Documentation, Support, and Training
Check Network Management Port Status LEDs
Check Power Supply Status LEDs
Understanding Routing Through the Switch
CXP Connectors and Link LEDs to Switch Chip Port Routes
Switch Chip Port to Switch Chip Port Routes
Switch Chip Port to CXP Connectors and Link LED Routes
Signal Route Through the Switch
Administrative Command Overview
Display Switch Environmental and Operational Data
Display Switch Firmware Versions
Locate a Switch Chip or Connector From the GUID
Display Switch Chip Boot Status
Display Switch Chip Port Status
Monitoring the InfiniBand Fabric
Identify All Switches in the Fabric
Identify All HCAs in the Fabric
Display the InfiniBand Fabric Topology
Display a Route Through the Fabric
Display the Link Status of a Node
Display Data Counters for a Node
Display Low-Level Detailed Information About a Port
Restart the Management Controller
Recover Ports After Switch Chip Reset
Change the Administrator Password
Controlling the InfiniBand Fabric
Perform Comprehensive Diagnostics for the Entire Fabric
Perform Comprehensive Diagnostics for a Route
Determine Changes to the InfiniBand Fabric Topology
Find 1x or SDR or DDR Links in the Fabric
Determine Which Links Are Experiencing Significant Errors
Controlling the Subnet Manager
Set the Subnet Manager Priority
Start the Subnet Manager With the opensmd Daemon
If intensive troubleshooting is necessary to resolve a problem, the smpquery command can provide very detailed information about a node.
On the management controller, type:
# smpquery switchinfo lid
where lid is the LID of the node.
For example, to see detailed information about a switch with LID 24, type:
# smpquery switchinfo 24 # Switch info: Lid 24 LinearFdbCap:....................49152 RandomFdbCap:....................0 McastFdbCap:.....................4096 LinearFdbTop:....................25 DefPort:.........................0 DefMcastPrimPort:................255 DefMcastNotPrimPort:.............255 LifeTime:........................18 StateChange:.....................0 LidsPerPort:.....................0 PartEnforceCap:..................32 InboundPartEnf:..................1 OutboundPartEnf:.................1 FilterRawInbound:................1 FilterRawOutbound:...............1 EnhancedPort0:...................0 #
Switch Reference, smpquery command