27 Replacement Units

This appendix lists the replacement units for Recovery Appliance. It contains the following topics:

About Warranty Coverage

All replaceable parts are field replaceable units (FRUs) under the Oracle Premier Support for Systems warranty. Oracle field engineers install the replacement parts.

Understanding Repair Categories

Repair categories describe the potential impact of a repair action. Table 27-1 describes the categories and actions.

Table 27-1 Recovery Appliance Repair Categories

Category Description Examples

Hot Swap (HS)

Repair part is hot swappable, and can be replaced without shutting down the host system. Commands might be required before and after replacement to protect data.

  • Disks

  • Fans

  • Power supplies

Infrastructure Repair (IR)

Repairing a connectivity component within the Recovery Appliance rack. No downtime of the rack is required; however, individual components may require downtime.

  • Ethernet switch

  • External cables

  • InfiniBand switch

Compute Server Offline (DBO)

Repairing the part requires shutting down a compute server. No downtime of the rack is required; however, individual servers might require downtime, and they might be taken outside of the cluster temporarily.

If the server is currently running, then you must shut it down. See "Powering Down the Servers".

If you monitor the system using Oracle Enterprise Manager Grid Control, then avoid unnecessary alerts by putting the target in a blackout state. Refer to Oracle Enterprise Manager Administration for additional information.

  • Memory

  • PCIe cards

  • PDUs

  • Processors

  • System boards

Storage server Offline (EBO)

Repairing the part requires shutting down a storage server within the rack. No downtime of the rack is required; however, individual servers might require downtime, and they might be taken outside of the cluster temporarily. There also might be a temporary performance impact, while the system rebalances to maintain data redundancy.

If the server is currently running, then you must shut it down. See "Powering Down the Servers".

If you monitor the system using Oracle Enterprise Manager Grid Control, then avoid unnecessary alerts by putting the target in a blackout state. Refer to Oracle Enterprise Manager Administration for additional information.

  • Memory

  • PCIe cards

  • Processors

  • System boards

LED Status Descriptions

This section describes the LEDs.

Oracle Server LEDs

Table 27-2 identifies the LED status indicators that can indicate faults on the compute servers and the storage servers.

Table 27-2 Oracle Server LED Status Descriptions

Component LED Status

General Status

The following LEDs are located on the front and back panels of each server:

Service Required (amber)

Off indicates normal operation.

Steady on indicates a fault in the server.

Power/OK (green)

Steady on indicates that the server is powered on.

A slow blink indicates that the server is starting up.

A steady blink indicates that standby power is on, but chassis power is off.

Off indicates no AC power or an incomplete startup of Oracle ILOM.

Fans

Each fan module has one bicolored LED, which you can see when the top cover fan door is open.

Fan Status (amber/green)

Amber indicates that the fan module is faulty. The front and rear panel Service Required LEDs are also lit when the system detects a fan module fault.

Green indicates that the system is powered on, and the fan module is functioning correctly.

Drives

The following LEDs are located on the storage and boot drives:

Service Required (amber)

Off indicates normal operation.

Steady on indicates a fault in the drive.

OK/Activity (green)

Steady on indicates normal inactivity.

A steady blink indicates normal activity.

Off indicates that the power is off, or the system does not recognize the drive.

Power supply

The following LEDs are on each power supply. You can see them from the back of the server.

Service Required (amber)

Off indicates normal operation.

Steady on indicates that the system has detected a problem in the power supply regarding the voltage, current, temperature, or fans.

AC OK/DC OK (green)

Steady on indicates normal operation for both AC and DC power.

A slow blink indicates that input AC power is normal and output DC power is disabled.

Off indicates no input AC power.

See Also:

Sun Datacenter InfiniBand Switch 36 LEDs

Table 27-3 identifies the LED status indicators that can indicate faults on Sun Datacenter InfiniBand Switch 36.

Table 27-3 Sun InfiniBand Switch LED Status Descriptions

Component LED Status

Chassis

The following LEDs are located on the left side of the rear panel.

Attention (amber)

Steady on indicates a fault.

Off indicates normal operation.

Flashing indicates no function.

OK (green)

Steady on indicates normal operation.

Off indicates that the switch is off or initializing.

Flashing indicates no function.

Link status

The link status LEDs are located by the data cable connectors on the rear panel.

Link (green)

Steady on indicates that a link is established.

Off indicates that the link is down.

Flashing indicates that there are symbol errors.

Network management ports

The following LEDs are located on the network management connector on the rear panel.

Link Speed (amber/green):

Green steady on indicates a 1000BASE-T link.

Amber steady on indicates a 100BASE-T link.

Off indicates no link.

Flashing indicates no function.

Activity (green):

Flashing indicates packet activity.

On indicates no function.

Off indicates no activity.

Power supply

The following LEDs are located on the power supply at the front of the chassis.

Attention (amber)

Steady on indicates a fault, and 12 VDC is shut down.

Off indicates normal operation.

Flashing indicates no function.

OK (green)

Steady on indicates 12 VDC.

Off indicates no DC voltage.

Flashing indicates no function.

AC LED is green

Steady on indicates AC power is supplied.

Off indicates that AC power is not present.

Flashing indicates no function.

Fan

The following LED is located on the air inlet on the front of the chassis.

FT

On indicates a problem with the fan.

Off indicates normal operation

See Also:

"Identifying LEDs" in the Sun Datacenter InfiniBand Switch 36 Service Manual at

http://docs.oracle.com/cd/E26698_01/html/E26434/z40000fe1394411.html

Parts for Compute Servers

The following topics identify the replacement parts for the Recovery Appliance compute servers:

Database Server Components of Recovery Appliance X9M-2

Each Recovery Appliance X9M-2 database server includes the following components:

  • CPU - 32-core Intel Xeon 8358 processors (2.6 GHz):
    • Flexible configuration: 2 CPUs
    • Eighth Rack: 1 CPU
  • RAM:
    • Flexible configuration: 512 GB RAM (16 x 32 GB DIMMs), expandable to 1 TB (16 x 64 GB DIMMs), 1.5 TB (16 x 32 GB and 16 x 64 GB DIMMs), or 2 TB (32 x 64 GB DIMMs) with memory expansion kit
    • Eighth Rack: 384 GB RAM (12 x 32 GB DIMMs), expandable to 1 TB (16 x 64 GB DIMMs) with memory expansion kit
  • System storage: 2 x 3.84 TB PCIe 4.0 NVMe storage drives, expandable to 4 drives
  • RDMA Network Fabric: 1 x dual-port CX5 RDMA Network Fabric card; PCIe 4.0, 2 x 100 Gb/s ports active-active (200 Gb/s combined throughput)
  • Administration network: 1 x 1 GbE Base-T Ethernet port
  • Integrated Lights Out Manager (ILOM) port for remote management: 1 x 1 GbE Base-T Ethernet port
  • Client and additional network connectivity:
    • Flexible configuration options:
      • Two factory-installed network cards. Each card contains 2 x SFP+/SFP28 ports (10/25 GbE) or 4 x 10GBASE-T ports (10 GbE)
      • One optional field-installed network card containing 2 x SFP+/SFP28 ports (10/25 GbE) or 4 x 10GBASE-T ports (10 GbE) or 2 x QSFP28 ports (100GbE). Each QSFP28 port can support one 10 GbE or 25 GbE link with appropriate breakout cables.
    • Eighth Rack: Two factory-installed network cards only. Each card contains 2 x SFP+/SFP28 ports (10/25 GbE) or 4 x 10GBASE-T ports (10 GbE)

Database Server Components of Recovery Appliance X8M-2

Recovery Appliance X8M-2 database servers include the following components:

  • 2 x 24-core Intel Xeon Platinum 8260 Processors (2.4 GHz)
  • 384 GB RAM (12 x 32 GB DIMMs), expandable to 1.5 TB (24 x 64 GB DIMMs) with memory expansion kit
  • 4 x 1.2 TB boot drive/hard disks, hot swappable, expandable to 8 drives
  • Disk controller HBA with 2 GB cache (no batteries)
  • RDMA Network Fabric: 1 x dual-port QSFP28 100 Gb/s PCIe 3.0 RDMA Network Fabric card - both ports active
  • Client network: 2 x SFP+/SFP28 ports (10/25 GbE) or 2 x 10GBASE-T ports (10 GbE)
  • Backup/optional networks: 2 x SFP+/SFP28 ports (10/25 GbE) or 4 x 10GBASE-T ports (10 GbE)
  • Administration network: 1 x 1 GbE Base-T Ethernet port
  • Integrated Lights Out Manager (ILOM) port for remote management: 1 x 1 GbE Base-T Ethernet port

Oracle Server X8-2 and X8M-2 Database Server Parts

The following image shows the front view of Oracle Server X8-2 and X8M-2 Database Servers.

Figure 27-1 Front View of Oracle Server X8-2 and X8M-2 Database Servers

Description of Figure 27-1 follows
Description of "Figure 27-1 Front View of Oracle Server X8-2 and X8M-2 Database Servers"

The following image shows the rear view of the Oracle Server.

Figure 27-2 Rear View of Oracle Server X8-2 and X8M-2 Database Servers

Description of Figure 27-2 follows
Description of "Figure 27-2 Rear View of Oracle Server X8-2 and X8M-2 Database Servers"

The following table lists the replaceable parts for Oracle Server X8-2 and X8M-2 database servers. Refer to this table only if you have a basic warranty. All replacement parts shown in the following table are considered FRU when covered under Premier Support of Systems warranty.

Table 27-4 Replacement Parts for Oracle Server X8-2 and X8M-2 Database Servers

Part Number Description Repair Category Coverage under Basic Warranty Repair Procedure

370-5621-01

3 volt lithium battery grover

DBO

FRU

See "Servicing the Battery (CRU)" in Oracle Exadata X8-2 Database Server Service Manual at http://docs.oracle.com/cd/E93359_01/html/E93386/gqviw.html#scrolltoc

7363537

ASSY DRV 1.2TB 10KRPM SAS3 512N SFF MARLIN

DBO

FRU

See "Servicing Storage Drives (CRU)" in Oracle Exadata X8-2 Database Server Service Manual at http://docs.oracle.com/cd/E93359_01/html/E93386/gquak.html#scrolltoc

7322171

ASM LFIM

DBO

FRU

See "Servicing Other Cables (FRU)" in Oracle Exadata X8-2 Database Server Service Manual at http://docs.oracle.com/cd/E93359_01/html/E93386/gqvev.html#scrolltoc

7339763

BD LP DUAL SFP28 ADAPTER WHITNEY+ PCIe3.0x8

DBO

CRU

  1. If the server is currently running, then it should be shut down gracefully. See "Stopping Recovery Appliance Services" for additional information.
  2. See "Servicing PCIe Cards (CRU)" in Oracle Exadata X8-2 Database Server Service Manual at http://docs.oracle.com/cd/E93359_01/html/E93386/gqvjk.html#scrolltoc

8200663

HEATSINK CPU HEIGHT:23.5 MM

DBO

FRU

See "Servicing Processors (FRU)" in Oracle Exadata X8-2 Database Server Service Manual at http://docs.oracle.com/cd/E93359_01/html/E93386/gqtmk.html#scrolltoc

7343599

Assembly, riser, 1-slot, 1U

DBO

FRU

See "Servicing PCIe Risers (CRU)" in Oracle Exadata X8-2 Database Server Service Manual at http://docs.oracle.com/cd/E93359_01/html/E93386/gqvft.html#scrolltoc

7330698

DIMM, 32 GB, RDIMM, DDR4, 2666 2Rx4 1.2V

DBO

CRU

See "Servicing the DIMMs (CRU)" in Oracle Exadata X8-2 Database Server Service Manual at https://docs.oracle.com/en/servers/x86/x8-2l/exadata-db-service-manual/gqvkr.html

8200116

Power supply, AC, A266, F, 12V, 1200W

HS

CRU

  1. Remove rear left side of the CMA, and then swing it back and out to the right.

    The telescopic cross member supporting the cables directly behind the server can be retracted to access both power supplies.

  2. See "Servicing Power Supplies (CRU)" in Oracle Exadata X8-2 Database Server Service Manual at http://docs.oracle.com/cd/E93359_01/html/E93386/gqunc.html#scrolltoc

  3. Replace the CMA.

7332895

HBA, 12 Gb SAS PCIe 16-port RAID internal with flash module

DBO

FRU

See "Servicing the Internal HBA Card and HBA Super Capacitor (FRU)" in Oracle Exadata X8-2 Database Server Service Manual at http://docs.oracle.com/cd/E93359_01/html/E93386/gqvmq.html#scrolltoc

7086345

Assembly, super cap, 13.5 volt, 6.4F, SAS3 HBA

DBO

FRU

See "Servicing the Internal HBA Card and HBA Super Capacitor (FRU)" in Oracle Exadata X8-2 Database Server Service Manual at http://docs.oracle.com/cd/E93359_01/html/E93386/gqvmq.html#scrolltoc

7340897

Cable, SAS3 to HBA

DBO

CRU

See "Servicing the Internal HBA Cables" in Oracle Exadata X8-2 Database Server Service Manual at http://docs.oracle.com/cd/E93359_01/html/E93386/gqvav.html#scrolltoc

7331123

Assembly, fan module

HS

CRU

See "Servicing Fan Modules (CRU)" in Oracle Exadata X8-2 Database Server Service Manual at http://docs.oracle.com/cd/E93359_01/html/E93386/gquhg.html#scrolltoc

8200428

CPU INTEL CLX P8260 (B1) 2.4 GHz 165W 24c 8S 1TB (S-RF9H)

DBO

FRU

See "Servicing Processors (FRU)" in Oracle Exadata X8-2 Database Server Service Manual at http://docs.oracle.com/cd/E93359_01/html/E93386/gqtmk.html#scrolltoc

7104073

Assembly, Dual 40Gb/Sec (4x) QDR RDMA Fabric Host Channel Adapter Module M3

DBO

CRU

  1. If the server is currently running, then it should be shut down gracefully. See "Stopping Recovery Appliance Services" for additional information.

  2. See "Servicing PCIe Cards (CRU)" in Oracle Exadata X8-2 Database Server Service Manual at http://docs.oracle.com/cd/E93359_01/html/E93386/gqvjk.html#scrolltoc

  3. See "Configuring the InfiniBand Switches"

7046442 (X8-2)

Assembly, Dual port, QDR CX3, HCA

DBO

CRU

  1. If the server is currently running, then it should be shut down gracefully. See "Stopping Recovery Appliance Services" for additional information.

  2. See "Servicing PCIe Cards (CRU)" in Oracle Exadata X8-2 Database Server Service Manual at http://docs.oracle.com/cd/E93359_01/html/E93386/gqvjk.html#scrolltoc

  3. See "Configuring the InfiniBand Switches"

7119792 (X8M-2)

CX5 100GbE Adapter Dual Port QSFP28

DBO

CRU

  1. If the server is currently running, then it should be shut down gracefully. See "Stopping Recovery Appliance Services" for additional information.

  2. See "Servicing PCIe Cards (CRU)" in Oracle Exadata X8-2 Database Server Service Manual at http://docs.oracle.com/cd/E93359_01/html/E93386/gqvjk.html#scrolltoc

  3. See Verifying the RoCE Network Fabric Configuration.

7360829

Assembly, motherboard, 1U

DBO

FRU

  1. See "Servicing the Motherboard Assembly (FRU)" in Oracle Exadata X8-2 Database Server Service Manual at http://docs.oracle.com/cd/E93359_01/html/E93386/gqvfa.html#scrolltoc

  2. Press F2 after restarting the server.

  3. Set the boot order.

7331100

Assembly, riser, 2-slot, 1U

DBO

FRU

See "Servicing PCIe Risers (CRU)" in Oracle Exadata X8-2 Database Server Service Manual at http://docs.oracle.com/cd/E93359_01/html/E93386/gqvft.html#scrolltoc

7331142

Assembly, Front LED indicator module

DBO

FRU

See "Servicing the Front LED Indicator Module (FRU)" in Oracle Exadata X8-2 Database Server Service Manual at http://docs.oracle.com/cd/E93359_01/html/E93386/gqvok.html#scrolltoc

Parts for Storage Servers

The following topics identify the replacement parts for the Recovery Appliance storage servers:

Oracle Exadata Storage Server X9M-2, X8M-2, and X8-2 High Capacity and Extended (XT) Server Parts

The following figure shows the front view of the Oracle Exadata Storage Server X9M-2, X8M-2 and X8-2 High Capacity and XT servers.

Note:

The Recovery Appliance supports Oracle Exadata Storage Server high capacity servers and does not use Oracle Exadata Storage Server XT servers. Both are discussed for completeness and compatibility with Oracle Exadata documentation.

Figure 27-3 Front View of Oracle Exadata Storage Server X9M-2, X8M-2 and X8-2 High Capacity and XT servers

Description of Figure 27-3 follows
Description of "Figure 27-3 Front View of Oracle Exadata Storage Server X9M-2, X8M-2 and X8-2 High Capacity and XT servers "

The following figure shows the rear view of the Oracle Exadata Storage Server X8M-2 and X8-2 High Capacity and XT servers.

Note:

The Recovery Appliance does not support XT servers.

Figure 27-4 Rear View of Oracle Exadata Storage Server X9M-2, X8M-2 and X8-2 High Capacity and XT servers

Description of Figure 27-4 follows
Description of "Figure 27-4 Rear View of Oracle Exadata Storage Server X9M-2, X8M-2 and X8-2 High Capacity and XT servers "

The following table lists the replaceable parts for Oracle Exadata Storage Server X9M-2, X8M-2 and X8-2 High Capacity and XT servers. Refer to this table only if you have a basic warranty. All replacement parts shown in the following table are considered FRU when covered under Premier Support of Systems warranty.

Note:

The Recovery Appliance supports Oracle Exadata Storage Server high capacity servers and does not use Oracle Exadata Storage Server XT servers. Both are discussed for completeness and compatibility with Oracle Exadata.

Table 27-5 Replacement Parts for Oracle Exadata Storage Server X8M-2 and X8-2 High Capacity and XT Servers

Part Number Description Repair Category Coverage under Basic Warranty Repair Procedure

370-5621-01

3 volt lithium battery grover

EBO

FRU

See "Servicing the Battery" in Oracle Exadata Storage Server X8-2 EF, HC, and XT Service Manual at http://docs.oracle.com/cd/E93361_01/html/E93395/gqtff.html#scrolltoc

7322171

Assembly, Front LED Indicator Module (LFIM)

EBO

FRU

See "Servicing the Front LED Indicator Module" in Oracle Exadata Storage Server X8-2 EF, HC, and XT Service Manual at http://docs.oracle.com/cd/E93361_01/html/E93395/gqtpg.html#scrolltoc

7341141

Assembly, 12-slot disk backplane

EBO

FRU

See "Servicing the Disk Backplane" in Oracle Exadata Storage Server X8-2 EF, HC, and XT Service Manual at http://docs.oracle.com/cd/E93361_01/html/E93395/gqtsb.html#scrolltoc

8200116

Power Supply, A266 F, 1200W, AC Input

HS

FRU

  1. Remove rear left side of the CMA, and then swing it back and out to the right.

    The telescopic cross member supporting the cables directly behind the server can be retracted to access both power supplies.

  2. See "Servicing Power Supplies" in Oracle Exadata Storage Server X8-2 EF, HC, and XT Service Manual at http://docs.oracle.com/cd/E93361_01/html/E93395/gqtag.html#scrolltoc

  3. Replace the CMA.

7322166

Fan assembly, 2U

HS

FRU

See "Servicing Fan Modules" in Oracle Exadata Storage Server X8-2 EF, HC, and XT Service Manual at http://docs.oracle.com/cd/E93361_01/html/E93395/gqtak.html#scrolltoc

7046442 (X8-2)

Assembly, dual port, QDR CX3, Host Channel Adapter

EBO

FRU

  1. If the server is currently running, then it should be shut down gracefully. See "Stopping Recovery Appliance Services" for additional information.

  2. See "Servicing PCIe Cards" in Oracle Exadata Storage Server X8-2 EF, HC, and XT Service Manual at http://docs.oracle.com/cd/E93361_01/html/E93395/gqtcq.html#scrolltoc

  3. See "Configuring the InfiniBand Switches"

  4. Verify the new hardware meets the hardware and firmware specifications using the following command:

    /opt/oracle.SupportTools/CheckHWnFWprofile

7119792

(X8M-8)

CX5 100GbE Adapter Dual Port QSFP28

DBO CRU
  1. If the server is currently running, then it should be shut down gracefully. See "Stopping Recovery Appliance Services" for additional information.

  2. See "Servicing PCIe Cards" in Oracle Exadata Storage Server X8-2 EF, HC, and XT Service Manual at http://docs.oracle.com/cd/E93361_01/html/E93395/gqtcq.html#scrolltoc

  3. See "Configuring the InfiniBand Switches"

  4. Verify the new hardware meets the hardware and firmware specifications using the following command:

    /opt/oracle.SupportTools/CheckHWnFWprofile

7322160

Heat sink, CPU

EBO

FRU

See "Servicing Processors" in Oracle Exadata Storage Server X8-2 EF, HC, and XT Service Manual at http://docs.oracle.com/cd/E93361_01/html/E93395/gqtmk.html#scrolltoc

7357761

Assembly, Drive, 14TB 3.5" SAS3/7200 rpm Coral with encryption

HS

FRU

See "Servicing Storage Drives" in Oracle Exadata Storage Server X8-2 EF, HC, and XT Service Manual at http://docs.oracle.com/cd/E93361_01/html/E93395/gqtcs.html#scrolltoc

7353916

RDIMM 16GB, DDR4 2666, 1Rx4 1.2V

EBO

FRU

See "Servicing the DIMMs" in Oracle Exadata Storage Server X8-2 EF, HC, and XT Service Manual at https://docs.oracle.com/en/servers/x86/x8-2l/exadata-storage-service-manual/gqtcm.html

7332895

HBA, 12 Gbps SAS PCIe 16-port internal RAID with flash module

EBO

FRU

See "Servicing the Internal HBA Card and HBA Super Capacitor" in Oracle Exadata Storage Server X8-2 EF, HC, and XT Service Manual at http://docs.oracle.com/cd/E93361_01/html/E93395/gqtjv.html#scrolltoc

7086345

Assembly, super cap, 13.5V, 6.4F, SAS3 HBA

EBO

FRU

See "Servicing the Internal HBA Card and HBA Super Capacitor" in Oracle Exadata Storage Server X8-2 EF, HC, and XT Service Manual at http://docs.oracle.com/cd/E93361_01/html/E93395/gqtjv.html#scrolltoc

7315464

SAS-3 Data Cable Assembly

EBO

FRU

See "Servicing SAS Cables" in Oracle Exadata Storage Server X8-2 EF, HC, and XT Service Manual at http://docs.oracle.com/cd/E93361_01/html/E93395/gqthb.html#scrolltoc

7361253

M.2,240GB,SATA,22x80mm,SSD,INTEL, DC S4510

EBO

FRU

See "Servicing the Internal M.2 Flash SSDs" in Oracle Exadata Storage Server X8-2 EF, HC, and XT Service Manual at http://docs.oracle.com/cd/E93361_01/html/E93395/grlly.html#scrolltoc

7335943

6.4TB FLASH F640 NVMe AIC AURA 7

EBO

FRU

See "Servicing PCIe Cards" in Oracle Exadata Storage Server X8-2 EF, HC, and XT Service Manual at http://docs.oracle.com/cd/E93361_01/html/E93395/gqtcq.html#scrolltoc

7361454

6.4TB FLASH F640 V2 NVMe AIC AURA 8

EBO

FRU

See "Servicing PCIe Cards" in Oracle Exadata Storage Server X8-2 EF, HC, and XT Service Manual at http://docs.oracle.com/cd/E93361_01/html/E93395/gqtcq.html#scrolltoc

8200426

CPU INTEL CLX G5218 (B1) 2.3 GHz 125W 16c 4S 1TB (S-RF8T)

EBO

FRU

See "Servicing Processors" in Oracle Exadata Storage Server X8-2 EF, HC, and XT Service Manual at http://docs.oracle.com/cd/E93361_01/html/E93395/gqtmk.html#scrolltoc

7360978

Assembly, System board

EBO

FRU

See "Servicing the Motherboard Assembly" in Oracle Exadata Storage Server X8-2 EF, HC, and XT Service Manual at http://docs.oracle.com/cd/E93361_01/html/E93395/gqtwc.html#scrolltoc

7341466

Assembly, M.2 form factor riser

EBO

FRU

See "Servicing the Internal M.2 Flash SSDs" in Oracle Exadata Storage Server X8-2 EF, HC, and XT Service Manual at http://docs.oracle.com/cd/E93361_01/html/E93395/grlly.html#scrolltoc

Parts for Cisco Switch

Table 27-6 lists replaceable parts for the Cisco switch used with Recovery Appliance.

Note:

All replacement parts listed in the following table are FRUs when covered under Premier Support of Systems warranty.

Table 27-6 Replacement Parts for Cisco Switch

Part Number Description Repair Category Repair

7023685

Cisco Catalyst 4948 switch, RoHS:Y

IR

See chapter 3 in Catalyst 4948E and Catalyst 4948E-F Switch Installation Guide at http://www.cisco.com/c/en/us/td/docs/switches/lan/catalyst4900/4948E/installation/guide/4948E_ins.html

7024423

Power supply for Cisco Catalyst 4948 switch, RoHS:Y

HS

See chapter 4 in Catalyst 4948E and Catalyst 4948E-F Switch Installation Guide at http://www.cisco.com/c/en/us/td/docs/switches/lan/catalyst4900/4948E/installation/guide/4948E_ins.html

7024424

Cooling fan for Cisco Catalyst 4948 switch, RoHS:Y

HS

See chapter 4 in Catalyst 4948E and Catalyst 4948E-F Switch Installation Guide at http://www.cisco.com/c/en/us/td/docs/switches/lan/catalyst4900/4948E/installation/guide/4948E_ins.html

Parts for InfiniBand Switches

Table 27-7 lists the replaceable parts for the InfiniBand switches used in Recovery Appliance. See "Cables and Cable Accessories for Recovery Appliance" for information about InfiniBand cables.

Note:

All replacement parts listed in the following table are FRUs when covered under Premier Support of Systems warranty.

Table 27-7 Replacement Parts for InfiniBand Switches

Part Number Description Repair Category Repair

300-2143

760 watt power supply, RoHS:Y

HS

See Sun Datacenter InfiniBand Switch 36 User's Guide at

http://docs.oracle.com/cd/E19197-01/835-0784-05/gentextid-226.html

300-2299

760 watt AC input power supply

HS

See Sun Datacenter InfiniBand Switch 36 User's Guide at

http://docs.oracle.com/cd/E19197-01/835-0784-05/gentextid-226.html

350-1312

Fan module for Sun Datacenter InfiniBand Switch 36, RoHS:Y

HS

See Sun Datacenter InfiniBand Switch 36 User's Guide at

http://docs.oracle.com/cd/E19197-01/835-0784-05/gentextid-226.html

350-1566

Fan module, 1 RU, Sanace, reverse

HS

See Sun Datacenter InfiniBand Switch 36 User's Guide at

http://docs.oracle.com/cd/E19197-01/835-0784-05/gentextid-226.html

371-2210

CR2032 3 v battery, RoHS:Y

IR

See Sun Datacenter InfiniBand Switch 36 User's Guide at

http://docs.oracle.com/cd/E19197-01/835-0784-05/gentextid-226.html

541-3495

Sun Datacenter InfiniBand Switch 36, RoHS:YL

IR

See Sun Datacenter InfiniBand Switch 36 User's Guide at

http://docs.oracle.com/cd/E19197-01/835-0784-05/gentextid-226.html

7052970

Sun Datacenter InfiniBand Switch 36, RoHS:YL

IR

See Sun Datacenter InfiniBand Switch 36 User's Guide at

http://docs.oracle.com/cd/E19197-01/835-0784-05/gentextid-226.html

7061031

Fan module, 1 RU, Sanace, reverse

HS

See Sun Datacenter InfiniBand Switch 36 User's Guide at

http://docs.oracle.com/cd/E19197-01/835-0784-05/gentextid-226.html

Parts for Power Distribution Units

Table 27-8 lists the replacement parts for the power distribution units (PDUs). Given the number of cables and connections, Oracle recommends that you shut down the Recovery Appliance rack when replacing power distribution unit parts.

Note:

All replacement parts listed in the following table are FRUs when covered under Premier Support of Systems warranty.

Table 27-8 Replacement Parts for Power Distribution Units

Part Number Description Repair Category Repair

180-2379

13A/250V 90 degree IEC 320 Sheet E to IEC 320 C13 cord, 1 meter, RoHS:Y

HS

Not applicable

180-2380

13A/250V 90 degree IEC 320 Sheet E to IEC 320 C13 cord, 2 meter, RoHS:Y

HS

Not applicable

371-4000

Three-phase PDU: 15kV,5-Pin, IEC309 32A, 5 PIN 230/400V, 3ph IP44, International, RoHS:Y

IR

See "Replacing a Power Distribution Unit" of this guide.

371-4199

Single-phase PDU: 15kVA, with three 30A/250V 2-Pole/3-Wire NEMA L6-30P Plugs, North America, RoHS:Y

IR

See "Replacing a Power Distribution Unit" of this guide.

371-4201

Single-phase PDU: 15kVA, with three Blue 32A/240V Splash-proof 2-Pole/3-Wire IEC 60309 Plugs, International, RoHS:Y

IR

See "Replacing a Power Distribution Unit" of this guide.

371-5039

Single-phase PDU: 22k VA Hubbell CS8265C PlugNo X-Option

IR

See "Replacing a Power Distribution Unit" of this guide.

371-5040

Single-phase PDU: 22k VA Blue 32A IEC 60309 Plug No X-Option

IR

See "Replacing a Power Distribution Unit" of this guide.

7051908

Three-phase PDU: 15kVA, IEC309 60A, 4 PIN, 250VAC, 3ph IP67, North America, RoHS:Y

IR

See "Replacing a Power Distribution Unit" of this guide.

Cables and Cable Accessories for Recovery Appliance

Table 27-9 lists the replacement cables and cable accessories for Recovery Appliance.

Note:

All replacement parts listed in the following table are FRUs when covered under Premier Support of Systems warranty.

Table 27-9 Replacement Cables for Recovery Appliance

Part Number Description Repair Category Repair

350-1287

Slim rail, CMA, 1U-2U for a storage server

EBO

  1. If the server is currently running, then it should be shut down gracefully. See "Powering On and Off a Recovery Appliance Rack" for additional information.

  2. See "Installing the Cable Management Arm" in Sun Fire X4170, X4270, and X4275 Servers Installation Manual at

    http://docs.oracle.com/cd/E19477-01/820-5827-13/rack_install.html#50614309_99582

350-1546

Cable management arm (CMA) 1U, RoHS:Y for compute server

DBO

  1. If the server is currently running, then it should be shut down gracefully. See "Powering On and Off a Recovery Appliance Rack" for additional information.

  2. See "Installing the Cable Management Arm" in Sun Fire X4170, X4270, and X4275 Servers Installation Manual at

    http://docs.oracle.com/cd/E19477-01/820-5827-13/rack_install.html#50614309_99582

350-1519

Serial cable kit, RoHS:Y with the following:

  • USB to DB 9-pin M serial cable

  • DB 9-pin F to DB 9-pin F null modem cable

HS

See Sun Datacenter InfiniBand Switch 36 User's Guide at

http://docs.oracle.com/cd/E19197-01/835-0784-05/gentextid-226.html

350-1637

Label assembly, EV2, 2-way, upgrade, label

HS

See In-Rack Cabling Tables for Recovery Appliance X4

350-1638

Label assembly EV2, 3-way, service upgrade, label

HS

See In-Rack Cabling Tables for Recovery Appliance X4

350-1639

Label assembly EV2, 4-way, service upgrade, label

HS

See In-Rack Cabling Tables for Recovery Appliance X4

350-1640

Label assembly EV2, 5-way, service upgrade, label

HS

See In-Rack Cabling Tables for Recovery Appliance X4

350-1641

Label assembly EV2, 6-way, service upgrade, label

HS

See In-Rack Cabling Tables for Recovery Appliance X4

350-1642

Label assembly EV2, 7-way, service upgrade, label

HS

See In-Rack Cabling Tables for Recovery Appliance X4

350-1643

Label assembly EV2, 8-way, service upgrade, label

HS

See In-Rack Cabling Tables for Recovery Appliance X4

530-4445

QSFP InfiniBand passive copper cable, 10 GbE, 3 m, RoHS:Y

HS

See Sun Datacenter InfiniBand Switch 36 User's Guide at

http://docs.oracle.com/cd/E19197-01/835-0784-05/gentextid-226.html

Note: There is a loss of redundancy when replacing cables.

530-4446

QSFP InfiniBand passive copper cable, 10 GbE, 5 m, RoHS:Y

HS

See Sun Datacenter InfiniBand Switch 36 User's Guide at

http://docs.oracle.com/cd/E19197-01/835-0784-05/gentextid-226.html

Note: There is a loss of redundancy when replacing cables.

530-4403

4x QSFP copper QDR InfiniBand cable, 2 m, RoHS:Y

HS

See Sun Datacenter InfiniBand Switch 36 User's Guide at

http://docs.oracle.com/cd/E19197-01/835-0784-05/gentextid-226.html

Note: There is a loss of redundancy when replacing cables.

530-4404

4x QSFP copper QDR InfiniBand cable, 3 m, RoHS:Y

HS

See Sun Datacenter InfiniBand Switch 36 User's Guide at

http://docs.oracle.com/cd/E19197-01/835-0784-05/gentextid-226.html

530-4415

4x QSFP copper QDR InfiniBand cable, 5 m, RoHS:Y

HS

See Sun Datacenter InfiniBand Switch 36 User's Guide at

http://docs.oracle.com/cd/E19197-01/835-0784-05/gentextid-226.html

530-4432

Ethernet cable, Cat 5/5E, RJ45 to RJ45, 7 foot, blue, RoHS:Y

HS

See Catalyst 4948E and Catalyst 4948E-F Switch Installation Guide at http://www.cisco.com/c/en/us/td/docs/switches/lan/catalyst4900/4948E/installation/guide/4948E_ins.html

530-4433

Ethernet cable, Cat 5/5E, RJ45 to RJ45, 10 foot, red, RoHS:Y

HS

See Catalyst 4948E and Catalyst 4948E-F Switch Installation Guide at http://www.cisco.com/c/en/us/td/docs/switches/lan/catalyst4900/4948E/installation/guide/4948E_ins.html

530-4434

Ethernet cable, Cat 5/5E, RJ45 to RJ45, 7 foot, red, RoHS:Y

HS

See Catalyst 4948E and Catalyst 4948E-F Switch Installation Guide at http://www.cisco.com/c/en/us/td/docs/switches/lan/catalyst4900/4948E/installation/guide/4948E_ins.html

530-4435

Ethernet cable, Cat 5/5E, RJ45 to RJ45, 10 foot, black, RoHS:Y

HS

See Catalyst 4948E and Catalyst 4948E-F Switch Installation Guide at http://www.cisco.com/c/en/us/td/docs/switches/lan/catalyst4900/4948E/installation/guide/4948E_ins.html

530-4436

Ethernet cable, Cat 5/5E, RJ45 to RJ45, 7 foot, black, RoHS:Y

HS

See Catalyst 4948E and Catalyst 4948E-F Switch Installation Guide at http://www.cisco.com/c/en/us/td/docs/switches/lan/catalyst4900/4948E/installation/guide/4948E_ins.html

530-4437

Ethernet cable, Cat 5/5E, RJ45 to RJ45, 7 foot, orange, RoHS:Y

HS

See Catalyst 4948E and Catalyst 4948E-F Switch Installation Guide at http://www.cisco.com/c/en/us/td/docs/switches/lan/catalyst4900/4948E/installation/guide/4948E_ins.html

530-4438

Ethernet cable, Cat 5/5E, RJ45 to RJ45, 10 foot, black, RoHS:Y

HS

See Catalyst 4948E and Catalyst 4948E-F Switch Installation Guide at http://www.cisco.com/c/en/us/td/docs/switches/lan/catalyst4900/4948E/installation/guide/4948E_ins.html

530-4444

QSFP to QSFP Passive Copper Cable, 1 m, RoHS:Y

HS

See Sun Datacenter InfiniBand Switch 36 User's Guide at

http://docs.oracle.com/cd/E19197-01/835-0784-05/gentextid-226.html

530-4445

QSFP passive copper cable, 10 GE, 3 m

HS

See Sun Datacenter InfiniBand Switch 36 User's Guide at

http://docs.oracle.com/cd/E19197-01/835-0784-05/gentextid-226.html

530-4502-01

Ethernet cable, Cat 5/5E, 10 foot, blue, RoHS:Y

HS

See Catalyst 4948E and Catalyst 4948E-F Switch Installation Guide at http://www.cisco.com/c/en/us/td/docs/switches/lan/catalyst4900/4948E/installation/guide/4948E_ins.html

7015400

Power cable, jumper, SR2, 2m C14RA, 10A, C13

HS

See "Replacing a Power Distribution Unit" of this guide.

7042273

Slim rail, cable management arm, 1U-2U for a storage server

EBO

  1. If the server is currently running, then shut it down. See "Shutting Down Recovery Appliance".

  2. See "Installing the Second-Generation Cable Management Arm" in Sun Server X4-2L Service Manual at

    http://docs.oracle.com/cd/E36974_01/html/E38145/z40000151427029.html#scrolltoc

7102869

Passive fiber InfiniBand cable, 10 m, RoHS:Y

HS

  1. See Sun Datacenter InfiniBand Switch 36 User's Guide at

    http://docs.oracle.com/cd/E19197-01/835-0784-05/gentextid-226.html

Note: Purchase two QSFP SR Transceivers (Part Number X2124A-N) for each passive fiber cable.

7102870

Passive fiber InfiniBand cable, 20 m, RoHS:Y

HS

See Sun Datacenter InfiniBand Switch 36 User's Guide at

http://docs.oracle.com/cd/E19197-01/835-0784-05/gentextid-226.html

Note: Purchase two QSFP SR Transceivers (Part Number X2124A-N) for each passive fiber cable.

7102871

Passive fiber InfiniBand cable, 50 m, RoHS:Y

HS

See Sun Datacenter InfiniBand Switch 36 User's Guide at

http://docs.oracle.com/cd/E19197-01/835-0784-05/gentextid-226.html

Note: Purchase two QSFP SR Transceivers (Part Number X2124A-N) for each passive fiber cable.