Completing the Quality / Inspection Subtab

To add an advanced manufacturing work bench test, complete the Quality / Inspection subtab.

To complete the quality / inspection subtab:

  1. Click the Quality / Inspection subtab.

  2. Click New AM Mfg Work Bench Tests.

  3. In the AM Mfg Work Bench Tests form, in the Operation Task Inspection section, complete the following steps:

    1. Select an Item from the list.

    2. (Optional) Select a Test Name from the list.

      NetSuite populates the Inspection Method, Inspection Type, and Inspection Results fields with the test’s details.

    3. Select an Inspection Method from the list.

      For example, Visual Count or Measurement.

    4. Enter a Description of the test.

    5. Enter the name of the Quality Management System Reference.

    6. Enter the Operation Inspection Sequence number.

  4. In the Measurements Standards and Attributes section, complete the following steps:

    1. Select an Inspection Type from the list.

      For example, Standard Result or Requires Sampling.

    2. Select an Inspection Results measure from the list.

      For example, Pass/Fail or Measurement.

    3. Enter a Sample Size.

    4. Select a Sample Frequency from the list.

      For example, Each Unit, Each Batch, Each Lot, One Sample Per Run, Once Per Operation, or Every Hour.

    5. Select an Evaluation Criteria from the list.

      For example, Test Passes or Fails, Percentage of Sample Passes, Average of Sample Values in Tolerance, or Measurement Only.

    6. Enter a Minimum Percent number.

    7. Enter a Target Value.

    8. Enter an Upper Control Limit and a Lower Control Limit.

    9. Select a Unit of Measure from the list.

      For example, Each or Lb.

    10. Select a Default Corrective Measure from the list.

      For example, Open Repair Order, Cancel Work Order, or Work Order On Hold, or No Action Required.

  5. In the Parameters section, complete the following steps:

    1. If this is a pass or fail test, check the Pass Fail Test box.

    2. If you require a test pass or fail certification, check the Certificate Required box.

    3. If you require a test pass or fail signature, check the Signature Required box.

    4. If this test is required, check the This Test is Mandatory box.

  6. To include a note for this test, in the Notes subtab, complete the following steps:

    1. Enter a Title.

    2. Enter a Memo.

    3. Select a memo Type from the list.

    4. Select a memo Direction from the list.

    5. To include additional notes, click Add, and then repeat steps a-d.

  7. To attach a file to this test, click the Files subtab, and then do one of the following in the Attach File field:

    • To select an existing file in NetSuite, click the double arrow, and then click List.

    • To select a new file, click the plus icon, complete the File form, and then click Save.

    1. To include additional files, click Add, and then repeat step 7.

  8. Click Save.

Related Topics

Completing the Planning Subtab
Completing the Assets Subtab
Completing the Labor Requirement Subtab
Completing the Work Instructions Subtab
Creating Manufacturing Work Benches