| Sun SPARC Enterprise T1000 Server Installation Guide
|
    |
Configuring the Network Management Port
|
If your server uses Sun system firmware 6.2 or subsequent compatible versions, do not perform the following configuration. Your ALOM CMT system controller network management port is preconfigured at the factory.
If your server uses an earlier version of firmware than Sun system firmware 6.2, you must configure the network management port before you can use it.
This appendix includes the following topic:
Configuring the System Controller Network Manager Port
To Configure the System Controller Network Management Port
|
To access the system controller using the network for the first time, you must first configure the SC network management port through the SC serial management port.
You set these network parameters according to the specific details of your network configuration:
- if_network - Specified whether the SC is on the network or not
- netsc_ipaddr - IP address of the system controller
- netsc_ipgateway - IP address of the gateway for the subnet
- netsc_ipnetmask - Netmask for the system controller subnet
|
Note - For more information on configuring ALOM CMT, refer to the Advanced Lights Out Management (ALOM) CMT Guide.
|
To configure these parameters you must use the setsc command. The usage is:
1. Set the netmask for the system controller.
sc> setsc netsc_ipnetmask 255.255.255.0
|
This example uses 255.255.255.0 to set the netmask. Your network environment subnet might require a different netmask. Use a netmask number most appropriate to your environment.
2. Set the IP address for the system controller.
sc> setsc netsc_ipaddr service-processor-IPaddr
|
3. Set the IP address for the system controller gateway.
sc> setsc netsc_ipgateway gateway-IPaddr
|
4. Set the if_network parameter to true.
sc> setsc if_network true
|
5. Use the showsc command to verify that the parameters were set correctly.
The showsc command displays all the configuration parameters and their values, as shown in the example below.
|
Note - The network addresses and parameters shown in the examples are for illustration purposes only. The four parameters marked with asterisks must be set according to the specific details of your network configuration for the network management port to function properly.
|
sc> showsc
Advanced Lights Out Manager CMT v1.x
parameter value
--------- -----
if_network* true
if_connection ssh
if_emailalerts false
netsc_dhcp true
netsc_ipaddr* xxx.xxx.xxx.xxx
netsc_ipnetmask* 255.255.255.0
netsc_ipgateway* xxx.xxx.xxx.xx
mgt_mailhost
mgt_mailalert
sc_customerinfo
sc_escapechars #.
sc_powerondelay false
sc_powerstatememory false
sc_clipasswdecho true
sc_cliprompt sc
sc_clitimeout 0
sc_clieventlevel 2
sc_backupuserdata true
diag_trigger power-on-reset error-reset
diag_verbosity normal
diag_level max
diag_mode normal
sys_autorunonerror false
ser_baudrate 9600
ser_parity none
ser_stopbits 1
ser_data 8
netsc_enetaddr xx:xx:xx:xx:xx:xx
sys_enetaddr yy:yy:yy:yy:yy:yy
|
| Sun SPARC Enterprise T1000 Server Installation Guide
|
820-0018-10
|
    |