This appendix lists the specifications for the Ultra 40 and Ultra 40 M2 workstations. Topics include:
A.1 Physical Specifications
TABLE A-1 lists the physical specifications of the Sun Ultra 40 and Ultra 40 M2 workstation.
TABLE A-1 Sun Ultra 40 and Ultra 40 M2 Workstation Physical Specifications
Length
|
Width
|
Height
|
Weight
|
22.4 in.
(569 mm)
|
8.1 in.
(205 mm)
|
17.5 in. (445 mm)
|
49.6 lbs
(22.5 kgs)
|
If you replace the workstation enclosure, allow adequate airflow from front to rear. The enclosure interior dimensions should be no less than those in TABLE A-2.
TABLE A-2 Enclosure Interior Dimensions for the Sun Ultra 40 and Ultra 40 M2 Workstation.
Length
|
Width
|
Height
|
22 in.
(558 mm)
|
8.1 in.
(205 mm)
|
17.5 in. (445 mm)
|
A.2 Electrical Specifications
TABLE A-1 lists electrical specifications for the Sun Ultra 40 and Ultra 40 M2 workstation.
TABLE A-3 Sun Ultra 40 and Ultra 40 M2 Workstation Electrical Specifications
Specification
|
Value
|
Voltage
|
100/ 110-127/200-240 VAC
|
Current
|
13/12/7 Amps
|
Wattage
|
1000 Watts (maximum)
|
Frequency
|
50-60 Hz
|
A.3 Acoustic Specifications
TABLE A-4 lists acoustic specifications for the Sun Ultra 40 and Ultra 40 M2 workstation.
Note - Acoustic specifications are configuration dependent.
|
TABLE A-4 Sun Ultra 40 and Ultra 40 M2 Workstation Acoustic Specifications
Specification
|
System State
|
Value
|
Sound power
|
Operating with HDD
|
4.9 Bels (approximate)
|
|
Idle
|
4.7 Bels (approximate)
|
Acoustics
|
Operating with HDD or ODD
|
Lpam = 34 dba
|
|
Idle
|
Lpam = 33 dba
|
A.4 Environmental Requirements
TABLE A-5 lists environmental requirements for the Sun Ultra 40 and Ultra 40 M2 workstation.
TABLE A-5 Sun Ultra 40 and Ultra 40 M2 Workstation Environmental Requirements
Specification
|
Value
|
Temperature
|
41˚ to 95˚ F (5˚ to 35˚ C) operating
-40˚ to 149˚ F (-40˚ to 65˚ C) nonoperating
|
Humidity
|
7 - 93% RH (noncondensing) operating
93% RH (noncondensing) nonoperating
|
Pressure
|
9.43 PSI (65 KPa), 95˚ F (35˚ C) operating
3.62 PSI (25 KPa), 77˚ F (25˚ C) nonoperating
|
A.5 Shock and Vibration Specifications
TABLE A-6 lists vibration specifications for the Sun Ultra 40 Workstation.
TABLE A-6 Sun Ultra 40 and Ultra 40 M2 Workstation Shock and Vibration Specifications
Constraint
|
Operating
|
Nonoperating
|
Shock
|
4.5 G, 11 msec, half sine
|
33 G, 11 msec, sine
|
Vibration
|
0.25 G^2/Hz random,
5 to 500 Hz (0.70 Grms)
|
1.2 G^2/Hz random,
5 to 500 Hz (1.11 Grms)
|
Drop
|
N/A
|
1.97 in. (50 mm)
|
Sun Ultra 40 Workstation Service Manual
|
820-0123-13
|
|
Copyright © 2008, Sun Microsystems, Inc. All Rights Reserved.