# ldm ls-io -l
NAME TYPE BUS DOMAIN STATUS
---- ---- --- ------ ------
pci_1 BUS pci_1 primary IOV
[pci@340]
pci_0 BUS pci_0 primary
[pci@300]
pci_3 BUS pci_3 primary
[pci@3c0]
pci_2 BUS pci_2 primary IOV
[pci@380]
/SYS/MB/PCIE5 PCIE pci_1 primary OCC
[pci@340/pci@1/pci@0/pci@4]
pciex108e,2088@0/ibport@1,0,ipib
pciex108e,2088@0/ibport@2,0,ipib
[pci@380/pci@1/pci@0/pci@6]
/SYS/MB/PCIE4 PCIE pci_2 primary OCC
[pci@380/pci@1/pci@0/pci@7]
pciex108e,2088@0/ibport@1,0,ipib
pciex108e,2088@0/ibport@2,0,ipib
pciex108e,2089@0,1
pciex108e,2089@0,2
pciex108e,2089@0,3
pciex108e,2089@0,4
/SYS/MB/PCIE5/IOVGEN.PF0 PF pci_1 primary
[pci@340/pci@1/pci@0/pci@4/pciex108e,2088@0]
maxvfs = 32
/SYS/MB/NET0/IOVNET.PF0 PF pci_0 primary
[pci@300/pci@1/pci@0/pci@1/network@0]
maxvfs = 63
/SYS/MB/NET0/IOVNET.PF1 PF pci_0 primary
[pci@300/pci@1/pci@0/pci@1/network@0,1]
maxvfs = 63
/SYS/MB/NET2/IOVNET.PF0 PF pci_3 primary
[pci@3c0/pci@1/pci@0/pci@1/network@0]
maxvfs = 63
/SYS/MB/NET2/IOVNET.PF1 PF pci_3 primary
[pci@3c0/pci@1/pci@0/pci@1/network@0,1]
maxvfs = 63
/SYS/MB/PCIE4/IOVGEN.PF0 PF pci_2 primary
[pci@380/pci@1/pci@0/pci@7/pciex108e,2088@0]
maxvfs = 32
/SYS/MB/PCIE5/IOVGEN.PF0 PF pci_1 primary [pci@340/pci@1/pci@0/pci@4/pciex108e,2088@0]
其中 2088 是设备 ID。
在主域重新引导之前,将禁用对其他域进行的所有配置更改,在此期间,主域的新配置仍有效。
#ldm start-reconf primary
#ldm create-vf /SYS/MB/PCIE4/IOVGEN.PF0
#ldm add-io /SYS/MB/PCIE4/IOVGEN.PF0.VF0 ldom
有关 VF 的其他信息,请参阅《Oracle VMServer for SPARC 3.3 管理指南》,网址为:http://www.oracle.com/technetwork/documentation/vm-sparc-194287.html。