JavaScript is required to for searching.
Skip Navigation Links
Exit Print View
Sun Fire X2270 M2 Server Product Documentation
PDF
search filter icon
search icon

Document Information

Preface

Related Books

About This Documentation (PDF and HTML)

Documentation Comments

Download Server System Tools and Drivers

Documents History

Hardware Installation and Product Notes

Hardware Installation

Sun Fire X2270 M2 Server Installation Guide

Installation Overview and Preparation

Installing the Server Into a Rack With Optional Slide Rails

Managing Your Server

Communicating With the ILOM and the System Console

Configuring the Factory--Installed Oracle Solaris 10 Operating System

Powering On and Powering Off the Server

Troubleshooting and Support

Product Notes

Sun Fire X2270 M2 Server Product Notes

Operating System Installation

Oracle Solaris Operating System

Planning the Oracle Solaris Operating System Installation

Installing Oracle Solaris 10 OS

Linux

Introduction to Linux Installation

Preliminary Tasks Before Installing an OS

Installing Oracle Enterprise Linux

Installing SUSE Linux Enterprise Server

Installing Red Hat Enterprise Linux

Booting From OS Distribution Media

Configuring a Linux Server to Support PXE Installation

Identifying Logical and Physical Network Interface Names for Linux OS Configuration

Oracle VM

Installing Oracle VM

Windows

Planning the Operating System Installation

Installing Windows Server 2008 Operating System

Post Installation

Incorporating Sun Fire Drivers Into a WIM Image

Configuring RAID Controller in the BIOS Setup Utility

ESX

Sun Fire X2270 M2 Server Installation Guide for ESX Software

Preparing to Install VMware ESX 4.0 and ESXi 4.0

Installing VMware ESX 4.0

Installing VMware ESXi 4.0

Booting Installation Media

Administration, Diagnostics, and Service

Administration Using ILOM

Overview of the ILOM Supplement

ILOM Feature Set

Communicating With the ILOM and the System Console

ILOM Platform Features for the Sun Fire X2270 M2 Server

Using ILOM to Monitor the Host

Updating Firmware

Diagnostics

Preface

Related Documentation

About This Documentation (PDF and HTML)

Typographic Conventions

Documentation Comments

Change History

Diagnostics Guide

Introduction to Diagnostic Tools

About Diagnostic Tools

Strategy for Diagnostics

Service Processor

Standalone Package-Based Diagnostics

Offline Operating System-Based Diagnostics

Online Operating System-Based Diagnostics

Diagnostic Tools for Oracle Servers

BIOS/POST

U-Boot

Pc-Check

SunVTS

Snapshot Utility

Using the Diagnostic Tools to Troubleshoot a Server

Troubleshooting Scenarios

Diagnostic Test Coverage

Setting Up a Server for Testing

U-Boot Diagnostic Startup Tests

U-Boot Diagnostic Startup Tests Overview

System Diagnostic Test Options at Startup

U-Boot Diagnostic Test Modes-Normal, Quick, and Extended

Reporting Diagnostic Failures at System Startup

Running the U-Boot Diagnostic Tests

How to Select a U-Boot Diagnostic Mode to Run at Startup

Sample U-Boot Test Output

U-Boot Normal Mode- Test Output Sample

U-Boot Quick Mode- Test Output Sample

U-Boot Extended Mode- Test Output Sample

Sample SP Environmental Variables Showing U-Boot Test Status

Pc-Check Diagnostics Utility

Pc-Check Diagnostics Overview

Accessing Pc-Check Diagnostics Utility

How to Access Pc-Check Through the ILOM Web Interface

How to Access Pc-Check Through the ILOM CLI

System Information Menu

System Information Menu Options

Advanced Diagnostics Tests

Advanced Diagnostics Tests Menu Options

How to Test the Server's Hard Disks

Immediate Burn-In Testing

Full System Tests

Component Tests

How to Run Immediate Burn-in Tests

Deferred Burn-In Testing

How to Create and Save Scripts for Deferred Burn-in Testing

Create Diagnostic Partition

Create Diagnostic Partition Menu Option

Show Results Summary

Show Results Summary Menu Options

Print Results Report

About Pc-Check

Exit to DOS

Accessing the Pc-Check Diagnostics Utility on the Tools and Drivers CD/DVD

How to Access and Run Pc-Check From the Tools and Drivers CD/DVD

How to Access and Run Pc-Check From a USB Device

How to Set Up the Tools and Drivers CD/DVD Image on the PXE Server

How to Access the Tools and Drivers CD/DVD From the Target Server

Service

Sun Fire X2270 M2 Server Service Manual Organization

Sun Fire X2270 M2 Server Overview

Maintaining the Sun Fire X2270 M2 Server

Sun Fire X2270 M2 Server Service Procedures and Information

Sun Fire X2270 M2 Server Specifications

Index

U-Boot Extended Mode– Test Output Sample

This example is a sample output of a U-Boot test after it ran in -Extended mode.

Example 3 U-Boot Extended Mode-Test Output Sample

U-Boot 1.1.4

Custom AST2100 U-Boot 2.0 (Jan 26 2009 - 10:29:26) r41480

DRAM:  119 MB
Flash bank 0 at 10000000 has 0x2000000 bytes in 256 sectors
(chipSize 1<<25, size_ratio 1).Flash: 32 MB

readonly: ethaddr=00:14:4F:CA:B5:10
readonly: eth1addr=00:14:4F:CA:B5:11

VUART1 already enabled at port 0x03f8, SerIRQ[4] rise

Protecting U-Boot flash sectors; monitor_base=100a0000.

Negating BIOS_TOP_BLOCK_LOCK signal.

H/W: <product_name> Service Processor; SOC: AST2100 Rev. 02 (’A3’)
  PWC_SP_Broken_OD = 0;  ARM restart caused by: watch-dog ExtRst# pin
  The host is OFF(S5) (hostWantsPwr=0, powerGood=0,
  allowPwrOn=0|0, outOfReset=0, fatalError=0).
  Reset straps=0x88819180, def. H-PLL=264 MHz, CPU/AHB=2:1, boot CS0# normal speed
  PCI w/VGA noVBIOS;  DRAM clock is M-PLL: 264 MHz (DDR2-528)
  DRAM: 128MB data - 8MB VGA, 32-bit noECC, 2 BA 10 CA, CL=4 BL=4 ap=1, 61440 us refr

Board Revision - cc
               
Net:   faradaynic#0, faradaynic#1
Enter Diagnostics Mode [’q’uick/’n’ormal(default)/e’x’tended(manufacturing mode)]..... 0

Diagnostics Mode - EXTENDED(Manufacturing Mode)
               
<DIAGS> Memory Data Bus Test ... PASSED
<DIAGS> Memory Address Bus Test ... PASSED
<DIAGS> Testing 0MB to 24MB (TEXT_BASE - 7 MB) ... PASSED
<DIAGS> Testing 32MB (TEXT_BASE + 1MB) to 128MB ... PASSED
<DIAGS> Flash ID Test - Flash Bank 1 ... PASSED
<DIAGS> Testing Watchdog ... PASSED

I2C Probe Test - Motherboard
               
Bus     Device     Address     Results
============================================

1     Temp. Sensor(LM75) (U3006)             0x90      PASSED
2     Sys FRUID (U3003)             0xA0     PASSED
2     Power CPLD (U3301)              0x4E      PASSED
2     CPU0 Fault LED’s (U3001)             0x40     PASSED
2     CPU1 Fault LED’s (U3002)              0x42     PASSED
2     PCA9555 (Misc) (U3005)             0x44     PASSED
2     DIMM IMAX (U3102)              0x12      PASSED
6     Bank Panel Led’s (U2701)             0xC6 PASSED
6     DS1338(RTC) ( U803)             0xD0     PASSED

I2C Probe Test - Chassis (2U)

Bus     Device     Address     Results
============================================
PDB Board

1     PCA9548 Mux (U0202)             0xE0      PASSED
1     PDB FRUID (U0203)             0xAA      PASSED
1     MAX7313 (U0201)             0x40     PASSED

Power Supply 0

Bus     Device     Address     Results
============================================

1     0      PS 0 FRUID   ( - )          0xAC     PASSED
1     0      PS 0 CTRL    ( - )          0x7C      PASSED

Power Supply 1

Bus     Device     Address     Results
============================================

1     1      PS 1 FRUID   ( - )         0xAC      PASSED
1     1      PS 1 CTRL    ( - )         0x7C      PASSED

Fan Module  1

Bus     Device     Address     Results
============================================

1     2      FM 1 FRUID   (U0203)              0xAC      PASSED
1     2      FM 1 PCA9555 (U0201)             0x42      PASSED
1     2      FM 1 ADT7462 (U0202)             0xB8      PASSED

Fan Module  0

Bus     Device     Address     Results
============================================

1     3      FM 0 FRUID   (U0203)              0xAC      PASSED
1     3      FM 0 PCA9555 (U0201)              0x42      PASSED
1     3      FM 0 ADT7462 (U0202)              0xB8     PASSED

16 Disk Backplane

Bus     Device     Address     Results
============================================

1      4      BP MAX7313 (U1801) 0x44      PASSED
1      4      BP FRUID (U2102)          0xAC      PASSED
Paddle Card
Bus     Device     Address     Results
============================================

1      4      EXP FRUID (U0401)             0xAE      PASSED

<DIAGS> PHY #0 R/W Test ... PASSED
<DIAGS> PHY #0 Link Status ... PASSED
<DIAGS> ETHERNET PHY #0, Internal Loopback Test ... PASSED
<DIAGS>Testing RTC ... PASSED
<DIAGS> USB 1.1 Register Test ... PASSED
<DIAGS> USB2.0 Register Test ... PASSED
<DIAGS> USB 1.1 Test ... PASSED
<DIAGS>Access to BIOS Flash ... PASSED

CPU0 D0 ... Not Present
CPU0 D1 ... Not Present
CPU0 D2 ... Present

DIAGS>Verifying DIMM SPD Checksum on CPU0 D2 ... PASSED
SDRAM DEVICE                  DDR3 SDRAM
SDRAM SIZE                   2 GB
NUMBER OF ROWS & COLUMNS                   14 Row x 11 Column
CYCLE TIME                  DDR3 533Mhz clock(1066data rate)
MANUFACTURER_JEDEC_ID_CODE                   Micron
MANUFACTURED DATE                   Week 18 of ’08
MODULE SERIAL NUMBER                  EA09445A
MODULE_PART_NUMBER                   18JSF25672PY-1G1D

CPU0 D3 ... Not Present
CPU0 D4 ... Not Present
CPU0 D5 ... Not Present
CPU0 D6 ... Not Present
CPU0 D7 ... Not Present
CPU0 D8 ... Not Present
CPU1 D0 ... Not Present
CPU1 D1 ... Not Present
CPU1 D2 ... Present
               
<DIAGS>Verifying DIMM SPD Checksum on CPU1 D2 ... PASSED
SDRAM DEVICE                  DDR3 SDRAM
MODULE TYPE                  RDIMM
SDRAM SIZE                  2 GB
NUMBER OF ROWS & COLUMNS                   14 Row x 11 Column
CYCLE TIME                  DDR3 533Mhz clock(1066data rate)
MANUFACTURER_JEDEC_ID_CODE              Micron
MANUFACTURED DATE                   Week 18 of ’08
MODULE SERIAL NUMBER                   EA09445B
MODULE_PART_NUMBER                   18JSF25672PY-1G1D

CPU1 D3 ... Not Present
CPU1 D4 ... Not Present
CPU1 D5 ... Not Present
CPU1 D6 ... Not Present
CPU1 D7 ... Not Present
CPU1 D8 ... Not Present

<DIAGS> Testing PowerCPLD version ... PASSED
Booting linux in 3 seconds...