Sun Blade T6340 Server Module
Service Manual
820-3902-12
Contents |
1. Sun Blade T6340 Server Module Product Description
1.1.1 Multicore Processor Information
1.2 Support for RAID Storage Configurations
1.2.1 Sun Blade RAID 5 Expansion Module
To Create a Simple Volume Using Just One HDD
1.2.2 Sun Blade RAID 0/1 G2 Expansion Module
1.4 Additional Service Related Information
2.1 Sun Blade T6340 Server Module Diagnostics Overview
2.2 Memory Configuration and Fault Handling
2.2.1.1 FB-DIMM Installation Rules
2.2.1.3 Troubleshooting Memory Faults
2.3.1 Front Panel LEDs and Buttons
2.4 Using ILOM for Diagnosis and Repair Verification
2.5 Using the ILOM Web Interface For Diagnostics
2.5.1 Displaying System Faults
2.5.1.1 Viewing Fault Status Using the ILOM Web Interface
2.5.1.2 Viewing Fault Status Using the ILOM CLI
2.5.2 Displaying the Environmental Status with the ILOM CLI
2.5.3 Displaying the Environmental Status and Sensor Readings with the ILOM Web Interface
2.5.4 Displaying FRU Information
2.5.4.1 Using the ILOM Web Interface to Display FRU Information
2.5.4.2 Using the CLI to Display FRU Information
2.6.1 Controlling How POST Runs
2.6.2 Changing POST Parameters
2.6.2.1 Using the Web Interface to Change POST Parameters
2.6.2.2 Using the CLI to Change POST Parameters
2.6.3 Interpreting POST Messages
2.6.4 Clearing POST Detected Faults
2.6.4.1 Clearing Faults With the Web Interface
2.6.4.2 Clearing Faults With the ILOM CLI
2.6.4.3 Clearing Faults Manually with ILOM
2.6.4.4 Clearing Hard Drive Faults
2.7 Using the Solaris Predictive Self-Healing Feature
2.7.1 Identifying Faults With the fmadm faulty and fmdump Commands
2.7.1.1 Using the fmadm faulty Command
2.7.1.2 Using the fmdump Command
2.7.2 Clearing PSH Detected Faults
2.7.3 Clearing the PSH Fault From the ILOM Logs
2.8 Collecting Information From Solaris OS Files and Commands
2.8.1 Checking the Message Buffer
2.8.2 Viewing the System Message Log Files
2.9 Managing Components With Automatic System Recovery Commands
2.9.1 Displaying System Components With the show /SYS Command
2.10 Exercising the System With SunVTS
2.10.1 Checking SunVTS Software Installation
2.10.2 Exercising the System Using SunVTS Software
2.11 Resetting the Password to the Factory Default
2.11.1 To Reset the Root Password to the Factory Default
3. Replacing Hot-Swappable and Hot-Pluggable Components
3.1.3 Replacing a Hard Drive or Installing a New Hard Drive
4. Replacing Cold-Swappable Components
4.1.2 Electrostatic Discharge Safety
4.1.2.1 Using an Antistatic Wrist Strap
4.1.2.2 Using an Antistatic Mat
4.2 Common Procedures for Parts Replacement
4.2.2 Shutting Down the System
4.2.3 Shutting Down the Server Module Using the ILOM Web Interface
4.2.4 Shutting Down the Server Module Using the ILOM CLI
4.2.5 Preparing to Remove the Server Module
4.3 Removing and Replacing DIMMs
4.4 Removing and Replacing the Service Processor
4.4.1 Removing the Service Processor
4.4.2 Replacing the Service Processor
4.5 Removing and Replacing the Service Processor Battery
4.5.1 Removing the Service Processor Battery
4.5.2 Replacing the Service Processor Battery
4.6 Replacing and Installing the Sun Blade RAID 5 Expansion Module
4.6.1 Removing the Sun Blade RAID 5 Expansion Module
4.6.2 Installing the Sun Blade RAID 5 Expansion Module
4.6.3 Installing and Removing the Sun Blade RAID 5 Expansion Module Battery Tray
Installing the Sun Blade RAID 5 Expansion Module Battery Tray
Removing the Sun Blade RAID 5 Expansion Module Battery Tray
4.6.4 Configuring the Sun Blade RAID 5 Expansion Module
4.7 Replacing the Sun Blade G2 RAID 0/1 Expansion Module
4.7.1 Removing the Sun Blade G2 RAID 0/1 Expansion Module
4.7.2 Installing the Sun Blade G2 RAID 0/1 Expansion Module
4.8 Removing and Replacing a Fabric ExpressModule (FEM)
4.8.1 Removing the Fabric ExpressModule (FEM)
4.8.2 Replacing a Fabric ExpressModule (FEM)
4.9 Replacing the Compact Flash Module
4.10 Finishing Component Replacement
4.10.2 Reinstalling the Server Module in the Chassis
A.2 System Environmental Specifications
B. Creating a Bootable Array With the Sun Blade RAID 5 Expansion Module
B.1 About Creating a Bootable Array on a SPARC System
B.2 Creating a Bootable Array Task Map
B.3 Modifying the Miniroot Directory On the Install Server
To Modify the Miniroot Directory
B.4 Modifying the Product Installation Directory on the Install Server
To Modify the Product Installation Directory
B.5 Building a Logical Drive on Which to Install the Solaris OS
To Create a Logical Drive Using a Network Install Server
To Create a Logical Drive Without a Network Install Server
To Label the Newly Created Logical Drive
To Delete a Logical Drive on the REM
C. Installing the Solaris OS and the Sun Blade RAID 5 Expansion Module Driver
C.1 Preparing to Install the Solaris OS
To Prepare to Install the Solaris OS
C.2 Installing the RAID 5 Expansion Module Driver With the Solaris OS
To Install the RAID 5 Expansion Module Driver With the Solaris OS
D. XVR-50 Graphics Accelerator
D.2.1 Obtaining Available Screen Resolutions
D.3 Sun OpenGL for Solaris Software
D.7 Checking Device Configuration
E.3 HD15 Video Output Connector
F. ALOM CMT Reference Information
F.1 Switching Between the System Console and ALOM CMT and ILOM Shells
F.1.1 Switching From the ALOM CMT Shell to the ILOM Shell
F.2 Service-Related ALOM CMT Commands
G.1 Creating an ALOM CMT Shell
G.1.1 Creating an ALOM CMT Compatibility Shell
G.1.2 Connecting to the Host Console With SSH
G.1.3 Switching Between the ALOM CMT Shell and the Host Console
G.1.4 Returning to the ILOM CLI
G.2 Switching Between the ILOM CLI and ALOM CMT Compatibility Shell
G.3 Switching Between the System Console and ILOM
G.4 Connecting to the Server Module Service Processor From the Chassis CMM Service Processor
Copyright © 2010, Oracle and/or its affiliates. All rights reserved.