C H A P T E R  1

Initial Inspection of the Server

This chapter includes the following topics:


Service Troubleshooting Flowchart

Use the following flowchart as a guideline for using the information in this book to troubleshoot the server.


TABLE 1-1 Troubleshooting Flowchart

To perform this task

Refer to this section

Gather initial service information.

Gathering Service Information

Investigate any power-on problems.

Troubleshooting Power Problems

Perform external visual inspection and internal visual inspection.

Externally Inspecting the Server

Internally Inspecting the Server

Troubleshoot DIMM problems.

Troubleshooting DIMM Problems

View BIOS event logs.

Viewing Event Logs

View service processor logs and sensor information.

Using the ILOM Service Processor Web Interface to View System Information

Run diagnostics software.

Using Pc-Check Diagnostics Software

Using SunVTS Diagnostic Software



Gathering Service Information

The first step in determining the cause of a problem with the server is to gather information from the service-call paperwork or the onsite personnel. Use the following general guideline steps when you begin troubleshooting.

To gather service information:

1. Collect information about the following items:

2. Document the server settings before you make any changes.

If possible, make one change at a time in order to isolate potential problems. In this way, you can maintain a controlled environment and reduce the scope of troubleshooting.

3. Take note of the results of any change that you make. Include any errors or informational messages.

4. Check for potential device conflicts before you add a new device.

5. Check for version dependencies, especially with third-party software.


System Inspection

Controls that have been improperly set and cables that are loose or improperly connected are common causes of problems with hardware components.

Troubleshooting Power Problems

An intrusion switch on the motherboard automatically shuts down the server power to standby mode when the cover is removed.

Externally Inspecting the Server

To perform a visual inspection of the external system:

1. Inspect the external status indicator LEDs, which can indicate component malfunction.

For the LED locations and descriptions of their behavior, see External Status Indicator LEDs.

2. Verify that nothing in the server environment is blocking air flow or making a contact that could short out power.

3. If the problem is not evident, continue with the next section, Internally Inspecting the Server.

Internally Inspecting the Server

To perform a visual inspection of the internal system:

1. Choose a method for shutting down the server from main power mode to standby power mode. See FIGURE 1-1, FIGURE 1-2, and FIGURE 1-3 for the location of the power button for each platforn.



caution icon Caution - Performing an emergency shutdown can cause open files to become corrupt. Use an emergency shutdown only when necessary.


When main power is off, the Power/OK LED on the front panel will begin flashing, indicating that the server is in standby power mode.



caution icon Caution - When you use the Power button to enter standby power mode, power is still directed to the service processor and power supply fans, indicated when the Power/OK LED is flashing. To completely power off the server, you must disconnect the AC power cords from the back panel of the server.


FIGURE 1-1 X4150 Server Front Panel Power Button


Graphic showing the Sun Fire X4150 front panel.

FIGURE 1-2 X4250 Server Front Panel Power Button


Graphic showing the Sun Fire X4250 front panel.

FIGURE 1-3 X4450 Server Front Panel Button


Graphic showing the Sun Fire X4250 front panel.

2. Remove the server cover.

For instructions on removing the server cover, refer to your server’s service manual.

3. Inspect the internal status indicator LEDs. These can indicate component malfunction.

For the LED locations and descriptions of their behavior, see Internal Status Indicator LEDs.



Note - The server must be in standby power mode to view the internal LEDs.


4. Verify that there are no loose or improperly seated components.

5. Verify that all cable connectors inside the system are firmly and correctly attached to their appropriate connectors.

6. Verify that any after-factory components are qualified and supported.

For a list of supported PCI cards and DIMMs, refer to your server’s service manual.

7. Check that the installed DIMMs comply with the supported DIMM population rules and configurations, as described in the service manual for your product.

8. Replace the server cover.

9. To restore the server to main power mode (all components powered on), use a ballpoint pen or other nonconductive stylus to press and release the Power button on the server front panel. See FIGURE 1-1, FIGURE 1-2, and FIGURE 1-3.

When main power is applied to the full server, the Power/OK LED next to the Power button lights and remains lit.

10. If the problem with the server is not evident, you can obtain additional information by viewing the power-on self test (POST) messages and BIOS event logs during system startup. Continue with Viewing Event Logs.