Sun Storage 16 Gb Fibre Channel PCIe Host Bus Adapter, Emulex Installation Guide For HBA Model 7101684

Exit Print View

Updated: August 2018
 
 

Viewing LEDs

You can view green and yellow LEDs through openings in the mounting bracket of the HBA. Each port has a corresponding set of green and yellow LEDs. See Optical HBA LED Indicators. The green LED indicates firmware operation and the yellow LED indicates port activity or link speed.

This section describes how to interpret LED indicator combinations and power-on self test (POST) results. The section contains the following topics:

LED Indicator Combinations

Optical HBA LED Indicators shows the LED indicators on the HBA.

Figure 1  Optical HBA LED Indicators

image:Figure that depicts the HBA LED indicators.

Each port has a corresponding set of LEDs that provide a visual indication of the operating state.

Figure 6, Table 6, FC Mode LED Status  summarizes the LED indicator combinations, and their meanings, for the HBA. Refer to Optical HBA LED Indicators to determine the location of the LEDs.

Table 6  FC Mode LED Status 
Green LED
Yellow LED
State
Off
Off
Boot failure (Dead board)
Off
On
POST failure (Dead board)
Off
Slow Blink
Boot failure after POST
Off
Fast Blink
Not Defined
Off
Flashing
POST processing in progress
On
Off
Failure in Common Code Module
On
On
Failure in Common Code Module
On
1 Fast Blink
Normal (Link up at 2 GFC) (legacy compatibility only)
On
2 Fast Blinks
Normal (Link up at 4 GFC)
On
3 Fast Blinks
Normal (Link up at 8 GFC)
On
4 Fast Blinks
Normal (Link up at 16 GFC)
On
Flashing
Not defined
Slow Blink
Off
Normal link down
Slow Blink
On
Not defined
Slow Blink
Slow Blink
Not defined
Slow Blink
Fast Blink
Not defined
Slow Blink
Flashing
Not defined
Fast Blink
Off
Not defined
Fast Blink
On
Not defined
Fast Blink
Slow Blink
Not defined
Fast Blink
Fast Blink
Beaconing
Fast Blink
Flashing
Not defined

Note -  For the link rate conditions, there is a 1 second pause when the LED is off between each group of fast blinks (2, 3, or 4). Observe the LED sequence for several seconds to be sure you have correctly identified the pattern.

POST Results

Power-On Self Test ( POST) is the default mode of self-test for the Sun Storage 16 Gb FC PCIe HBA. No jumpers or connectors are necessary for this test to run. These tests perform a quick confidence level check of the HBA before running the operational software.

At a minimum, the following tests are performed by POST:

  • Flash boot image checksum test

  • Internal ASIC RAM tests for proper ECC and parity operation

  • NL Port loopback test