfiniBand Switch 36, RoHS:Y |
HS |
See Sun Datacenter InfiniBand Switch 36 User's Guide at
|
350-1566 |
Fan module, 1 RU, Sanace, reverse |
HS |
See Sun Datacenter InfiniBand Switch 36 User's Guide at
|
371-2210 |
CR2032 3 v battery, RoHS:Y |
IR |
See Sun Datacenter InfiniBand Switch 36 User's Guide at
|
541-3495 |
Sun Datacenter InfiniBand Switch 36, RoHS:YL |
IR |
See Sun Datacenter InfiniBand Switch 36 User's Guide at
|
7052970 |
Sun Datacenter InfiniBand Switch 36, RoHS:YL |
IR |
See Sun Datacenter InfiniBand Switch 36 User's Guide at
|
7061031 |
Fan module, 1 RU, Sanace, reverse |
HS |
See Sun Datacenter InfiniBand Switch 36 User's Guide at
|
Table B-11 lists replaceable parts for the Cisco switch used with Recovery Appliance.
Note:
All replacement parts listed in the following table are FRUs when covered under Premier Support of Systems warranty.
Table B-11 Replacement Parts for Cisco Switch
Part Number | Description | Repair Category | Repair |
---|---|---|---|
7023685 |
Cisco Catalyst 4948 switch, RoHS:Y |
IR |
See chapter 3 in Catalyst 4948E and Catalyst 4948E-F Switch Installation Guide at |
7024423 |
Power supply for Cisco Catalyst 4948 switch, RoHS:Y |
HS |
See chapter 4 in Catalyst 4948E and Catalyst 4948E-F Switch Installation Guide at |
7024424 |
Cooling fan for Cisco Catalyst 4948 switch, RoHS:Y |
HS |
See chapter 4 in Catalyst 4948E and Catalyst 4948E-F Switch Installation Guide at |
Table B-12 lists the replacement parts for the power distribution units (PDUs). Given the number of cables and connections, Oracle recommends that you shut down the Recovery Appliance rack when replacing power distribution unit parts.
Note:
All replacement parts listed in the following table are FRUs when covered under Premier Support of Systems warranty.
Table B-12 Replacement Parts for Power Distribution Units
Part Number | Description | Repair Category | Repair |
---|---|---|---|
180-2379 |
13A/250V 90 degree IEC 320 Sheet E to IEC 320 C13 cord, 1 meter, RoHS:Y |
HS |
Not applicable |
180-2380 |
13A/250V 90 degree IEC 320 Sheet E to IEC 320 C13 cord, 2 meter, RoHS:Y |
HS |
Not applicable |
371-4000 |
Three-phase PDU: 15kV,5-Pin, IEC309 32A, 5 PIN 230/400V, 3ph IP44, International, RoHS:Y |
IR |
See "Replacing a Power Distribution Unit" of this guide. |
371-4199 |
Single-phase PDU: 15kVA, with three 30A/250V 2-Pole/3-Wire NEMA L6-30P Plugs, North America, RoHS:Y |
IR |
See "Replacing a Power Distribution Unit" of this guide. |
371-4201 |
Single-phase PDU: 15kVA, with three Blue 32A/240V Splash-proof 2-Pole/3-Wire IEC 60309 Plugs, International, RoHS:Y |
IR |
See "Replacing a Power Distribution Unit" of this guide. |
371-5039 |
Single-phase PDU: 22k VA Hubbell CS8265C PlugNo X-Option |
IR |
See "Replacing a Power Distribution Unit" of this guide. |
371-5040 |
Single-phase PDU: 22k VA Blue 32A IEC 60309 Plug No X-Option |
IR |
See "Replacing a Power Distribution Unit" of this guide. |
7051908 |
Three-phase PDU: 15kVA, IEC309 60A, 4 PIN, 250VAC, 3ph IP67, North America, RoHS:Y |
IR |
See "Replacing a Power Distribution Unit" of this guide. |
Table B-13 lists the replacement cables and cable accessories for Recovery Appliance.
Note:
All replacement parts listed in the following table are FRUs when covered under Premier Support of Systems warranty.
Table B-13 Replacement Cables for Recovery Appliance
Part Number | Description | Repair Category | Repair |
---|---|---|---|
350-1287 |
Slim rail, CMA, 1U-2U for a storage server |
EBO |
|
350-1546 |
Cable management arm (CMA) 1U, RoHS:Y for compute server |
DBO |
|
350-1519 |
Serial cable kit, RoHS:Y with the following:
|
HS |
See Sun Datacenter InfiniBand Switch 36 User's Guide at
|
350-1637 |
Label assembly, EV2, 2-way, upgrade, label |
HS |
|
350-1638 |
Label assembly EV2, 3-way, service upgrade, label |
HS |
|
350-1639 |
Label assembly EV2, 4-way, service upgrade, label |
HS |
|
350-1640 |
Label assembly EV2, 5-way, service upgrade, label |
HS |
|
350-1641 |
Label assembly EV2, 6-way, service upgrade, label |
HS |
|
350-1642 |
Label assembly EV2, 7-way, service upgrade, label |
HS |
|
350-1643 |
Label assembly EV2, 8-way, service upgrade, label |
HS |
|
530-4445 |
QSFP InfiniBand passive copper cable, 10 GbE, 3 m, RoHS:Y |
HS |
See Sun Datacenter InfiniBand Switch 36 User's Guide at
Note: There is a loss of redundancy when replacing cables. |
530-4446 |
QSFP InfiniBand passive copper cable, 10 GbE, 5 m, RoHS:Y |
HS |
See Sun Datacenter InfiniBand Switch 36 User's Guide at
Note: There is a loss of redundancy when replacing cables. |
530-4403 |
4x QSFP copper QDR InfiniBand cable, 2 m, RoHS:Y |
HS |
See Sun Datacenter InfiniBand Switch 36 User's Guide at
Note: There is a loss of redundancy when replacing cables. |
530-4404 |
4x QSFP copper QDR InfiniBand cable, 3 m, RoHS:Y |
HS |
See Sun Datacenter InfiniBand Switch 36 User's Guide at
|
530-4415 |
4x QSFP copper QDR InfiniBand cable, 5 m, RoHS:Y |
HS |
See Sun Datacenter InfiniBand Switch 36 User's Guide at
|
530-4432 |
Ethernet cable, Cat 5/5E, RJ45 to RJ45, 7 foot, blue, RoHS:Y |
HS |
See Catalyst 4948E and Catalyst 4948E-F Switch Installation Guide at |
530-4433 |
Ethernet cable, Cat 5/5E, RJ45 to RJ45, 10 foot, red, RoHS:Y |
HS |
See Catalyst 4948E and Catalyst 4948E-F Switch Installation Guide at |
530-4434 |
Ethernet cable, Cat 5/5E, RJ45 to RJ45, 7 foot, red, RoHS:Y |
HS |
See Catalyst 4948E and Catalyst 4948E-F Switch Installation Guide at |
530-4435 |
Ethernet cable, Cat 5/5E, RJ45 to RJ45, 10 foot, black, RoHS:Y |
HS |
See Catalyst 4948E and Catalyst 4948E-F Switch Installation Guide at |
530-4436 |
Ethernet cable, Cat 5/5E, RJ45 to RJ45, 7 foot, black, RoHS:Y |
HS |
See Catalyst 4948E and Catalyst 4948E-F Switch Installation Guide at |
530-4437 |
Ethernet cable, Cat 5/5E, RJ45 to RJ45, 7 foot, orange, RoHS:Y |
HS |
See Catalyst 4948E and Catalyst 4948E-F Switch Installation Guide at |
530-4438 |
Ethernet cable, Cat 5/5E, RJ45 to RJ45, 10 foot, black, RoHS:Y |
HS |
See Catalyst 4948E and Catalyst 4948E-F Switch Installation Guide at |
530-4444 |
QSFP to QSFP Passive Copper Cable, 1 m, RoHS:Y |
HS |
See Sun Datacenter InfiniBand Switch 36 User's Guide at
|
530-4445 |
QSFP passive copper cable, 10 GE, 3 m |
HS |
See Sun Datacenter InfiniBand Switch 36 User's Guide at
|
530-4502-01 |
Ethernet cable, Cat 5/5E, 10 foot, blue, RoHS:Y |
HS |
See Catalyst 4948E and Catalyst 4948E-F Switch Installation Guide at |
7015400 |
Power cable, jumper, SR2, 2m C14RA, 10A, C13 |
HS |
See "Replacing a Power Distribution Unit" of this guide. |
7042273 |
Slim rail, cable management arm, 1U-2U for a storage server |
EBO |
|
7102869 |
Passive fiber InfiniBand cable, 10 m, RoHS:Y |
HS |
Note: Purchase two QSFP SR Transceivers (Part Number X2124A-N) for each passive fiber cable. |
7102870 |
Passive fiber InfiniBand cable, 20 m, RoHS:Y |
HS |
See Sun Datacenter InfiniBand Switch 36 User's Guide at
Note: Purchase two QSFP SR Transceivers (Part Number X2124A-N) for each passive fiber cable. |
7102871 |
Passive fiber InfiniBand cable, 50 m, RoHS:Y |
HS |
See Sun Datacenter InfiniBand Switch 36 User's Guide at
Note: Purchase two QSFP SR Transceivers (Part Number X2124A-N) for each passive fiber cable. |