Slot Restrictions for Certain
Cards
Some optional I/O cards are restricted to specific I/O slots
to meet system cooling requirements. Other I/O cards provide better
performance when installed in particular slots. The below table
lists these slot requirements.
Note - This table lists only I/O cards that have specific slot
or quantity restrictions or other requirements. It does not list
I/O cards that are supported by the server but are not subject to
slot or quantity restrictions.
|
|
|
|
XAUI Cards |
|
|
|
10 GbE XFP XAUI adapter card |
SE3X7XA1Z |
2 |
Slots 0 and 1 only. Use slot 0
first, then slot 1. |
Network Interface
Cards |
|
|
|
Sun Quad Port GbE PCIe 2.0 Low Profile Adapter,
MMF |
7100481 |
4 |
|
Sun Quad Port GbE PCIe 2.0 Low Profile Adapter,
UTP |
7100477 |
4 |
Slots 0, 1, or 2 only. Required to meet NEBS level 3 compliancy.
|
Sun Dual Port 10GBase-T Adapter |
7100488 |
2 |
|
Sun x8 PCI-Express Quad Gigabit Ethernet Cards |
X4447A-Z-N |
2 |
|
Dual-Port 10 Gigabit-Ethernet PCIe 2.0 Copper/Fiber
SFP+ |
X1109A-Z |
2 |
|
Fibre Channel
Host Bus Adapters |
|
|
|
8Gb Dual-Port Fibre Channel PCI-Express, QLogic |
SG-XPCIE2FC-QF8-N |
3 |
|
8Gb Dual-Port Fibre Channel PCI-Express, Emulex |
SG-XPCIE2FC-EM8-N |
3 |
|
SAS Host Bus
Adapters PCI-E |
|
|
|
Sun Storage 6 Gb SAS PCIe RAID HBA, Internal |
SGX-SAS6-R-INT-Z |
1 |
Slot 0 only.
|
Sun Storage 6 Gb SAS PCIe HBA, External |
SGX-SAS6-EXT-Z |
2 |
|
|