JavaScript is required to for searching.
Skip Navigation Links
Exit Print View
Sun Netra 6000 Modular System HTML Document Collection
search filter icon
search icon

Document Information

Using This Documentation

Product Notes

Related Documentation

Feedback

Access to Oracle Support

Installation

Preparing Your Site Before the System Arrives

Modular System Overview

Supported Racks

Location Restrictions for DC Models

Aisle Clearance for Service

AC Power Requirements

Determining DC Power Requirements

Environmental Requirements

Airflow Requirements

Acoustic Noise Emissions

Weight and Size Specifications for Moving and Lifting

Preparing to Install the Modular System

Gather Required Tools and Equipment

Remove the Shipping Carton

Verify Shipment Contents

Note the CMM MAC Address

Installing the Chassis Into Your Rack

Depopulating the Chassis

Mounting the Chassis in a Rack

Repopulating the Chassis

Connecting To and Powering On the Modular System

Role of Oracle ILOM During Installation

Connectivity Choices

CMM IP Address Configuration

Connecting Data and Management Cables

Powering On the Modular System

Log Into the CMM Through the SER MGT Port

Configure the CMM NET MGT Port With a Static IP Address

Configure the IP Addresses Using Your DHCP Server

Identify the IP and MAC Addresses

Log Into the CMM Through the NET MGT Port

Change the CMM ILOM root Account Password

Installing Shipping Brackets on a Sun Rack 1000

Install Shipping Brackets

Remove Shipping Brackets

Remote Management (ILOM)

Understanding Oracle ILOM on the Modular System

Oracle ILOM Overview

Oracle ILOM 3.0 Features Specific to the Modular System

Configuring CMM ILOM

Logging Into and Out of CMM ILOM

Performing Common CMM ILOM Configuration Tasks

Viewing and Configuring IP and MAC Addresses

Managing the CMM Clock

Administering the Modular System (CMM ILOM)

Managing the Chassis Using the CLI

Accessing Server Modules (CMM ILOM)

Interpreting Sensors

Sensor Overview

Display Sensor Readings (CLI)

Chassis Sensors

Fan Sensors

Power Supply Sensors

NEM Sensors

Server Module Sensors

Identifying SNMP Trap and PET Event Messages

SNMP Traps

PET Event Messages

Service

Monitoring Faults

Understanding Fault Management

Monitoring Faults (LEDs)

Monitoring Faults (Oracle ILOM)

Preparing for Service

Component Types and Service Classifications

Differences Between Chassis Models and Their Replacement Components

Determine if a Chassis Is A90-B or A90-D (CLI)

Determine if a Chassis Is A90-B or A90-D (Web Interface)

Gather Required Tools

Prevent ESD Damage

Power Off the Server Modules and Storage Modules

Power Off Components in the Chassis

Removing Power From the Chassis

Removing the Chassis From the Rack

Replacing CRUs

Replacing a Power Supply

Replacing a Front Fan Module (AC)

Replacing a Server or Storage Module

Replacing the FIM

Replacing a PCI EM

Replacing a NEM

Replacing a Rear Fan Module

Replacing the Fan Board

Replacing the CMM

Replacing FRUs

Replacing the Midplane

Replacing an Internal Power Cable (AC)

Replacing the DC Input Unit

Replacing a DC Adapter Tray

Returning the Modular System to Operation

Reinstalling the Chassis Into a Rack

Applying Power to the Chassis

Verify Modular System Functionality

Glossary

Index

PET Event Messages

PET events are generated by systems with ASF or an IPMI baseboard management controller. The PET events provide advance warning of possible system failures.

SNMP Event
SNMP Trap Sent
Sensor Name
Severity
Description
Temperature Upper critical threshold has been exceeded
petTrapTemperatureUpperNonCriticalGoingHigh
/CH/T_AMB

/CH/PSx/T_AMB

Major
Temperature has increased above upper critical threshold.
Temperature Upper critical threshold no longer exceeded
petTrapTemperatureUpperNonCriticalGoingLowDeassert
/CH/T_AMB

/CH/PSx/T_AMB

Warning
Temperature has decreased below upper critical threshold.
Temperature Lower fatal threshold has been exceeded
petTrapTemperatureUpperNonRecoverableGoingHigh
/CH/T_AMB

/CH/PSx/T_AMB

Critical
Temperature has increased above upper nonrecoverable threshold.
Temperature Lower fatal threshold no longer exceeded
petTrapTemperatureUpperNonRecoverableGoingLowDeassert
/CH/T_AMB

/CH/PSx/T_AMB

Major
Temperature has decreased below upper nonrecoverable threshold.
Temperature sensor ASSERT
petTrapTemperatureStateAssertedAssert
/CH/HOT
Critical
Temperature event occured. Possible cause: CPU is too hot.
Temperature sensor DEASSERT
petTrapTemperatureStateDeassertedAssert
/CH/HOT
Informational
Temperature event occured.
Entity Presence Insert
petTrapEntityPresenceDeviceInsertedAssert
/CH/BLx/PRSNT

/CH/BLx/HDDx/PRSNT

/CH/BLx/FMODx/PRSNT

/CH/BLx/ESM/PRSNT

/CH/NEMx/PRSNT

/CH/PSx/PRSNT

Informational
A device is present or has been inserted.
Entity Presence Remove
petTrapEntityPresenceDeviceRemovedAssert
/CH/BLx/PRSNT

/CH/BLx/HDDx/PRSNT

/CH/BLx/FMODx/PRSNT

/CH/BLx/ESM/PRSNT

/CH/NEMx/PRSNT

/CH/PSx/PRSNT

Informational
A device is absent or has been removed.
Module Transition to Running assert
petTrapModuleBoardTransitionToRunningAssert
/CH/BLx/STATE

/CH/NEMx/STATE

Informational
A device has transitioned to the normal running state. For a blade, this indicates that the host has powered on.
Module Transition to In Test assert
petTrapModuleBoardTransitionToInTestAssert
/CH/BLx/STATE

/CH/NEMx/STATE

Informational
A device is in a transitional state. (Only used for NEMs.)
Module Transition to Power Off assert
petTrapModuleBoardTransitionToPowerOffAssert
/CH/BLx/STATE

/CH/NEMx/STATE

Informational
A device has powered off.
Module Transition to On Line assert
petTrapModuleBoardTransitionToOnLineAssert
/CH/BLx/STATE

/CH/NEMx/STATE

Informational
A device is online and ready to enter the running state. (Only used for NEMs.)
Module Transition to Off Line assert
petTrapModuleBoardTransitionToOffLineAssert
/CH/BLx/STATE

/CH/NEMx/STATE

Informational
Unused.
Module Transition to Off Duty assert
petTrapModuleBoardTransitionToOffDutyAssert
/CH/BLx/STATE

/CH/NEMx/STATE

Informational
A device is no longer in use and is ready to be removed.
Module Transition to Degraded assert
petTrapModuleBoardTransitionToDegradedAssert
/CH/BLx/STATE

/CH/NEMx/STATE

Informational
A device has entered a state of degraded operation, for example, due to a hardware fault or an overtemperature condition that caused the device to shut itself down.
Module Transition to Power Save assert
petTrapModuleBoardTransitionToPowerSaveAssert
/CH/BLx/STATE

/CH/NEMx/STATE

Informational
Unused.
Module Install Error assert
petTrapModuleBoardInstallErrorAssert
/CH/BLx/STATE

/CH/NEMx/STATE

Informational
Unused.
OEM Reserved reporting Predictive Failure
petTrapOEMPredictiveFailureAsserted

12583937 QUESTION This number was in the C10 doc. Was it supposed to be there?

/CH/BLx/ERR

/CH/BLx/ESM/ERR

/CH/NEMx/ERR

Major
OEM predictive failure asserted.
OEM Reserved Return to normal
petTrapOEMPredictiveFailureDeasserted
/CH/BLx/ERR

/CH/BLx/ESM/ERR

/CH/NEMx/ERR

Informational
OEM predictive failure deasserted.
Fan reporting Predictive Failure
petTrapFanPredictiveFailureAsserted
/CH/FMx/ERR

/CH/PSx/FAN_ERR

Major
Fan Predictive Failure detected.
Fan Return to normal
petTrapFanPredictiveFailureDeasserted
/CH/FMx/ERR

/CH/PSx/FAN_ERR

Informational
Fan Predictive Failure state has been cleared.
Voltage reporting Predictive Failure
petTrapVoltagePredictiveFailureAssertedAssert
/CH/PSx/V_3V3_ERR

/CH/PSx/Sx/V_IN_ERR

/CH/PSx/Sx/V_12V_ERR

Major
Voltage Predictive Failure detected.
Voltage Return to normal
petTrapVoltagePredictiveFailureDeassertedAssert
/CH/PSx/V_3V3_ERR

/CH/PSx/Sx/V_IN_ERR

/CH/PSx/Sx/V_12V_ERR

Informational
Predictive failure state due to voltage event has been cleared.
Temperature reporting Predictive Failure
petTrapTemperaturePredictiveFailureAsserted
/CH/PSx/TEMP_WRN

/CH/PSx/TEMP_ERR

Major
System is reporting a predictive failure as a result of high temperature.
Temperature Return to normal
petTrapTemperaturePredictiveFailureDeasserted
/CH/PSx/TEMP_WRN

/CH/PSx/TEMP_ERR

Informational
Predictive failure state due to high temperature has been cleared.
Fan Lower fatal threshold has been exceeded
petTrapFanLowerNonREcoverableGoingLow
/CH/PSx/FANx/TACH
Critical
Fan speed has decreased below lower nonrecoverable threshold. Fan failed or removed.
Fan Lower fatal threshold no longer exceeded
petTrapFanLowerNonRecoverableGoingHighDeassert
/CH/PSx/FANx/TACH
Major
Fan speed has increased above lower nonrecoverable threshold.
Voltage sensor ASSERT
petTrapVoltageStateAssertedAssert
/CH/PSx/Sx/V_OUT_OK
Informational
Voltage event occured.
Voltage sensor DEASSERT
petTrapVoltageStateDeassertedAssert
/CH/PSx/Sx/V_OUT_OK
Informational
Voltage event occured.
Current reporting Predictive Failure
petTrapCurrentPredictiveFailureAsserted
/CH/PSx/Sx/I_12V_ERR

/CH/PSx/Sx/I_12V_WRN

Major
Predictive Failure due to electric current conditions.
Current Return to normal
petTrapCUrrentPredictiveFailureDeasserted
/CH/PSx/Sx/I_12V_ERR

/CH/PSx/Sx/I_12V_WRN

Informational
Predictive failure caused by electric current conditions.