JavaScript is required to for searching.
Skip Navigation Links
Exit Print View
Sun Fire X4800 Server Service Manual
search filter icon
search icon

Document Information

Using This Documentation

Product Information Web Site

Documentation and Feedback

About This Documentation (PDF and HTML)

Contributors

Change History

Sun Fire X4800 Server Service Manual Overview

Server and Component Overview

Sun Fire X4800 Server Overview

Component Overviews

Power and Reset

Power Modes

Power Button and Power OK LED

How to Power On the Server

How to Power Off the Server

Controlling Server Power Remotely

Removing and Installing Components

Preparing for Service and Operation

Removal and Installation Procedures

Removing and Installing a Power Supply (CRU)

Removing and Installing a Hard Drive (CRU)

Removing and Installing a Hard Drive Filler

Replacing the Hard Drive Backplane (FRU)

Adding, Removing, and Installing a CMOD (CRU)

How to Add a CPU Module (CMOD) to the Server Using the Upgrade Kit

How to Remove a CPU Module (CMOD)

How to Remove the CPU Module (CMOD) Cover

How to Install the CPU Module (CMOD) Cover

How to Install a CPU Module (CMOD)

How to Verify CPLD Versions

CPU Module (CMOD) Designation and Population Rules

Removing and Installing a CMOD Filler

How to Replace the CMOD Battery (CRU)

Removing and Installing DIMMs (CRU)

DIMM Population Rules

Removing and Installing a RAID Expansion Module (CRU)

How to Replace the RAID Expansion Module Battery (CRU)

Removing and Installing a Fabric Expansion Module (CRU)

Replacing a CPU and Heatsink Assembly (FRU)

Removing and Installing a Fan Module (CRU)

Replacing a Fan Module Controller Board (FRU)

Removing and Installing a NEM or a NEM Filler (CRU)

Removing and Installing a PCIe EM (CRU)

Removing and Installing the Service Processor Module (CRU)

Removing and Installing the Multi port Cable

Removing and Installing the Subassembly Module (FRU)

Sun Fire X4800 Server Service Procedures, and Information

Managing FRUID Information

Firmware Information and Procedures

How to Access the BIOS Setup Utility

Updating the CPLD

Component LED Locations and Meanings

Sun Fire X4800 Server Specifications

Physical Specifications

Power Specifications

Environmental Specifications

Index

How to Verify CPLD Versions

All CMODs must have identical CPLD levels. After installing a CMOD, you must verify the CPLD levels for all CMODs in the chassis.

Before You Begin

All CMODs in the chassis must be installed, and the chassis must be in standby power mode. The green LED on all CMODs must be steady ON.

For more on standby power, see Power Modes.

  1. Logon to the ILOM.
  2. Enter the following command for each node in the chassis:

    show /SYS/BLn/CPLD

    where n is the node number.

  3. Verify that all nodes return the same value.

    If all nodes do not return the same value, contact Oracle service.

See Also