Oracle® Big Data Appliance Owner's Guide Release 1 (1.0.3) Part Number E25960-05 |
|
|
PDF · Mobi · ePub |
This appendix lists the replacement units for Oracle Big Data Appliance. All replacement units are FRUs (field replaceable units), which are installed by trained Oracle field engineers.
This appendix contains the following sections:
See Also:
Chapter 14 for information about the preinstallation and postinstallation stepsRepair categories describe the potential impact of a repair action. Table A-1 describes the categories, and actions.
Table A-1 Oracle Big Data Appliance Repair Categories
Category | Description | Scenario Examples |
---|---|---|
Hot Swap (HS) |
Repair part is hot swappable and can be replaced without shutting down the host system. Procedures may be needed before and after replacement to protect the data. |
|
Infrastructure Repair (IR) |
Repair of a connectivity component within an Oracle Big Data Appliance rack. No downtime of the rack is required, however, individual components may require downtime. |
|
BDA Server Offline (BDA-O) |
Repair of the part requires shutting down one Big Data Appliance server. No downtime of the rack is required, however, individual servers may require downtime and temporary removal from the cluster. Rebalancing the work load and data duplication may temporarily impact performance. If the system is currently running, then shut it down gracefully. See "Powering On and Off Oracle Big Data Appliance" for additional information. |
|
Parts that have the RoHS:Y or RoHS:YL designation are compliant with the European Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment Directive, as follows:
RoHS:Y compliance is based on present information and belief, this equipment/part number complies with the European Union RoHS Directive, 2002/95/EC, and amending and guidance documents, and does not contain any restricted substances above the homogeneous materials' maximum concentration values, except for selected exemptions allowed by law (excluding the exemption for lead in solders for servers, storage and storage array systems, network infrastructure equipment for switching, signaling, transmission as well as network management for telecommunications).
RoHS:YL compliance is based on present information and belief, this equipment/part number complies with the European Union RoHS Directive, 2002/95/EC, and amending and guidance documents, and does not contain any restricted substances above the homogeneous materials' maximum concentration values, except for selected exemptions allowed by law (including the exemption for lead in solders for servers, storage and storage array systems, network infrastructure equipment for switching, signaling, transmission as well as network management for telecommunications).
If a part description contained in a parts list does not contain RoHS:Y or RoHS:YL in its description, this indicates that the part is not RoHS compliant or the information necessary to confirm its compliance has yet to be provided by the product team.
The disk controllers in Sun Fire servers have battery-backed write cache to accelerate write performance. If the battery charge capacity degrades such that the battery cannot protect the cached data for a power loss of 48 hours or more, then the write cache is disabled and the disk controller switches to write through mode. This results in reduced write performance but no data loss. Sun Fire servers generate an alert when the battery charge is insufficient, the temperature is high, and when the battery should be replaced.
Battery charge capacity degrades over time, and its life expectancy is inversely proportional to the operating temperature. The worst case life expectancy of the battery in an Oracle Big Data Appliance rack is as follows:
Inlet Ambient Temperature | Battery Lifetime |
---|---|
< 25 degrees Celsius (77 degrees Fahrenheit) | 3 years |
< 32 degrees Celsius (89.6 degrees Fahrenheit) | 2 years |
Oracle replaces failed batteries at no extra charge if the battery charge capacity in the disk controllers falls below the minimum threshold. As part of Premier Support for Systems, Oracle attempts to proactively replace the batteries in an Oracle Big Data Appliance rack before the end of the estimated lifetime, on a best effort basis.
This section describes the LEDs in an Oracle Big Data Appliance rack. It contains these topics:
Table A-2 describes the LED color codes on Sun Fire X4270 M2 servers.
Table A-2 LED Status Descriptions
Component | LED Status |
---|---|
Fan module |
|
Power supply |
|
Servers |
|
Table A-3 describes the color codes of the LEDs on Sun Datacenter InfiniBand Switch 36 switches.
Table A-3 Sun Datacenter InfiniBand Switch 36 LED Status Descriptions
Component | LED Status |
---|---|
Chassis |
|
Link status |
|
Network management ports |
Link speed LED:
Activity LED:
|
Power supply |
|
Table A-4 lists the replaceable parts for Sun Fire servers, which are covered under the Premier Support for Systems warranty.
Note:
Oracle Big Data Appliance ships with two spare drives. If a drive is faulty, then the customer can replace the drive before an Oracle service representative arrives if circumstances warrant immediate action.Table A-4 Replacement Parts for a Sun Fire X4270 M2 Server
Part Number | Description | Repair Category | Repair Procedure |
---|---|---|---|
150-3993 |
Battery, 3V, 390 MAH, LITH, COIN |
BDA-O |
See section 4.6, "Servicing the Server Battery" in Sun Fire X4270 M2 Server Service Manual at
|
300-2235 |
Power supply, A249, 1200 W, 12V, 2U, RoHS:Y |
HS |
See section 3.4, "Servicing Power Supplies" in Sun Fire X4270 M2 Server Service Manual at
|
350-1502 |
Universal rack mount kit |
BDA-O |
|
371-4743 |
4 GB USB 2.0 flash drive, RoHS:Y |
BDA-O |
Not applicable |
7012433 |
3.06 GHz processor |
BDA-O |
See section 4.7, "Servicing the CPU" in Sun Fire X4270 M2 Server Service Manual at
|
371-4966 |
LV DIMM, 8 GB, DDR3, 1RX4, 1333 MHz |
BDA-O |
See section 4.7, "Servicing Memory Modules (DIMMs)" in Sun Fire X4270 M2 Server Service Manual at
|
371-4982 |
6 Gigabit SAS RAID PCI battery module, RoHS:Y (LION), BBU-08 |
BDA-O |
|
375-3696 |
InfiniBand (CX2) dual port CX2 4xQDR PCI-e |
BDA-O |
|
375-3701 |
6 Gbps SAS RAID disk PCIe HBA, RoHS:Y |
BDA-O |
Note: Do not run any controller commands in the service manual when replacing the disk. |
530-3927 |
Cable, PDB, MB, 1U+2U, ribbon |
BDA-O |
See section 5.10, "Servicing Cables " in Sun Fire X4270 M2 Server Service Manual at
|
530-4228 |
Cable, mini-SAS, 36 POS LONG, LY, RoHS:Y |
BDA-O |
See section 5.10, "Servicing Cables" in Sun Fire X4270 M2 Server Service Manual at
|
541-2075 |
Bus_bar, power, 1U+2U, RoHS:Y |
BDA-O |
See section 5.6, "Servicing the Power Distribution Board" in Sun Fire X4270 M2 Server Service Manual at
|
541-2884 |
Assembly, riser, X8, X8, 2U, PCI-E, RoHS:Y |
BDA-O |
See section 4.4, "Servicing PCIe Risers" in Sun Fire X4270 M2 Server Service Manual at
|
541-3310 |
Xeon Heatsink with grease, RoHS:Y, 2U |
BDA-O |
See section 4.7, "Servicing the CPU" in Sun Fire X4270 M2 Server Service Manual at
|
541-3356 |
x8/x8 switched PCIe riser assembly, RoHS:Y with the following:
|
BDA-O |
|
541-4081 |
System board assembly, RoHS:Y |
BDA-O |
|
541-4124 |
Fan deck, Hyde, RoHS:Y |
BDA-O |
See section 5.3, "Servicing the Fan Board" in Sun Fire X4270 M2 Server Service Manual at
|
541-4222 |
Assembly, fan, CR, 2U, RoHS:Y |
HS |
See section 3.3, "Servicing the Fan Modules" in Sun Fire X4270 M2 Server Service Manual at
|
541-4223 |
Power distribution board, 2U, RoHS:Y |
BDA-O |
See section 5.6, "Servicing the Power Distribution Board" in Sun Fire X4270 M2 Server Service Manual at
|
541-4304 |
Indicator, right, Hyde 12/24, rohs:y |
BDA-O |
See section 5.5, "Servicing the Front Panel LED Modules" in Sun Fire X4270 M2 Server Service Manual at
|
541-4305 |
Assembly, disk, SAS2, XP_DC, Hyde, RoHS:Y |
BDA-O |
See section 5.2, "Servicing the SAS Expander Board" in Sun Fire X4270 M2 Server Service Manual at
|
541-4306 |
Assembly, connector board bracket, Hyde |
BDA-O |
See section 5.7, "Servicing the Connector Board" in Sun Fire X4270 M2 Server Service Manual at
|
541-4363 |
12-slot disk backplane, RoHS:Y |
BDA-O |
See section 5.4, "Servicing the Disk Backplane" in Sun Fire X4270 M2 Server Service Manual at
|
541-4371 |
Indicator, left, Hyde 12/24, RoHS:Y |
BDA-O |
See section 5.5, "Servicing the Front Panel LED Modules" in Sun Fire X4270 M2 Server Service Manual at
|
7010036 |
FRU DR 3 TB 3.5-inch SAS/7200, CORAL |
-- |
See section 3.2, "Servicing Storage Drives and Boot Drives" in Sun Fire X4270 M2 Server Service Manual at
Note: Do not run any controller commands in the service manual when replacing the disk. |
560-2952 |
Cable kit, Hyde, RoHS:Y with the following:
|
BDA-O |
Refer to the entries for the individual items in the kit |
Table A-5 lists the replaceable parts for the InfiniBand switches used in Oracle Big Data Appliance, which are covered under the Premier Support for Systems warranty.
See "Cables and Cable Accessories for an Oracle Big Data Appliance Rack" for information about InfiniBand cables.
See Also:
Sun Network QDR InfiniBand Gateway Switch Service Manual at
http://docs.oracle.com/cd/E19671-01/821-1188-11/821-1188-11.pdf
Sun Datacenter InfiniBand Switch 36 User's Guide at
http://docs.oracle.com/cd/E19197-01/835-0784-05/gentextid-226.html
Table A-5 Replacement Parts for InfiniBand Switches
Part Number | Description | Repair Category | Repair |
---|---|---|---|
300-2143 |
760 watt power supply, RoHS:Y |
HS |
See Sun Network QDR InfiniBand Gateway Switch Service Manual or Sun Datacenter InfiniBand Switch 36 User's Guide |
350-1312 |
Fan module for Sun Datacenter InfiniBand Switch 36, RoHS:Y |
HS |
See Sun Datacenter InfiniBand Switch 36 User's Guide |
371-2210 |
CR2032 3 v battery, RoHS:Y |
IR |
See Sun Network QDR InfiniBand Gateway Switch Service Manual or Sun Datacenter InfiniBand Switch 36 User's Guide |
541-3495 |
Sun Datacenter InfiniBand Switch 36, RoHS:YL |
IR |
|
7014378 |
Assembly, system, NM2-Gateway |
IR |
See Sun Network QDR InfiniBand Gateway Switch Installation Guide at
|
594-6603 |
10 Gbps QSFP short wavelength T |
IR |
See Sun Datacenter InfiniBand Switch 36 User's Guide |
Table A-6 lists replaceable parts for the Cisco Ethernet switch, which are covered under the Premier Support for Systems warranty.
See Also:
Cisco Catalyst 4948E Switch Installation Guide for repair instructions athttp://www.cisco.com/en/US/docs/switches/lan/catalyst4900/4948E/installation/guide/4948E_ins.html
Table A-6 Replacement Parts for Cisco Ethernet Switch
Part Number | Description | Repair Category | Repair |
---|---|---|---|
310-0307 |
Cooling fan |
HS |
See Chapter 4 of Cisco Catalyst 4948E Switch Installation Guide |
371-4784 |
Cisco Catalyst 4948 switch, RoHS:Y |
IR |
See Chapter 3 of Cisco Catalyst 4948E Switch Installation Guide |
371-4785 |
Power supply |
HS |
See Chapter 4 of Cisco Catalyst 4948E Switch Installation Guide |
Table A-7 lists the replacement parts for the KVM switch and KMM tray components, which are covered under the Premier Support for Systems warranty.
See Also:
MergePoint Unity Switch Installer/User Guide for repair instructions atTable A-7 Replacement Parts for KVM Switch and KMM Tray Components
Part Number | Description | Repair Category | Repair |
---|---|---|---|
371-4778 |
Assembly, KMM, with Japanese keyboard and mouse module |
IR |
See Chapter 2 of MergePoint Unity Switch Installer/User Guide |
371-4779 |
Avocent MPU4032DAC-001 32-port KVM switch, RoHS:Y |
IR |
See Chapter 2 of MergePoint Unity Switch Installer/User Guide |
371-4780 |
Avocent KMM drawer with United States keyboard, RoHS:Y |
IR |
See Chapter 2 of MergePoint Unity Switch Installer/User Guide |
371-4781 |
Avocent (DSRIQ-USB) DB 15 M to RJ45/USB KVM adapter, RoHS:Y |
IR |
See Chapter 2 of MergePoint Unity Switch Installer/User Guide |
Table A-8 lists the replacement parts for the power distribution units (PDUs), which are covered under the Premier Support for Systems warranty.
Given the number of cables and connections, Oracle recommends shutting down the Oracle Big Data Appliance rack when replacing power distribution unit parts.
See Also:
Sun Rack II Power Distribution Units User's Guide for repair instructions atTable A-8 Replacement Parts for Power Distribution Units
Part Number | Description | Repair Category | Repair |
---|---|---|---|
180-2379 |
13A/250V 90 degree IEC 320 Sheet E to IEC 320 C13 cord, 1 meter, RoHS:Y |
HS |
Not applicable |
180-2380 |
13A/250V 90 degree IEC 320 Sheet E to IEC 320 C13 cord, 2 meter, RoHS:Y |
HS |
Not applicable |
371-3995 |
Three-phase PDU: 15 kVA, IEC309 60A, 4 pin, 250 VAC, 3ph IP67, North America, RoHS:Y |
IR |
See Chapter 3 of Sun Rack II Power Distribution Units User's Guide |
371-4000 |
Three-phase PDU: 15 kVA, 5-Pin, IEC309 32A, 5 pin 230/400V, 3ph IP44, international, RoHS:Y |
IR |
See Chapter 3 of Sun Rack II Power Distribution Units User's Guide |
371-4199 |
Single-phase PDU: 15 kVA, with three 30A/250V 2-pole/3-wire NEMA L6-30P plugs, North America, RoHS:Y |
IR |
See Chapter 3 of Sun Rack II Power Distribution Units User's Guide |
371-4201 |
Single-phase PDU: 15 kVA, with three blue 32A/240V splash-proof 2-Pole/3-Wire IEC 60309 plugs, international, RoHS:Y |
IR |
See Chapter 3 of Sun Rack II Power Distribution Units User's Guide |
Table A-9 lists the replacement cables and cable accessories, which are covered under the Premier Support for Systems warranty.
See Also:
Sun Network QDR InfiniBand Gateway Switch Service Manual at
http://docs.oracle.com/cd/E19671-01/821-1188-11/821-1188-11.pdf
Sun Datacenter InfiniBand Switch 36 User's Guide at
http://docs.oracle.com/cd/E19197-01/835-0784-05/gentextid-226.html
See Cisco Catalyst 4948E Switch Installation Guide at
http://www.cisco.com/en/US/docs/switches/lan/catalyst4900/4948E/installation/guide/4948E_ins.html
Table A-9 Replacement Cables for an Oracle Big Data Appliance Rack
Part Number | Description | Repair Category | Repair |
---|---|---|---|
350-1287 |
Slim rail, CMA, 1U-2U for Sun Fire servers |
BDA-O |
|
350-1519 |
Serial cable kit, RoHS:Y with the following:
|
HS |
See Sun Datacenter InfiniBand Switch 36 User's Guide |
530-4403 |
4x QSFP copper QDR InfiniBand cable, 2 m, RoHS:Y |
HS |
Note: There is a loss of redundancy when replacing cables. |
530-4404 |
4x QSFP copper QDR InfiniBand cable, 3 m, RoHS:Y |
HS |
|
530-4415 |
4x QSFP copper QDR InfiniBand cable, 5 m, RoHS:Y |
HS |
|
530-4432 |
Ethernet cable, Cat 5/5E, RJ45 to RJ45, 7 foot, blue, RoHS:Y |
HS |
See Cisco Catalyst 4948E Switch Installation Guide |
530-4433 |
Ethernet cable, Cat 5/5E, RJ45 to RJ45, 10 foot, red, RoHS:Y |
HS |
See Cisco Catalyst 4948E Switch Installation Guide |
530-4434 |
Ethernet cable, Cat 5/5E, RJ45 to RJ45, 7 foot, red, RoHS:Y |
HS |
See Cisco Catalyst 4948E Switch Installation Guide |
530-4435 |
Ethernet cable, Cat 5/5E, RJ45 to RJ45, 10 foot, black, RoHS:Y |
HS |
See Cisco Catalyst 4948E Switch Installation Guide |
530-4436 |
Ethernet cable, Cat 5/5E, RJ45 to RJ45, 7 foot, black, RoHS:Y |
HS |
See Cisco Catalyst 4948E Switch Installation Guide |
530-4437 |
Ethernet cable, Cat 5/5E, RJ45 to RJ45, 7 foot, orange, RoHS:Y |
HS |
See Cisco Catalyst 4948E Switch Installation Guide |
530-4438 |
Ethernet cable, Cat 5/5E, RJ45 to RJ45, 10 foot, black, RoHS:Y |
HS |
See Cisco Catalyst 4948E Switch Installation Guide |