A P P E N D I X  A

System Specifications

This Appendix contains the following specifications for the Sun Fire X2200 M2 server.


A.1 Physical Specifications

TABLE A-1 lists the physical specifications for the Sun Fire X2200 M2 server


TABLE A-1 Sun Fire X2200 M2 Server Physical Specifications

Specification

British

Metric

Width

16.8 inches

425.5 mm

Depth

25 inches

633.7 mm

Height

1.69 inches

43 mm

Weight (max.)

24.64 lbs

11.6 kg



A.2 Power Specifications

Maximum continuous power is 450 W. Other specifications are shown in the following tables


TABLE A-2 Input Voltage Range

Voltage Ranges

Minimum

Nominal

Maximum

Units

Range 1

90

115

132

Vms

Range 2

180

230

264

Vms



TABLE A-3 Input Frequency

Frequency Ranges

Minimum

Nominal

Maximum

Units

Range 1

57

60

63

Hz

Range 2

47

50

53

Hz



TABLE A-4 Input Current

Current Type

Values

Maximum input current

8.0 Amps max @ 90Vac; 4.0 Amps max @ 180 Vac, full load

Maximum measured inrush current

36 Amps



A.3 Environmental Specifications

Environmental specifications for the Sun Fire X2200 M2 server are shown in TABLE A-5.


TABLE A-5 Sun Fire X2200 M2 Server Environmental Specifications

Specification

State

British

Metric

Humidity

Operating

7%-93% RH non-condensing, 80.6˚ F max wet bulb

7%-93% RH non-condensing, 38˚ C max wet bulb

 

Nonoperating

93% RH, non-condensing, 100.4˚ F max wet bulb

93% RH, non-condensing, 43˚ C max wet bulb

Vibration

Operating

0.12 G x-y, 0.17 G z;
5-500 Hz sine

 

 

Nonoperating

0.3 G x-y, 0.6 G z;
5-500 Hz sine

 

Shock

Operating

4.5 G to 3.5 G;
11 msec. half-sine

 

Temperature

Operating

36˚ F to 100˚ F

2˚ C to 38˚ C

 

Nonoperating

-40˚ F to 154˚ F

-40˚ C to 68˚ C

Maximum operating temperature derating

 

-1.8˚ F for every 985 ft. in altitude

-1˚ C for every 300 m in altitude

Altitude

Operating

max 9,843 ft

max 3,000 m


 


A.4 Serial Connector Pin Assignments

The serial port connector is a DB-9 type connector located on the back panel.

FIGURE A-1 Serial Port Connector Pin Configuration


 


TABLE A-6 Serial Port Connector Pin Assignments

Pin

Signal

Description

1

DCD

Carrier detect

2

RXD

Receive data

3

TXD

Transmit data

4

DTR

Data terminal ready

5

GND

Ground

6

DSR

Data set ready

7

RTS

Request to send

8

CTS

Clear to send

9

RI

Ring indicator