Install the Fan Assembly Door


Note -  The procedures in this section should be used for systems configured with twelve 3.5-inch storage drives or twenty-four 2.5-inch storage drives. If your system is configured with eight 2.5-inch drives, see Install the Disk Cage Cover.
  1. Place the fan assembly door on the chassis and slightly over the fan assembly.
  2. Slide the fan assembly door forward and under the lip of the forward top cover until it latches into place [1].
    image:Figure showing the installation of the fan assembly door.
  3. Use a No. 2 Phillips screwdriver to install and secure the fan assembly door [2].
    • If your system is configured with twelve 3.5-inch storage drives, install and tighten the two screws on each side of the chassis and the three screws on top of the chassis.
    • If your system is configured with twenty-four 2.5-inch storage drives, install and tighten the two screws on each side of the chassis.