JavaScript is required to for searching.
Skip Navigation Links
Exit Print View
Sun Datacenter InfiniBand Switch 36 Topic Set
search filter icon
search icon

Document Information

Using This Documentation

Related Documentation

Documentation, Support, and Training

User's Guide

Installing the Switch

Understanding Switch Specifications

Routing Service Cables

Understanding InfiniBand Cabling

Preparing for Installation

Verify Shipping Carton Contents

Route the InfiniBand Cables

Install the Switch in the Rack

Powering On the Switch

Connecting InfiniBand Cables

Verifying the InfiniBand Fabric

Administering the Switch

Troubleshooting the Switch

Understanding Administrative Commands

Monitoring the Hardware

Monitoring the InfiniBand Fabric

Monitoring the Subnet Manager

Controlling the Hardware

Controlling the InfiniBand Fabric

Controlling the Subnet Manager

Servicing the Switch

Replaceable Components

Servicing Power Supplies

Servicing Fans

Servicing InfiniBand Cables

Servicing the Battery

Firmware Upgrades

Remote Management

Understanding Oracle ILOM on the Switch

Oracle ILOM Overview

Supported Features

Understanding Oracle ILOM Targets

Installing the Oracle ILOM Firmware

Firmware Delivery

Acquire the Oracle ILOM Firmware Version 1.1.3

Install the Oracle ILOM Firmware Version 1.1.3

Administering Oracle ILOM (CLI)

CLI Overview

Accessing Oracle ILOM From the CLI

Switching Between the Oracle ILOM Shell and the Linux Shell

Monitoring Oracle ILOM Targets (CLI)

Controlling Oracle ILOM Targets (CLI)

Upgrading the Switch Firmware Through Oracle ILOM (CLI)

Administering Oracle ILOM (Web)

Web Interface Overview

Access Oracle ILOM From the Web Interface

Monitoring Oracle ILOM Targets (Web)

Performing Daily Tasks (Web)

Display the Date (Web)

Display the Switch Status LEDs States (Web)

Display the Aggregate Sensors State (Web)

Display Power Supply Status (Web)

Display Board-Level Voltages (Web)

Display Internal Temperatures (Web)

Display Fan Status (Web)

Display the Oracle ILOM Sessions (Web)

Display the Oracle ILOM Event Log (Web)

Checking the Status of Services (Web)

Display the HTTP Service Status (Web)

Display the HTTPS Service Status (Web)

Display the SSL Certificates (Web)

Display the SNMP Service Status (Web)

Display the SNMP Service User Accounts (Web)

Display the SNMP Service Communities (Web)

Display the IPMI Service Status (Web)

Display the SMTP Client Status (Web)

Display the Network Time Protocol Servers (Web)

Verifying Other Aspects With Oracle ILOM (Web)

Display the Alert Properties (Web)

Display the Oracle ILOM User Accounts (Web)

Display the Remote Log Hosts (Web)

Display the Network Management Configuration (Web)

Display the CLI Session Timeout (Web)

Display System Component FRU ID (Web)

Display the Firmware Version (Web)

Display Identification Properties (Web)

Controlling Oracle ILOM Targets (Web)

Performing General Tasks on Oracle ILOM Targets (Web)

Set the Date and Time (Web)

Set the Time Zone (Web)

Enable the Locator LED (Web)

Disable the Locator LED (Web)

Clear the Oracle ILOM Event Log (Web)

Set the Remote Log Hosts (Web)

Configure the SMTP Client (Web)

Back Up the Configuration (Web)

Restore the Configuration (Web)

Create a Snapshot of the Switch State (Web)

Snapshot Dataset Information (Web)

Set the Network Management Parameters (Web)

Set the Identification Properties (Web)

Performing Oracle ILOM User Tasks (Web)

Add an Oracle ILOM User Account (Web)

Change an Oracle ILOM User's Password and or Role (Web)

Delete an Oracle ILOM User Account (Web)

Managing HTTP Services (Web)

Enable the HTTP Service (Web)

Disable the HTTP Service (Web)

Managing HTTPS Services (Web)

Enable the HTTPS Service (Web)

Install a Custom SSL Certificate (Web)

Remove the Custom SSL Certificate (Web)

Disable the HTTPS Service (Web)

Managing SNMP Services (Web)

Enable the SNMP Service (Web)

Configure the SNMP Service (Web)

Add SNMP Service User Accounts (Web)

Modify SNMP Service User Accounts (Web)

Delete SNMP Service User Accounts (Web)

Add SNMP Service Communities (Web)

Modify SNMP Service Communities (Web)

Delete SNMP Service Communities (Web)

Back Up SNMP Service MIBs (Web)

Disable the SNMP Service (Web)

Managing Other Aspects With Oracle ILOM (Web)

Enable Alerts to Send SNMP Traps (Web)

Enable Alerts to Send PETs (Web)

Enable Alerts to Send Email Alerts (Web)

Disable Alerts (Web)

Set the CLI Session Timeout (Web)

Upgrading the Switch Firmware Through Oracle ILOM (Web)

Upgrade the Switch Firmware (Web)

Using the Fabric Monitor

Access the Fabric Monitor

Fabric Monitor Features

Accessing the Rear Panel Diagram

Accessing Status Pane Information

Control Panel Function

Monitoring Parameters and Status

Administering Oracle ILOM (SNMP)

SNMP Overview

Understanding SNMP Commands

Monitoring Oracle ILOM Targets (SNMP)

Controlling Oracle ILOM Targets (SNMP)

Administering Hardware (IPMI)

ipmitool Overview

Display the Sensors' State (IPMI)

Display the Sensor Information (IPMI)

Display the System Event Log (IPMI)

Display FRU ID Information (IPMI)

Display Switch Status LED States (IPMI)

Enable the Locator LED (IPMI)

Disable the Locator LED (IPMI)

Understanding Oracle ILOM Commands

cd Command

create Command

delete Command

dump Command

exit Command (ILOM)

help Command (ILOM)

load Command

reset Command

set Command

show Command

version Command (ILOM)

Reference

Understanding Hardware Commands

Linux Shells for Hardware Commands

chassis_led Command

checkboot Command

checkguidfilesftree Command

checkpower Command

checktopomax Command

checkvoltages Command

connector Command

dcsport Command

disablecablelog Command

disablelinklog Command

disablesm Command

disableswitchport Command

enablecablelog Command

enablelinklog Command

enablesm Command

enableswitchport Command

env_test Command

exit Command (Hardware)

generatetopology Command

getfanspeed Command

getmaster Command

getnm2type Command

getportstatus Command

help Command (Hardware)

ibdevreset Command

listlinkup Command

managementreset Command

matchtopology Command

setcontrolledhandover Command

setloghost Command

setmsmlocationmonitor Command

setsmpriority Command

setsubnetprefix Command

showfruinfo Command

showpsufru Command

showsmlog Command

showtemps Command

showtopology Command

showunhealthy Command

smconfigtest Command

version Command (Hardware)

Understanding InfiniBand Commands

Linux Shells for InfiniBand Commands

ibaddr Command

ibcheckerrors Command

ibchecknet Command

ibchecknode Command

ibcheckport Command

ibcheckportstate Command

ibcheckportwidth Command

ibcheckstate Command

ibcheckwidth Command

ibclearcounters Command

ibclearerrors Command

ibdatacounters Command

ibdatacounts Command

ibdiagnet Command

ibdiagpath Command

ibhosts Command

ibnetdiscover Command

ibnetstatus Command

ibnodes Command

ibportstate Command

ibroute Command

ibrouters Command

ibstat Command

ibstatus Command

ibswitches Command

ibsysstat Command

ibtracert Command

perfquery Command

saquery Command

sminfo Command

smpdump Command

smpquery Command

Understanding SNMP MIB OIDs

OID Tables Overview

Understanding the SUN-DCS-MIB MIB OIDs

SUN-HW-TRAP-MIB MIB OIDs

Understanding the SUN-ILOM-CONTROL-MIB MIB OIDs

Understanding the SUN-PLATFORM-MIB MIB OIDs

Understanding the ENTITY-MIB MIB OIDs

Index

Upgrade the Switch Firmware (Web)


Note - If the switch firmware package is located on the host administering the management controller, then you wil perform a local file upload and have additional considerations.


  1. Acquire the firmware package.

    See Acquire the Switch Firmware Package (CLI).

  2. Open a SSH session and connect to the management controller by specifying the controller’s host name as configured with the DHCP server.

    For example:

    % ssh -l root nm2name
    root@nm2name’s password: password
    #

    where nm2name is the host name of the management controller. The name might be the word hostname. Initially, the password is changeme.

  3. If the Subnet Manager is running on the management controller, disable it with the disablesm command.
    # disablesm
    Stopping partitiond daemon.                                [  OK  ]
    Stopping IB Subnet Manager..                               [  OK  ]
    # 
  4. Verify that there is at least 80 MB available in the / filesystem.
    # df -m /
    Filesystem           1M-blocks      Used Available Use% Mounted on
    /dev/hda2                  471     287     161     65%     /
    #

    In this example, there are 161 MB available. If not enough space is available, you must delete or move files from the / filesystem.

  5. Verify that there is at least 120 MB available in the /tmp directory.
    # df -h /tmp
    Filesystem            Size  Used Avail Use% Mounted on
    tmpfs                 250M  240K 249M 1% /tmp
    #

    In this example, there are 249 MB available. If not enough space is available, you must delete files from the /tmp directory.

  6. If you will perform a local file upload, perform these steps.

    Otherwise, go to Step 7.

    1. Verify that there is at least 120 MB available in the /dev/shm directory.
      # df -h /dev/shm
      Filesystem            Size  Used Avail Use% Mounted on
      tmpfs                 250M   16K  250M   1% /dev/shm
      #

      In this example, there are 250 MB available. If not enough space is available, you must delete or move files from the /dev/shm directory.

    2. Verify the free memory available.
      # free -m
                       total       used       free     shared    buffers     cached
      Mem:           498        104        393          0         12         47
      -/+ buffers/cache:         45        453
      Swap:            0          0          0
      #

      In the Mem: row of the free column, there should be at least 240 MB free memory. In this example, there are 393 MB available. If not enough memory is available, you must exit non-essential applications that are running.

    3. Go to Step 8.
  7. Verify the free memory available.
    # free -m
                     total       used       free     shared    buffers     cached
    Mem:           498        104        393          0         12         47
    -/+ buffers/cache:         45        453
    Swap:            0          0          0
    #

    In the Mem: row of the free column, there should be at least 120 MB free memory. In this example, there are 393 MB available. If not enough memory is available, you must exit non-essential applications that are running.

  8. Access the Oracle ILOM web interface.

    See Access Oracle ILOM From the Web Interface.

  9. Click the Maintenance tab.
  10. Click the Firmware Upgrade subtab.

    The Firmware Upgrade window opens.

  11. Click Enter Upgrade Mode.

    A dialog box opens and asks you to confirm.

  12. Click OK.

    The Firmware Upgrade window changes to Upgrade mode and now accepts either a local file path and file name, or a URL and file name of the switch firmware package.

  13. Consider your next step:
    • If you are performing a local file upload, click Browse and locate the file.
    • If the switch firmware package is located remotely, click Specify URL and type the fully qualified URL for the package.

    Note - Clicking Specify URL also changes the button to Local File Upload. Clicking Local File Upload changes the button back to Specify URL.



    Note - For the specified URL, only the FTP or HTTP protocols are supported.


  14. Click Upload.

    Oracle ILOM transfers the switch firmware package to the management controller. Oracle ILOM verifies the package integrity and displays the current versions of the firmware and versions in the package.

  15. Click Start Upgrade.

    A dialog box opens and asks you to confirm.

  16. Click OK.

    The upgrade begins and the status of the upgrade is reported.

    When the upgrade process ends, a log and summary report are displayed.

  17. Click OK.

    A final status is displayed, the upgrade either:

    • Succeeded

    • Partially succeeded

    • Failed

  18. Click Home.

    The Versions window opens.

  19. Reboot the switch to enable the new firmware.

    See Switch Administration, restarting the entire switch.


    Note - The restart process takes between 4 to 5 minutes to complete. The Oracle ILOM stack requires at least 2 minutes to become operational after a reboot.


  20. If previously disabled, open a SSH session, connect to the management controller, and enable the Subnet Manager.
    % ssh -l root nm2name
    root@nm2name’s password: password
    # enablesm
    Starting IB Subnet Manager.                                [  OK  ]
    Starting partitiond daemon.                                [  OK  ]
    # exit
Related Information