Overview of the ILOM Supplement

Introduction to Oracle ILOM

Standard ILOM Features

Dual-Node Identification In CMM ILOM

Proving Physical Presence

Power Management

Clearing Server and CMM Faults

ILOM Preboot Menu

Managing Power Usage and Monitoring Power Consumption

Power Management Terminology

How to View Power Management Properties Using the Web Interface

How to View Power Management Properties Using the CLI

Configuring the Server Power Restore Policy

How to Set the Server Power Restore Policy Using the ILOM Web Interface

How to Set the Server Power Restore Policy Using the ILOM CLI

Switching the Default Serial Port Output Between SP and Host Console

How to Switch Default Serial Port Output Using the ILOM Web Interface

How to Switch Default Serial Port Output Using the ILOM CLI

Updating Firmware

Firmware Version Conventions

Determining Current Firmware Versions

How to Download Firmware Updates

Using ILOM to Update System BIOS and ILOM Firmware

Alternate Methods for Updating the System BIOS and ILOM Firmware

Resetting the Service Processor After an Update

Clearing CMOS Settings After an Update (Optional)

Using the ILOM Preboot Menu

Accessing the Preboot Menu

Preboot Menu Command Summary

Using the edit Command and Configuring the Preboot Menu For Remote Access

Resetting the Root Password to the Factory Default

Restoring ILOM Access to the Serial Console

Recovering the SP Firmware Image

Indicators, Sensors, and Traps

Indicators

Temperature and Power Sensors

Chassis Fan Failure Sensors

Chassis Fan Speed Sensors

Entity Presence Sensors

NEM and Blade Presence Sensors

Voltage Sensors

SNMP Traps

PET Event Messages

Index

SNMP Traps

SNMP traps are generated by SNMP agents that are enabled on the SNMP devices being managed by ILOM. ILOM receives the SNMP traps and converts them into SNMP event messages that appear in the event log.

The MIBs are available on the tools and drivers CD and can be downloaded from http://www.oracle.com/goto/blades.

The following tables list SNMP traps for each sensor.

Memory Events
SNMP Trap Message
ILOM Event Message
Description
Sensor Name
sunHwTrapMemoryFault
fault.memory.channel. misconfigured
Major; A memory component is suspected of causing a fault
/SYS/MB/P/D
sunHwTrapMemoryFault Cleared
fault.memory.channel. misconfigured
Informational; A memory component fault has been cleared
/SYS/MB/P/D
sunHwTrapComponentFault
fault.memory.intel.dimm.none

fault.memory.conroller. inputinvalid

fault.memory.controller. initfailed

fault.memory.intel.dimm. population-invalid

Major; A memory component is suspected of causing a fault
/SYS/MB
sunHwTrapComponentFault Cleared
fault.memory.intel.dimm.none

fault.memory.conroller. inputinvalid

fault.memory.controller. initfailed

fault.memory.intel.dimm. population-invalid

Informational; A memory component fault has been cleared
/SYS/MB
sunHwTrapMemoryFault
fault.memory.intel.dimm. incompatible

fault.memory.intel.dimm. incompatible-maxranks

fault.memory.intel.dimm. incompatible-quadrank

Major; A memory component is suspected of causing a fault
/SYS/MB/P/D
sunHwTrapMemoryFault Cleared
fault.memory.intel.dimm. incompatible

fault.memory.intel.dimm. incompatible-maxranks

fault.memory.intel.dimm. incompatible-quadrank

Informational; A memory component fault has been cleared
/SYS/MB/P/D
Environmental Events
SNMP Trap Message
ILOM Event Message
Description
Sensor Name
sunHwTrapPowerSupplyFault
fault.chassis.env.power.loss
Major; A power supply component is suspected of causing a fault
/SYS/MB/PS
sunHwTrapPowerSupplyFault Cleared
fault.chassis.env.power.loss
Informational; A power supply component fault has been cleared
/SYS/MB/PS
sunHwTrapComponentFault
fault.chassis.env.temp.over-fail
Major; A component is suspected of causing a fault
/SYS/
sunHwTrapComponentFault Cleared
fault.chassis.env.temp.over-fail
Informational; A component fault has been cleared
/SYS/
sunHwTrapTempCritThreshold Exceeded
Lower critical threshold exceeded
Major; A temperature sensor has reported that its value has gone above an upper critical threshold setting or below a lower critical threshold setting
/SYS/MB/T_AMB_FRONT

/SYS/MB/T_AMB_REAR

sunHwTrapTempCritThreshold Deasserted
Lower critical threshold no longer exceeded
Informational; A temperature sensor has reported that its value is in the normal operating range
/SYS/MB/T_AMB_FRONT

/SYS/MB/T_AMB_REAR

sunHwTrapTempNonCrit ThresholdExceeded
Upper noncritical threshold exceeded
Minor; A temperature sensor has reported that its value has gone above an upper critical threshold setting or below a lower critical threshold setting
/SYS/MB/T_AMB_FRONT

/SYS/MB/T_AMB_REAR

sunHwTrapTempOk
Upper noncritical threshold no longer exceeded
Informational; A temperature sensor has reported that its value is in the normal operating range
/SYS/MB/T_AMB_FRONT

/SYS/MB/T_AMB_REAR

sunHwTrapTempFatal ThresholdExceeded
Lower fatal threshold exceeded
Critical; A temperature sensor has reported that its value has gone above an upper fatal threshold setting or below a lower fatal threshold setting
/SYS/MB/T_AMB_FRONT

/SYS/MB/T_AMB_REAR

sunHwTrapTempFatal ThresholdDeasserted
Lower fatal threshold no longer exceeded
Informational; A temperature sensor has reported that its value has gone below an upper fatal threshold setting or above a lower fatal threshold setting
/SYS/MB/T_AMB_FRONT

/SYS/MB/T_AMB_REAR

sunHwTrapTempFatal ThresholdExceeded
Upper fatal threshold exceeded
Critical; A temperature sensor has reported that its value has gone above an upper fatal threshold setting or below a lower fatal threshold setting
/SYS/T_AMB
sunHwTrapTempCritThreshold Exceeded
Upper critical threshold exceeded
Major; A temperature sensor has reported that its value has gone above an upper critical threshold setting or below a lower critical threshold setting
/SYS/T_AMB
sunHwTrapTempCritThreshold Deasserted
Upper critical threshold no longer exceeded
Informational; A temperature sensor has reported that its value is in the normal operating range
/SYS/T_AMB
sunHwTrapTempFatal ThresholdDeasserted
Upper fatal threshold no longer exceeded
Informational; A temperature sensor has reported that its value has gone below an upper fatal threshold setting or above a lower fatal threshold setting
/SYS/T_AMB
sunHwTrapComponentError
Assert
Major; A power supply sensor has detected an error
/SYS/HOT

/SYS/PSn/Sn/V_ OUT_OK

sunHwTrapComponentOk
Deassert
Informational; A power supply sensor has returned to its normal state
/SYS/HOT

/SYS/PSn/Sn/V_ OUT_OK

Device Events
SNMP Trap Message
ILOM Event Message
Description
Sensor Name
sunHwTrapComponentFault
fault.chassis.device.missing
Major; A major component is suspected of causing a fault
/SYS/
sunHwTrapComponentFault Cleared
fault.chassis.device.missing
Informational; A component fault has been cleared
/SYS/
sunHwTrapComponentFault
fault.chassis.device.fail
Major; A component is suspected of causing a fault
/SYS/CMM
sunHwTrapComponentFault Cleared
fault.chassis.device.fail
Informational; A component fault has been cleared
/SYS/CMM
sunHwTrapIOFault
fault.chassis.device.fails
Major; A component in the IO subsystem is suspected of causing a fault
/SYS/NEM
sunHwTrapIOFault Cleared
fault.chassis.device.fails
Informational; An IO subsystem component fault has been cleared
/SYS/NEM
Power Supply Events
SNMP Trap Message
ILOM Event Message
Description
Sensor Name
sunHwTrapPowerSupplyError
Assert
Major; A power supply sensor has detected an error
/SYS/PWRBS
SunHwTrapPowerSupplyOk
Deassert
Informational; A power supply sensor has returned to its normal state
/SYS/PWRBS
sunHwTrapPowerSupplyFault
fault.chassis.env.power.loss
Major; A power supply component is suspected of causing a fault
/SYS/PS
sunHwTrapPowerSupplyFault Cleared
fault.chassis.env.power.loss
Informational; A power supply component fault has been cleared
/SYS/PS