This appendix discusses the various specifications of the Sun Blade T6340 server module. Topics covered are:
If you need specifications for the modular system chassis, see the chassis documentation.
A.1 Physical Specifications
FIGURE A-1 Server Module Dimensions
TABLE A-1 Server Module Dimensions
Callout
|
Measurement in Inches (Measurement in Millimeters)
|
1
|
19.56 in. (496.82 mm)
|
2
|
1.75 in. (44.6 mm)
|
3
|
12.88 in. (327.15 mm)
|
The Sun Blade T6340 server module may weigh up to 19.8 lbs (9 kg), depending on internal configuration.
A.2 System Environmental Specifications
TABLE A-2 includes the environmental requirements that are specific to the Sun Blade T6340 server module.
TABLE A-2 Sun Blade T6340 Environmental Requirements
Condition
|
Requirement
|
Operating temperature
|
5˚C (41˚F) to 35˚C (95˚F) noncondensing
|
Nonoperating temperature
|
-40˚C (-40˚ F) to 65˚C (149˚ F)
|
Operating humidity
|
10% to 90% noncondensing (27˚C (80˚ F) max. wet bulb)
|
Nonoperating humidity
|
93% noncondensing (38˚ C (100˚ F) max. wet bulb)
|
Operating altitude
|
3048 meters (10,000’) at 35˚C (95˚ F)
|
Nonoperating altitude
|
12,000 meters (40,000’)
|
A.3 Motherboard Block Diagram
FIGURE A-2 Motherboard Block Diagram
Sun Blade T6340 Server Module Service Manual
|