C H A P T E R  3

Monitoring the Server Module Using the ELOM Web GUI

This chapter provides information about how to use the ELOM web GUI and the Sun Blade X6450 Server Module software to monitor your server.

See the following sections:


Using the Web GUI

The web GUI allows you to monitor and manage, configure and maintain local and remote systems, using a browser. For information about managing, configuring and maintaining the server using the web GUI, see Chapter 4.

You can also monitor and manage, configure and maintain the server remotely by redirecting the server’s console to a remote workstation or laptop. For information about remote configuration, see Chapter 5.

Web GUI Tasks

Some of the common tasks you can perform using the web GUI include:

Configure Connection Methods:

Monitor and Manage:

Manage and Modify System Variables:

Browser and Software Requirements

The web GUI has been tested successfully with recently released Mozillatrademark Firefox, and Internet Explorer browsers, and may be compatible with other browsers.

The ELOM product is preinstalled on the Sun server. However, you need Javatrademark software on the client to perform redirection as described in Chapter 10.


Accessing the System Using a Browser

The ELOM boots automatically when the server module is inserted into a powered chassis. This usually occurs within one minute. However, if the management Ethernet is not connected, or if the ELOM's Dynamic Host Configuration Protocol (DHCP) process fails due to the absence of a DHCP server on the management network, the ELOM might take a few minutes longer to boot.



Note - Disabling the use of the browser proxy server (if one is used) for access to the management network might speed up the response time.



procedure icon  To Access the System Using a Browser

1. To access the web GUI, enter the IP address of the ELOM in your browser.

The login screen appears.

2. Enter an ELOM user name and password.

Only a user account with administrator privileges has access to all the ELOM menus and screens. If this is the first log-in, use the default user account:

username: root
password: changeme

3. Click Log In.

The main menu screen appears.

To log out of the web GUI:

single-step bullet  Click the Log Out button.

The Log Out button is located at the top right of the interface screen.

Viewing the System From the Web GUI

When logged in to the ELOM, you use the web GUI to access screens that allow you to monitor and manage the server module. FIGURE 3-1 FIGURE 3-1 shows the web GUI’s main screen.

FIGURE 3-1 ELOM System Information Screen


A screenshot showing the ELOM Server Board Version screen.

The six main menu tabs and the submenu screens are listed in TABLE 3-1:


TABLE 3-1 ELOM Tab Detail Choices

Main Tab

Sub-level Tab

 

Where to Find Details

System Information

 

 

Viewing System Information

 

Versions

 

Viewing System Information

 

 

Server Board

 

 

 

BMC Version

 

 

Session Time-Out

 

Setting Session Timeout

 

Components

 

Viewing Component Information

 

 

CPU

 

 

 

Memory

 

 

 

NIC

 

System Monitoring

 

 

 

 

Sensor Reading

 

Monitoring the System

 

 

Summary

 

 

 

Temperature

 

 

 

Voltage

 

 

 

Chassis Status

 

 

Event Logs

 

Viewing and Managing the Event Log

 

 

View Event Logs

 

 

 

Save Event Logs

 

 

 

Clear Event Logs

 

 

Locator Indicator

 

Managing the Locator Indicator and Fault LED

 

Fault LED

 

Refer to your service manual

Configuration

 

 

 

 

Network

 

To View NIC Information

 

Email Notification

 

Configuring Email Notification

 

Platform Event Filter

 

Setting the Time

 

Set Time

 

 

 

SSL Certificate

 

Configuring the SSL Certificate

 

SNMP

 

Configuring SNMP

 

 

 

 

User Management

 

 

 

 

User Account

 

To Add a User

 

ADS Configuration

 

Configuring ADS

Remote Control

 

 

Starting the Remote Console Application

 

Remote Power Control

 

Controlling Server Power

 

Hotkey Setup

 

Chapter 5

Maintenance

 

 

 

 

Firmware Upgrade

 

Updating the Firmware

 

Reset BMC

 

Resetting the Baseboard Management Controller


The following section describes how to monitor the server using the browser and the Embedded Lights Out Manager software.


Viewing System Information

The System Information tab provides information about server board and system components, such as the service processor (SP), the CPUs, the memory, and the network interface card (NIC). Details are found in the Versions and Components submenu tabs.



Note - The service processor (SP) is also referred to as the baseboard management controller or BMC. Wherever BMC is mentioned, consider it different terminology for the SP.



procedure icon  To View System Information

single-step bullet  On the main menu, click the System Information tab.

The System Information submenu appears, allowing you to view the Versions, Session Time-Out, and Components submenu tabs.

Viewing Version Information

The Version screen allows you to view information about the server board, the chassis board and the BMC (SP). Using the Version submenu screen, you can view board-specific information for the server and chassis boards, such as manufacturer, manufacture date, serial numbers, and part numbers. Using the BMC version information screen, you can view information related to the SP, such as device ID, firmware revision, and IPMI and CPLD version numbers.


procedure icon  To View Server and Chassis Board Information

single-step bullet  From the Versions submenu, select the Server Board Version tab.

The Server Board Version screen appears. The screen displays information about the server board and the chassis board. TABLE 3-2 shows a sample of the server board information:


TABLE 3-2 Sample Server Board Information

Description

Server Board Information

 

BIOS Version:

1ADP1017

 

Manufacture Date:

2008/05/11 09:12

 

Manufacturer:

Sun Microsystems, Inc.

 

Product:

Sun Blade X6450 Server Module

 

Serial Number:

qtfmcs7060094

 

Part Number:

375-3343-01

 

Slot ID:

8


 


TABLE 3-3 Sample Chassis Board Information

Description

Chassis Board Information

 

Product Part Number:

123-4567-8

 

Product Serial Number:

012345678

 

Product Asset Tag:

44

 

Chassis Serial Number:

12345678-12345678

 

Chassis Part Number

333-4444-1



procedure icon  To View BMC Version Information

single-step bullet  From the Versions submenu, select the BMC Version tab.

The BMC Version screen appears. The screen displays information about the BMC installed in the system, and presents the information in a tabular format. For example, TABLE 3-4 shows a sample of the BMC version information:


TABLE 3-4 Sample BMC Version Screen

Description

BMC Board Information

 

Device ID

5

 

Device Revision

0

 

Firmware Revision

4.0.11

 

IPMI Revision

2.0

 

CPLD version

5041


Viewing Component Information

The Component Information submenu tab contains the screens that you can use to monitor and troubleshoot the server module’s critical components. Using these screens you can view the status of the CPUs and DIMMs. Use these screens in conjunction with the Service Action Required LED to further investigate service-related issues.


procedure icon  To View CPU Information

single-step bullet  From the System Information menu, click the Components submenu tab, and then select CPU.

The CPU information screen appears. The CPU information is presented in a tabular format (see TABLE 3-5). A separate table of information is available for each of the server’s CPU locations, regardless if a CPU is installed or not.


TABLE 3-5 Sample CPU Information

Description:

CPU Information

 

CPU

0

 

Status:

Enable

 

Socket:

CPU0

 

Manufacturer:

Intel

 

Model:

E7340

 

Frequency:

2400 MHz



procedure icon  To View Memory Information

single-step bullet  From the System Information menu, click the Components submenu tab, and then select Memory.

The Memory submenu screen appears. The screen displays information about each of the DIMMs installed in your server. The memory information is presented in a tabular format (see TABLE 3-6).


TABLE 3-6 Sample Memory Information

Description

Memory Information

 

Memory Module

1

 

Status:

Ok

 

Socket:

DIMM_A0

 

Module Size:

2048MB

 

Type:

FBDIMM

 

Frequency

533MHz



procedure icon  To View NIC Information

single-step bullet  From the System Information menu, click the Components submenu tab, and then select NIC.

The NIC submenu screen appears. The screen displays information about the network interface card installed in your server. The NIC information is presented in a tabular format (see TABLE 3-7).


TABLE 3-7 Sample of NIC Information

Description:

Network Interface Card 0 Information

 

Manufacturer:

Intel

 

Product Name:

ESB Dual Port GbE NIC

 

Product Part Number:

6312

 

Product Serial Number:

00:16:36:F1:67:34

 

Port Number:

02

 

MAC Address 1:

00:16:36:F1:67:34

 

MAC Address 2:

00:16:36:F1:67:35



Monitoring the System

Sensors placed throughout the system provide information about the state of critical server hardware. The sensors allow the system to monitor temperature, voltage, and operational status. Using the System Monitoring submenu screens you can view the these sensors, and monitor the health of your server’s critical components. For example, you can check the temperature of each CPU and the voltage level of the system’s DC voltage lines.

The System Monitoring submenu screens also allow you to view and manage the system log, the System Indicator LED, and the Fault LED. For information about the System Indicator LED and the Fault LED, see Chapter 4.


procedure icon  To Monitor the System

single-step bullet  On the main menu, click System Monitoring.

The System Monitoring submenu appears, allowing you to view the Sensor Reading, Event Logs, System Indicator, and Fault LED tabs.

Reading Sensors

The Sensor Reading Tab provides viewing and monitoring access to the Sensor Summary, the Temperature, Voltage, and Chassis Status screens.


procedure icon  To Read Sensors

single-step bullet  From the System Monitoring tab, click the Sensor Reading Tab.

The Sensor Reading tab allows you to select the Summary, Temperature, Voltage, and Chassis Status tabs.


procedure icon  To View a Sensor Summary

single-step bullet  From the Sensor Reading submenu tab, select the Summary tab.

The Summary screen appears. It provides an overview of the status of the system sensors. The screen provides the status of the Fault LED, the server’s power status, the temperature status of all critical components, and the status of each of the monitored voltage lines.


procedure icon  To Monitor Temperatures

single-step bullet  From the Sensor Reading submenu tab, select the Temperature tab.

The Temperature screen appears. The screen provides the status, the actual temperature, and the upper critical and non-critical temperature thresholds for each system-critical component. The Temperature submenu screen displays the information in a tabular format. It provides a separate table for each component. TABLE 3-8 shows a sample of the temperature monitoring readings for CPU 0.


TABLE 3-8 Sample Temperature Monitor Readings

Description:

CPU Temp

 

Upper noncritical threshold is readable:

93.0

 

Upper critical threshold is readable:

95.0

 

Sensor Reading:

54.0

 

Status:

ok


A similar panel is repeated for each monitored entity.


procedure icon  To Monitor Voltages

single-step bullet  From the Sensor Reading submenu, select the Voltage tab.

The Voltage screen appears. The screen provides the status, the actual voltage reading, and the upper critical and non-critical voltage thresholds for each of the monitored voltage lines. The Voltage submenu screen displays this information in a tabular format. TABLE 3-9 shows a sample of this information for P_VCCP0.


TABLE 3-9 Sample of Voltage Information

Description

P_VCCP0

 

Lower non-critical threshold is readable:

0.000

 

Lower critical threshold is readable:

0.000

 

Upper non-critical threshold is readable:

1.342

 

Upper critical threshold is readable:

1.342

 

Sensor Reading:

1.147

 

Status:

ok



procedure icon  To Monitor the Chassis Status

single-step bullet  From the Sensor Reading submenu, select the Chassis Status tab.

The Chassis Status submenu screen appears, showing the actual senor readings for the critical components of the chassis. These components include the chassis fans (RPM), the power supplies (voltage, current, and power), and the chassis cabinet (ambient temperature). The information is presented a tabular format showing the name, the reading, and the unit of measurement. TABLE 3-10 shows a sample of the information presented in the Chassis Status screen.


TABLE 3-10 Sample of the Chassis Status Information

Name

Reading

Unit

fm0.f0.speed

2900.000

RPM

ps0.t_amb

24.000

degrees

ps0.V12V

12.008

Volts

ps1.fan_speed

11940.000

RPM

ps1.l12V_0

34.173

Amps

ch.tamb_0

26.000

degrees


Viewing and Managing the Event Log

The Event Log screen allows you to view and manage the System Event Log (SEL). The SEL is a record of event occurrences. To record events in the SEL, you must have previously determined which events require logging. See Setting the Time.


procedure icon  To View and Manage the Event Log

single-step bullet  From the System Monitoring tab on the main menu, click the Event Logs submenu tab.

The Event Logs submenu screen appears, and the View Event Logs, Save Event Logs, and Clear Event Logs submenus become available.


procedure icon  To View the Event Logs

single-step bullet  From the Event Logs submenu, select View Event Logs.

The system event log appears. Each entry in the log represents an action that occurred on the system. The system lists each action, rating the action’s severity, providing time-stamp, and describing the event. The information is presented in a tabular format.


procedure icon  To Save the Event Log

You may want to save the event log for administrative or diagnostic purposes.

1. From the Event Logs submenu, click the Save Event Logs tab.

The Save Event Log screen appears.

2. Click the Save Event Log button to prompt the browser to ask you where to save a copy of the event log.


procedure icon  To Clear the Event Log

The Event Log may need to be cleared to signify a fresh procedure, or to identify system performance under load.

1. From the Event Log menu, choose Clear Event Log.

2. Click the Clear Event Log button to start a fresh event log.