다음 절차를 수행하여 클러스터화된 어플라이언스의 첫번째 컨트롤러(컨트롤러 A)를 업그레이드할 수 있습니다.
controller-a:> maintenance system reboot This will reboot the appliance. Are you sure? (Y/N) y
아래의 예에서 컨트롤러 A의 상태는 수동 상태인 AKCS_STRIPPED입니다.
controller-a:> configuration cluster show state = AKCS_STRIPPED ... peer_state = AKCS_OWNER peer_description = Active
클러스터화된 상태에 대한 자세한 내용은 Oracle ZFS Storage Appliance 관리 설명서, 릴리스 OS8.6.0 의 클러스터 인계 및 페일백을 참조하십시오.
controller-a:> maintenance system updates controller-a:maintenance system updates> show Updates: UPDATE DATE STATUS ak-nas@2013.06.05.1.1,1-1.2 2013-12-6 23:37:50 previous ak-nas@2013.06.05.2.0,1-1.9 2014-5-28 15:20:06 current ak-nas@2013.06.05.3.0,1-1.14 2014-12-19 14:31:49 waiting
controller-a:maintenance system updates> select ak-nas@2013.06.05.3.0,1-1.14
controller-a:maintenance system updates ak-nas@2013.06.05.3.0,1-1.14> check You have requested to run checks associated with waiting upgrade media. This will execute the same set of checks as will be performed as part of any upgrade attempt to this media, and will highlight conditions that would prevent successful upgrade. No actual upgrade will be attempted, and the checks performed are of static system state and non-invasive. Do you wish to continue? Are you sure? (Y/N) y
업데이트 진행 중 컨트롤러 A가 자동으로 재부트됩니다.
controller-a:maintenance system updates ak-nas@2013.06.05.3.0,1-1.14> upgrade This procedure will consume several minutes and requires a system reboot upon successful update, but can be aborted with [Control-C] at any time prior to reboot. A health check will validate system readiness before an update is attempted, and may also be executed independently using the check command. Are you sure? (Y/N) y
controller-a:> maintenance system updates firmwareUpdatesDetails Pending No Pending Updates Failed No Failed Updates In Progress No Updates in Progress
controller-a:> maintenance hardware show Chassis: NAME STATE MANUFACTURER MODEL SERIAL RPM ... disk-000 HDD 0 ok SEAGATE ST330057SSUN300G 001117G1G929 6SJ1G929 15000 disk-001 HDD 1 ok SEAGATE ST330057SSUN300G 001117G1GA8Y 6SJ1GA8Y 15000 disk-002 HDD 2 ok SEAGATE ST330057SSUN300G 001117G1KDPZ 6SJ1KDPZ 15000 ...
풀은 온라인 상태이고 오류가 없어야 합니다.
controller-a:> configuration storage show Pools: POOL OWNER DATA PROFILE LOG PROFILE STATUS ERRORS -> pool25 brm7320-250 - - online 0 pool26 brm7320-260 - - online 0
컨트롤러 A가 이제 업그레이드되었습니다.
컨트롤러 B 업그레이드 - CLI