OPOS MC reader

The program description deals with the following:

Remarks on program function

The data for an OPOS magnetic card reader can be updated, i.e. programmed, changed or cleared, with this program. Data which has already been stored can also be displayed for information.

Enter the number of the device under which it is to be stored in the system. The interface and link to a processing unit should be defined and the device-specific operating mode set.

Note:
99 = zero should be selected as device interface for all OPOS devices.

The OPOS modules must have been installed and configured to allow OPOS devices to be operated.

Click on the graphic for further help with programming of an OPOS Device.


Remarks on data fields

The following description deals with all available options for update of this basic data.

As with nearly all other programs the following also applies here:


Service name

Entry range permitted: alphanumeric max. 30 chars.

Note
The entry in this field is option and only necessary if no entry has been made in field Device name.

Example:
The OPOS modules are entered as follows in the registration database:

·        HKEY_LOCAL_MACHINE\SOFTWARE\OLEforRetail\ ServiceOPOS\Gerätegruppe\Gerätename\

The service names are listed in program regedit:

The device names can be found in the left-hand directory in the device group for the device concerned, e.g. "ADSTopCAshCentralLock".

The linked service names can be found in the right-hand directory under code "Standard" = "ADSTopCash.CentralLock.1".

 

Click on the graphic for further help with programming of OPOS Devices.


Device name

Entry range permitted: alphanumeric max. 30 chars.

Enter the device name of this OPOS device.

Exmple

The OPOS modules are entered as follows in the registration database:

·        HKEY_LOCAL_MACHINE\SOFTWARE\OLEforRetail\ ServiceOPOS\Gerätegruppe\Gerätename

The device names are listed in program regedit.

The linked device names can be found in the left-hand directory under the device group concerned.

Click on the graphic for further help with programming of OPOS Device


Debug

Entry range permitted: numeric 0 - 255

Select one of the offered debug levels by clicking onto this field and with a second click confirming the selection.

The system offers the following debug levels:

Note:
Only select a value higher than "0" for the debug level if a protocol of the communications is required for error analysis. The details are shown in file "errlog" in directory work of the appropriate system unit.


Multithreaded

Button active: Multithreaded is switched on
Button deactivated: Multithreaded is switched off

This option is dependent on the connected device and must be activated or deactivated accordingly.


Index


MICROS Retail Deutschland GmbH
Salzufer 8
D-10587 Berlin