JavaScript is required to for searching.
Skip Navigation Links
Exit Print View
Sun Server X2-8 (formerly Sun Fire X4800 M2) Service Manual     Sun Server X2-8 (formerly Sun Fire X4800 M2) Documentation Library
PDF
search filter icon
search icon

Document Information

Using This Documentation

Sun Server X2-8 Name Change

Product Downloads

Documentation and Feedback

About This Documentation

Change History

Sun Server X2-8 Service Manual Overview

Server and Component Overview

Sun Server X2-8 Overview

Component Overviews

Front Panel Indicator Module Overview

Power Supply Overview

Hard Drive and XL Bracket Assembly Overview

Drive Backplane Overview

DIMM Overview

RAID Expansion Module Overview

Fabric Expansion Module Overview

System Battery Overview

CPU and Heatsink Assembly Overview

Internal USB Port Overview

Fan Module Overview

Network Express Module Overview

Service Processor (SP) Module Overview

SP Module Multiport Cable Overview

PCIe ExpressModule Overview

AC Power Block Overview

Fan Module Controller Board (FB) Overview

Midplane Overview

Component Removal and Installation Levers

Power and Reset

Power Modes

Power Button and Power OK LED

How to Power On the Server

How to Power Off the Server

Controlling Server Power Remotely

Removing and Installing Components

Preparing for Service and Operation

Removal and Installation Procedures

Removing and Installing a Power Supply (CRU)

Removing and Installing a Hard Drive (CRU)

Removing and Installing a Hard Drive Filler

Replacing the Hard Drive Backplane (FRU)

Adding, Removing, and Installing a CMOD (CRU)

CPU Module (CMOD) Designation and Population Rules

Removing and Installing a CMOD Filler

How to Replace the CMOD Battery (CRU)

Removing and Installing DIMMs (CRU)

DIMM Population Rules

Removing and Installing a RAID Expansion Module (CRU)

Removing and Installing a Fabric Expansion Module (CRU)

Replacing a CPU and Heatsink Assembly (FRU)

Removing and Installing a Fan Module (CRU)

Replacing a Fan Module Controller Board (FRU)

Removing and Installing a NEM or a NEM Filler (CRU)

Removing and Installing a PCIe EM (CRU)

Removing and Installing the Service Processor Module (CRU)

Removing and Installing the Multiport Cable

Removing and Installing the Subassembly Module (FRU)

Sun Server X2-8 Service Procedures and Information

Managing FRUID Information

Firmware Information and Procedures

How to Access the BIOS Setup Utility

BIOS Setup Utility Screens

Component LED Locations and Functions

Thermal Sensor Locations

Sun Server X2-8 Specifications

Physical Specifications

Power Specifications

Environmental Specifications

Requesting Physical Media

How to Request Physical Media Online

How To Request Physical Media by Phone

Index

AC Power Block Overview

image:An illustration showing the AC power block.
Legend
1
Retaining clip (4)
2
AC power inlet (4)

Each AC input connector supplies power to one of the power supply slots at the front of the machine. The input connectors are designated from left to right. The left-most connector is designated as 0 and supplies power to power supply slot 0 (the bottom slot at the front of the server). The right most connector is designated as 3 and supplies power to power supply slot 3 (the top slot at the front of the server). The following table shows the relationship between the power supply slots and AC input connectors.

Power slot (bottom to top)
PS 0
PS 1
PS 2
PS 3
AC input connector (left to right)
AC 0
AC 1
AC 2
AC 3

See also: