This section lists example technologies for the private cluster interconnect and for the data paths and their various distance limits. In some cases, it is possible to extend these limits. For more information, ask your Oracle representative.

Cluster Interconnect Technologies

The following table lists example node-to-node link technologies and their limitations.

Table 8  Campus Cluster Interconnect Technologies and Distance Limits
Link Technology
Maximum Distance
Comments
100 Mbps Ethernet
100 meters per segment
Unshielded twisted pair (UTP)
1000 Mbps Ethernet
100 meters per segment
UTP
1000 Mbps Ethernet
260 meters per segment
62.5/125 micron multimode fiber (MMF)
1000 Mbps Ethernet
550 meters per segment
50/125 micron MMF
1000 Mbps Ethernet (FC)
10 kilometers at 1 Gbps
9/125 micron single-mode fiber (SMF)
DWDM
200 kilometers and up
Other
Consult your Oracle representative

Always check your vendor documentation for technology-specific requirements and limitations.

Storage Area Network Technologies

The following table lists example link technologies for the cluster data paths and the distance limits for a single interswitch link (ISL).

Table 9  ISL Limits
Link Technology
Maximum Distance
Comments
FC short-wave gigabit interface converter (GBIC)
500 meters at 1 Gbps
50/125 micron MMF
FC long-wave GBIC
10 kilometers at 1 Gbps
9/125 micron SMF
FC short-wave small form-factor pluggable (SFP)
300 meters at 2 Gbps
62.5/125 micron MMF
FC short-wave SFP
500 meters at 2 Gbps
62.5/125 micron MMF
FC long-wave SFP
10 kilometers at 2 Gbps
9/125 micron SMF
DWDM
200 kilometers and up
Other
Consult your Oracle representative