FMA shell 是获取详细故障信息的首选方法,因为它可呈现最全面的故障视图。
-> start /SP/faultmgmt/shell
Do you want to start the /SP/faultmgmt/shell (y/n)? y
faultmgmtsp> fmadm faulty
------------------- ------------------------------------ -------------- --------
Time UUID msgid Severity
------------------- ------------------------------------ -------------- --------
2015-09-27/12:04:56 388a8916-3257-ea2a-c7b7-b62bf2f210f8 SPT-8000-7J Minor
Problem Status : open
Diag Engine : fdd 1.0
System
Manufacturer : Oracle Corporation
Name : SPARC M7-8
Part_Number : 7087407
Serial_Number : AK00180227
System Component
Manufacturer : Oracle Corporation
Name : SPARC M7-8
Part_Number : 32397572+5+1
Serial_Number : AK00185563
----------------------------------------
Suspect 1 of 1
Fault class : fault.chassis.power.missing
Certainty : 100%
Affects : /SYS/PS1
Status : not present
FRU
Status : faulty
Location : /SYS
Manufacturer : Oracle Corporation
Name : SPARC M7-8
Part_Number : 32397572+5+1
Serial_Number : AK00185563
Chassis
Manufacturer : Oracle Corporation
Name : SPARC M7-8
Part_Number : 32397572+5+1
Serial_Number : AK00185563
Description : A power supply unit is absent.
Response : The service-required LED on the chassis will be illuminated.
Impact : Server will be powered down when there are insufficient
operational power supplies.
Action : Please refer to the associated reference document at
http://support.oracle.com/msg/SPT-8000-7J for the latest
service procedures and policies regarding this diagnosis.
faultmgmtsp> exit
->
如果命令的输出显示了故障组件,请参阅SPARC M7 Series Servers Service Manual。