JavaScript is required to for searching.
Skip Navigation Links
Exit Print View
Oracle Integrated Lights Out Manager (ILOM) 3.0

Supplement for Sun Server X2-4

search filter icon
search icon

Document Information

Using This Documentation

1.  Determining Your Server Management Strategy

Common Server Management Tasks

Server Management Software Benefits

Oracle Integrated Lights Out Manager

Oracle Hardware Management Pack

Oracle Hardware Installation Assistant

Evaluating Your Server Environment

Which Operating System Do You Plan to Install?

From Which Platform Do You Want to Run the Software?

Do You Want to Update or Monitor Your System Components?

Do You Have a Modular System Environment?

Server Management Downloads and Documentation

2.  Oracle ILOM 3.0 Documentation

Oracle ILOM 3.0 Documentation Collection

Oracle ILOM 3.0 Server-Specific Documentation

3.  Oracle ILOM Platform Features for the Sun Server X2-4

Supported Sun Server X2-4 Firmware

Power Management Policies

Host Power Throttling and Recovery

Service Processor Power-On Policy

Low Line AC Override Policy

Configure SP Power Management Policies Using the Web Interface

Configure SP Power Management Policies Using the CLI

Oracle ILOM Sideband Management

Special Considerations for Sideband Management

Configure Sideband Management Using the Web Interface

Configure Sideband Management Using the CLI

Configure Sideband Management Using the Host BIOS Setup Utility

Switch Serial Port Output Between SP and Host Console

Switch Serial Port Output Using the Web Interface

Switch Serial Port Output Using the CLI

Server Chassis Intrusion Sensor

How the /SYS/INTSW Sensor Works

Fault Management

Determining Faults

Clearing Faults

Components With No Fault Diagnosis

Viewing Sensors Using IPMItool

Sensors and Indicators Reference Information

System Components

System Indicators

Temperature Sensors

Power Supply Fault Sensors

Fan Speed and Physical Security Sensors

Power Supply Unit Current, Voltage, and Power Sensors

Entity Presence Sensors

SNMP and PET Message Reference Information

SNMP Traps

PET Event Messages

4.  Getting Server Firmware and Software

Firmware and Software Updates

Firmware and Software Access Options

Available Software Release Packages

Accessing Firmware and Software

Download Firmware and Software Using My Oracle Support

Requesting Physical Media

Gathering Information for the Physical Media Request

Request Physical Media (By Phone)

Installing Updates

Installing Firmware

Installing Hardware Drivers and OS Tools

Index

SNMP and PET Message Reference Information

This section describes Simple Network Management Protocol (SNMP) and Platform Event Trap (PET) messages that are generated by devices being monitored by Oracle ILOM.

SNMP Traps

SNMP Traps are generated by the SNMP agents that are installed on the SNMP devices being managed by Oracle ILOM. Oracle ILOM receives the SNMP Traps and converts them into SNMP event messages that appear in the event log. For more information about the SNMP event messages that might be generated on your system, see SNMP Traps and Corresponding Oracle ILOM Events for Sun Server X2-4  .

Table 3-9 SNMP Traps and Corresponding Oracle ILOM Events for Sun Server X2-4  

SNMP Trap Message
ILOM Event Message
Severity and Description
Sensor Name
Memory Events

sunHwTrapComponentFault
fault.memory.intel.boot-setup-init-failed
Major; A component is suspected of causing a fault
/SYS/
fault.memory.intel.boot-retries-failed
fault.memory.intel.dimm.none
/SYS/MB
fault.memory.controller.input-invalid
fault.memory.controller.init-failed
sunHwTrapComponentFault Cleared
fault.memory.intel.boot-setup-init-failed
Informational; A component fault has been cleared
/SYS/
fault.memory.intel.boot-retries-failed
fault.memory.intel.dimm.none
/SYS/MB
fault.memory.controller.input-invalid
fault.memory.controller.init-failed
Service Processor Events

sunHwTrapComponentFault
fault.chassis.device.misconfig
Major; A component is suspected of causing a fault
/SYS/SP
fault.sp.failed
sunHwTrapComponentFaultCleared
fault.chassis.device.misconfig
Informational; A component fault has been cleared
fault.sp.failed
Environmental Events

sunHwTrapComponentFault
fault.chassis.env.temp.over-fail
Major; A component is suspected of causing a fault
/SYS/
sunHwTrapComponentFaultCleared
fault.chassis.env.temp.over-fail
Informational; A component fault has been cleared
/SYS/
sunHwTrapTempCritThresholdExceeded
Lower critical threshold exceeded
Major; A temperature sensor has reported that its value has gone above an upper critical threshold setting or below a lower critical threshold setting
/SYS/MB/T_OUT

/SYS/DBP/T_AMB

Upper critical threshold exceeded
/SYS/MB/T_OUT

/SYS/T_AMB

/SYS/DBP/T_AMB

sunHwTrapTempCritThresholdDeasserted
Lower critical threshold no longer exceeded
Informational; A temperature sensor has reported that its value is in the normal operating range
/SYS/MB/T_OUT

/SYS/DBP/T_AMB

Upper critical threshold no longer exceeded
/SYS/MB/T_OUT

/SYS/T_AMB

/SYS/DBP/T_AMB

sunHwTrapTempNonCritThresholdExceeded
Upper noncritical threshold exceeded
Minor; A temperature sensor has reported that its value has gone above an upper critical threshold setting or below a lower critical threshold setting
/SYS/MB/T_OUT

/SYS/DBP/T_AMB

sunHwTrapTempOk
Upper noncritical threshold no longer exceeded
Informational; A temperature sensor has reported that its value is in the normal operating range
/SYS/MB/T_OUT

/SYS/DBP/T_AMB

sunHwTrapTempFatalThresholdExceeded
Lower fatal threshold exceeded
Critical; A temperature sensor has reported that its value has gone above an upper fatal threshold setting or below a lower fatal threshold setting
/SYS/MB/T_OUT

/SYS/DBP/T_AMB

Upper fatal threshold exceeded
/SYS/MB/T_OUT

/SYS/T_AMB

/SYS/DBP/T_AMB

sunHwTrapTempFatalThresholdDeasserted
Lower fatal threshold no longer exceeded
Informational; A temperature sensor has reported that its value has gone below an upper fatal threshold setting or above a lower fatal threshold setting
/SYS/MB/T_OUT

/SYS/DBP/T_AMB

Upper fatal threshold no longer exceeded
/SYS/MB/T_OUT

/SYS/T_AMB

/SYS/DBP/T_AMB

System Power Events

sunHwTrapComponentFault
fault.chassis.power.missing
Major; A component is suspected of causing a fault
/SYS/
fault.chassis.power.overcurrent
fault.chassis.power.inadequate
sunHwTrapComponentFaultCleared
fault.chassis.power.missing
Informational; A component fault has been cleared
/SYS/
fault.chassis.power.overcurrent
fault.chassis.power.inadequate
sunHwTrapPowerSupplyFault
fault.chassis.env.power.loss
Major; A power supply component is suspected of causing a fault
/SYS/PS
fault.chassis.power.ac-low-line
fault.chassis.device.wrong
sunHwTrapPowerSupplyFaultCleared
fault.chassis.env.power.loss
Informational; A power supply component fault has been cleared
/SYS/PS
fault.chassis.power.ac-low-line
fault.chassis.device.wrong
sunHwTrapPowerSupplyError
Assert
Major; A power supply sensor has detected an error
/SYS/PWRBS

/SYS/PSn/ V_IN_ERR

/SYS/PSn/ V_IN_WARN

/SYS/PSn/ V_OUT_ERR

/SYS/PSn/ I_OUT_ERR

/SYS/PSn/ I_OUT_WARN

/SYS/PSn/T_ERR

/SYS/PSn/ T_WARN

/SYS/PSn/ FAN_ERR

/SYS/PSn/ FAN_WARN

/SYS/PSn/ERR

Deassert
/SYS/PSn/ V_OUT_OK
sunHwTrapPowerSupplyOk
Deassert
Informational; A power supply sensor has returned to its normal state
/SYS/PWRBS

/SYS/PSn/ V_IN_ERR

/SYS/PSn/ V_IN_WARN

/SYS/PSn/ V_OUT_ERR

/SYS/PSn/ I_OUT_ERR

/SYS/PSn/ I_OUT_WARN

/SYS/PSn/T_ERR

/SYS/PSn/ T_WARN

/SYS/PSn/ FAN_ERR

/SYS/PSn/ FAN_WARN

/SYS/PSn/ERR

Assert
/SYS/PSn/ V_OUT_OK
sunHwTrapComponentError
ACPI_ON_WORKING ASSERT
Major; A sensor has detected an error
/SYS/ACPI
ACPI_ON_WORKING DEASSERT
ACPI_SOFT_OFF ASSERT
ACPI_SOFT_OFF DEASSERT
Entity Presence Events

UNKNOWN
ENTITY_PRESENT ASSERT
Informational
/SYS/MB/Pn/ PRSNT

/SYS/MB/Pn/MRn/PRSNT

/SYS/MB/PCIEn/PRSNT

/SYS/MB/ PCIE_CC/PRSNT

ENTITY_PRESENT DEASSERT
ENTITY_ABSENT ASSERT
ENTITY_ABSENT DEASSERT
ENTITY_DISABLED ASSERT
ENTITY_DISABLED DEASSERT
Fans, Hard Drives, and Physical Security Events

sunHwTrapComponentFault
fault.chassis.device.fan.column-fail
Major; A component is suspected of causing a fault
/SYS
fault.security.enclosure-open
sunHwTrapComponentFaultCleared
fault.chassis.device.fan.column-fail
Informational; A component fault has been cleared
/SYS/
fault.security.enclosure-open
UNKNOWN
Assert
Informational
/SYS/MB/PCIEn/WIDTH

/SYS/ESMR/ESM/FAULT

Deassert
sunHwTrapSecurityIntrusion
CHASSIS_INTRUSION ASSERT
Major; An intrusion sensor has detected that someone may have physically tampered with the system
/SYS/INTSW
CHASSIS_INTRUSION DEASSERT
sunHwTrapFanSpeedCritThresholdExceeded
Lower critical threshold exceeded
Major; A fan speed sensor has reported that its value has gone above an upper critical threshold setting or below a lower critical threshold setting
/SYS/FB/FANn/ TACH
sunHwTrapFanSpeedCritThresholdDeasserted
Lower critical threshold no longer exceeded
Informational; A fan speed sensor has reported that its value has gone below an upper critical threshold setting or above a lower critical threshold setting
sunHwTrapFanSpeedFatalThresholdExceeded
Lower fatal threshold exceeded
Critical; A fan speed sensor has reported that its value has gone above an upper fatal threshold setting or below a lower fatal threshold setting
sunHwTrapFanSpeedFatalThresholdDeasserted
Lower fatal threshold no longer exceeded
Informational; A fan speed sensor has reported that its value has gone below an upper fatal threshold setting or above a lower fatal threshold setting
System Chassis and I/O Events

sunHwTrapComponentFault
fault.chassis.boot.ipmi-init-failed
Major; A component is suspected of causing a fault
/SYS/
fault.io.quickpath.qpirc-init-failed
fault.io.quickpath.qpirc-failed
fault.io.quickpath.mrc-failed
sunHwTrapComponentFaultCleared
fault.chassis.boot.ipmi-init-failed
Informational; A component fault has been cleared
/SYS/
fault.io.quickpath.qpirc-init-failed
fault.io.quickpath.qpirc-failed
fault.io.quickpath.mrc-failed

PET Event Messages

Platform Event Trap (PET) event messages are generated by systems with Alert Standard Format (ASF) or an IPMI baseboard management controller. The PET events provide advance warning of possible system failures. For more information about the PET event messages that might occur on your system, see PET Messages and Corresponding Oracle ILOM Events for Sun Server X2-4  .

Table 3-10 PET Messages and Corresponding Oracle ILOM Events for Sun Server X2-4  

PET Message
ILOM Event Message
Severity and Description
Sensor Name
System Power Events

petTrapACPIPowerStateS5G2SoftOffAssert
SystemACPI 'ACPI_ON_WORKING'
Informational; System ACPI Power State S5/G2 (soft-off) was asserted
/SYS/ACPI
petTrapACPIPowerStateS5G2SoftOffDeassert
System ACPI Power State : ACPI : S5/G2: soft-off : Deasserted
Informational; System ACPI Power State S5/G2 (soft-off) was deasserted
petTrapACPIPowerStateS0G0WorkingAssert
System ACPI Power State : ACPI : S0/G0: working : Asserted
Informational; System ACPI Power State S0/G0 (working)
petTrapACPIPowerStateS0G0WorkingDeassert
System ACPI Power State : ACPI : S0/G0: working : Deasserted
Informational; System ACPI Power State S0/G0 (working) was deasserted
petTrapPowerSupplyStateAssertedAssert
PowerSupply sensor DEASSERT
Informational; Power Supply is connected to AC Power
/SYS/PSn/ V_OUT_OK

/SYS/PSn/ V_IN_ERR

/SYS/PSn/ V_IN_WARN

/SYS/PSn/ V_OUT_ERR

/SYS/PSn/ I_OUT_ERR

/SYS/PSn/ I_OUT_WARN

/SYS/PSn/T_ERR

/SYS/PSn/ T_WARN

/SYS/PSn/ FAN_ERR

/SYS/PSn/ FAN_WARN

/SYS/PSn/ERR

petTrapPowerSupplyStateDeassertedAssert
PowerSupply sensor ASSERT
Warning; Power Supply is disconnected from AC Power
Entity Presence Events

petTrapEntityPresenceEntityPresentAssert
Entity Presence : PCIE1/PRSNT : Present : Asserted
Informational; The Entity identified by the Entity ID is present
/SYS/PCIEn/ PRSNT

/SYS/PCIE_CC/ PRSNT

petTrapEntityPresenceEntityAbsentDeassert
Entity Presence : PCIE1/PRSNT : Absent : Deasserted
petTrapEntityPresenceEntityAbsentAssert
Entity Presence : PCIE1/PRSNT : Absent : Asserted
Informational; The Entity identified by the Entity ID is absent
petTrapEntityPresenceEntityPresentDeassert
Entity Presence : PCIE1/PRSNT : Present : Deasserted
Informational; The Entity identified by the Entity ID for the sensor is absent
petTrapEntityPresenceEntityDisabledAssert
Entity Presence : PCIE1/PRSNT : Disabled : Asserted
Informational; The Entity identified by the Entity ID is present, but has been disabled
/SYS/PCIE4/ PRSNT

/SYS/PCIE6/ PRSNT

/SYS/PCIE_CC/ PRSNT

petTrapEntityPresenceEntityDisabledDeassert
Entity Presence : PCIE1/PRSNT : Disabled : Deasserted
Informational; The Entity identified by the Entity ID is present and has been enabled
petTrapEntityPresenceDeviceInsertedAssert
Entity Presence : PS0/PRSNT : DevicePresent
Informational; A device is present or has been inserted
/SYS/PSn/PRSNT

/SYS/FB/FANn/ PRSNT

/SYS/DBP/HDDn/PRSNT

petTrapEntityPresenceDeviceRemovedAssert
Entity Presence : PS0/PRSNT : DeviceAbsent
Informational; A device is absent or has been removed
Environmental Events

petTrapTemperatureUpperNonRecoverableGoingLowDeassert
Temperature Upper non-critical threshold has been exceeded
Major; Temperature has decreased below upper non-recoverable threshold
/SYS/MB/T_OUT

/SYS/DBP/T_AMB

/SYS/T_AMB

petTrapTemperatureUpperCriticalGoingLowDeassert
Temperature Lower non-critical threshold has been exceeded
Warning; Temperature has decreased below upper critical threshold
petTrapTemperatureUpperNonRecoverableGoingHigh
Temperature Lower non-critical threshold no longer exceeded
Critical; Temperature has decreased below upper non-recoverable threshold
petTrapTemperatureUpperCriticalGoingHigh
Temperature Lower fatal threshold has been exceeded
Major; Temperature has increased above upper critical threshold
Fans, Hard Drives, and Physical Security Events

petTrapPhysicalSecurityChassisIntrusionStateDeassertedAssert
Physical Security : INTSW : State Deasserted
Informational; Physical security: chassis intrusion alarm cleared
/SYS/INTSW
petTrapPhysicalSecurityChassisIntrusionStateAssertedAssert
Physical Security : INTSW : State Asserted
Warning; Physical security breach: chassis intrusion
petTrapFanLowerCriticalGoingLow
Fan Lower fatal threshold has been exceeded
Major; Fan speed has decreased below lower critical threshold
/SYS/FB/FANn/ TACH
petTrapFanLowerCriticalGoingHighDeassert
Fan Lower fatal threshold no longer exceeded
Warning; Fan speed has increased above lower critical threshold
petTrapDriveSlotDriveFaultAssert
Drive Slot : DBP/HDD0/STATE : Drive Fault : Asserted
Critical; HDD Fault has been detected. A corresponding HDD Fault LED is ON
DBP/HDDn/ STATE
petTrapDriveSlotDriveFaultDeassert
Drive Slot : DBP/HDD0/STATE : Drive Fault : Deasserted
Informational; HDD Fault has been cleared. An HDD Fault LED which was ON is now OFF
petTrapDriveSlotPredictiveFailureAssert
Drive Slot : DBP/HDD0/STATE : Predictive Failure : Asserted
Major; HDD Predictive Failure has been detected
petTrapDriveSlotReadyToRemoveAssert
Drive Slot : DBP/HDD0/STATE : Hot Spare : Asserted
Informational: A drive has been unmounted and is ready to be physically removed. A corresponding OK-to-Remove LED is ON
petTrapDriveSlotReadyToRemoveDeassert
Drive Slot : DBP/HDD0/STATE : Hot Spare : Deasserted
Informational; A drive is no longer ready to be physically removed. It has either been removed or mounted again. A corresponding OK-to-Remove LED is OFF
petTrapDriveSlotPredictiveFailureDeassert
Drive Slot : DBP/HDD0/STATE : Predictive Failure : Deasserted
Informational; Hard Disk Predictive Failure state has been cleared