5 Configuring the Rated Event Infranet.properties Files
Learn how to configure the Oracle Communications Billing and Revenue Management (BRM) Rated Event Loader (RE Loader) and the Kafka Event Streaming Infranet.properties files.
The RE Loader Infranet.properties file applies to the original processing method for either Oracle Communications Elastic Charging Engine (ECE) or Pipeline Manager, while the Event Streaming Infranet.properties file applies to the JSON streaming mode, which is only for ECE. See "Methods of Transferring Rated Events to BRM" for information about the processing methods.
Topics in this chapter:
Configuring the RE Loader Infranet.properties File
To configure RE Loader, you edit the RE Loader Infranet.properties file.
The Infranet.properties file contains configuration information for processing CDR files, such as the location of the RE Loader processing directory, how to connect to the BRM database, and how to process specific events.
Note:
In ECE, some parameters have values that are used by the code if the corresponding values are removed or commented out from the infranet.properties file. If these values are different from the default values in the file, they are mentioned in the tables below.
The tables in this chapter provide information for configuring the infranet.properties file for both ECE and Pipeline Manager.
To configure your RE Loader Infranet.properties file:
-
Open the BRM_home/apps/pin_rel/Infranet.properties file in a text editor.
-
Edit the file.
-
Save and close the file.
-
If you are using the RE Loader daemon, use the pin_ctl utility to run the BRM_home/bin/start_rel_daemon script. See "Running the pin_ctl Utility" in BRM System Administrator's Guide.
Topics in this section:
BRM Database Connection
Table 5-1 contains the RE Loader Infranet.properties file entries for connecting to the BRM database.
Table 5-1 Database Connection Entries
| Entry | Description |
|---|---|
|
infranet.rel.dbtype |
Specifies the BRM database type. If not included in the file, ECE uses the value ORACLE. The default value is oracle. |
|
infranet.rel.dbname |
Specifies the BRM database name. Note: Your database name is the TNSNAMES alias in the Oracle_home/network/admin/tnsnames.ora file. Ensure that this value is correct for your system. The default value is pindb. |
|
infranet.rel.userid |
Specifies the user ID for connecting to the BRM database. Ensure that this value is correct for your system. The default value is pin. |
|
infranet.rel.dbhost |
Specifies the database machine's host name. The default value is localhost. |
|
infranet.rel.dbport |
Specifies the database port number. The default value is 1433. |
|
infranet.rel.partition_set_number |
Specifies the partition set number, from 1 through 7. This entry applies only to BRM databases with multiple delayed partition sets.
The default value is 1. |
BRM Server Connection
Table 5-2 contains the RE Loader Infranet.properties file entries for connecting to the BRM server.
Table 5-2 BRM Server Connection Entries
| Entry | Description |
|---|---|
|
infranet.login.type |
Specifies whether RE Loader requires a login name and password to log in to BRM.
The default value is 1. |
|
infranet.failover |
In high-availability systems, specifies the secondary CM connection. For example: infranet.failover.1 = pcp://root.0.0.0.db_no:password@failover_host:failover_port/service/pcm_client There is no default value for this parameter. |
|
infranet.rel.polling_interval |
Specifies the interval, in milliseconds, that RE Loader checks the database to see whether another process is loading. The polling interval depends on the number and size of your input files. If you have very large files, make the polling interval longer. If you have many small files, make the interval shorter. The default value is 1000. |
|
infranet.rel.polling_time_out |
Specifies the time, in milliseconds, that RE Loader waits to load events before exiting. The time-out period depends on the number and size of your input files and how many parallel RE Loader processes are running. If you have very large files or many processes, make the time-out period longer. The default value is 600000. |
|
infranet.rel.updater_threads |
Specifies the number of threads dedicated to the update and preupdate stored procedures. You can specify a fixed number of threads or configure RE Loader to adjust the number of threads based on the number of database objects to update. To specify a fixed number of threads, set the entry equal to the desired number of threads. To configure RE Loader to automatically adjust the number of threads, set the entry to 0. In this case, RE Loader spawns the following number of threads:
Note: Specifying a number of threads that exceeds the number of CPUs in your system may cause deadlock due to a lack of system resources. If you set the infranet.rel.updater_threads entry to a value greater than 8, RE Loader returns a warning message and continues processing. If not included in the file, ECE uses the value 1. The default value is 4. |
|
infranet.rel.validate_dbnumber |
Specifies whether RE Loader performs an extra validation step to ensure that it is loading a call detail record (CDR) file into the correct database schema. Important: Use this option only for debugging. In a production environment, set this to false. Setting it to true degrades performance while loading data into the database. See "Turning Off Database Verification to Improve Processing Performance". The default value is true. |
|
infranet.rel.validate_indexes |
Specifies whether RE Loader verifies that the database indexes are correct before loading data into the database. Important: Use this option only for debugging. In a production environment, set this to false. Setting it to true degrades performance while loading data into the database. See "Turning Off Index Verification to Improve Database Loading Performance". If not included in the file, ECE uses the value true. The default value is false. |
|
infranet.rel.max_increment_by |
Specifies the number of database schemas in your system. This value is used by the POID generation algorithm to ensure that POIDs are unique across all database schemas in your system. See "Preventing POID Errors in Multischema Systems". The default value is 20. |
|
infranet.rel.sort.limit |
Defines the maximum number of CDRs that the preprocessing script can sort by account ID. This improves performance later during the balance updating process. If the number of CDRs in the input file is greater than the infranet.rel.sort.limit value, the preprocessing script does not sort the CDRs. If not included in the file, ECE uses the value 500000. The default value is 100000. |
RE Loader Daemon
Table 5-3 contains the RE Loader Infranet.properties file entries for running the RE Loader daemon.
Table 5-3 RE Loader Daemon Entries
| Entry | Description |
|---|---|
|
batch.check.interval |
Specifies the time interval, in seconds, to monitor files from the output directory. There is no default value for this parameter. |
|
batch.file.rename.extension |
Specifies the file name extension that the RE Loader daemon uses to rename the interim files before processing them. The default value is .bc. |
|
batch.start.highload.time |
Specifies the start time of your system's busiest period. Specify the hour, minute, and second, in hhmmss format, using the 24-hour clock. There is no default value for this parameter. |
|
batch.end.highload.time |
Specifies the start time of your system's slowest period. Specify the hour, minute, and second, in hhmmss format, using the 24-hour clock. There is no default value for this parameter. |
|
batch.lock.socket.addr |
Specifies the port address of the process. The default value is 24507. |
|
batch.rel.archiveDir |
Specifies the full path to the directory where a successfully processed file is archived. This is the default archive directory for all the event handlers. The default value is BRM_home/apps/pin_rel/gsm/tel/archive. |
|
batch.rel.rejectDir |
Specifies the full path to the directory where an unsuccessfully processed file is stored. This is the default reject directory for all the event handlers. The default value is BRM_home/apps/pin_rel/gsm/tel/archive. |
|
batch.random.events |
Specifies the name of the event type to process. If you have two or more types of events, separate each with a comma, but no blank space. For example, TEL,SMS,GPRS. There is no default value for this parameter. |
|
event.max.at.highload.time |
Specifies the highest number of the RE Loader threads permitted to run simultaneously for this event during the high-load time (that is, from batch.start.highload.time to batch.end.highload.time). For example, if event.max.at.highload.time is 2, two threads are permitted to run simultaneously for this event during the high-load time. There is no default value for this parameter. |
|
event.max.at.lowload.time |
Specifies the highest number of the RE Loader threads permitted to run simultaneously for this event during the low-load time (that is, from batch.end.highload.time to batch.start.highload.time). For example, if event.max.at.lowload.time is 2, two threads are permitted to run simultaneously for this event during the low-load time. There is no default value for this parameter. |
|
event.file.location |
Specifies the full path name of the directory to monitor for the arrival of new files that match the pattern in event.file.pattern. There is no default value for this parameter. |
|
event.file.pattern |
Specifies the file name pattern to look for. You can use an asterisk (*) to represent zero or more characters in the file name. No other wildcards are supported. There is no default value for this parameter. |
|
event.archiveDir |
(Optional) Specifies the full path to the directory where a successfully processed file is archived for a particular event handler. When multiple event handlers are configured, configure this entry to specify the directory that archives files from a particular event handler. There is no default value for this parameter. If it is not provided, the files are placed in the BRM_home/apps/pin_rel directory. |
|
event.rejectDir |
(Optional) Specifies the full path to the directory where an unsuccessfully processed file is stored for a particular event handler. When multiple event handlers are configured, configure this entry to specify the directory that stores files from a particular event handler. There is no default value for this parameter. If it is not provided, the files are placed in the BRM_home/apps/pin_rel directory. |
|
event.file.type |
Specifies the type of input CDR file.
The default is STANDARD. Always use STANDARD for Pipeline Manager. Note: You cannot specify both ECE_PRE_SPLIT and STANDARD in the same Infranet.properties file. |
Default RE Loader Processing
Table 5-4 contains the RE Loader Infranet.properties file entries for configuring the default processing of CDRs. The configuration information in this section applies to all events except for those defined in the storable class-specific section.
Table 5-4 Default Configuration Entries
| Entry | Description |
|---|---|
|
infranet.rel.default.interim_directory |
Specifies the RE Loader processing directory. This is the location where RE Formatter loads the CDR files. If not included in the file, ECE uses the value ./. The default value is BRM_home/apps/pin_rel. |
|
infranet.rel.default.supported_creation_processes |
Specifies which creation processes are supported. As initially configured, RE Loader supports all creation processes:
By default, RE Loader supports all creation processes. |
|
infranet.rel.default.failure_script |
Specifies the script called when RE Loader attempts to reload events that previously failed to load into the database. The default value is pin_rel_handle_interim_files.pl. |
|
infranet.rel.default.failure_flags |
Specifies the flag passed to the failure script. You can specify the following flags in the default pin_rel_handle_interim_files.pl failure script:
The initial value and the default are 1. |
|
infranet.rel.default.preprocess_script |
Specifies the name of the preprocessing script. The default value is pin_rel_preprocess_cdr.pl. |
|
infranet.rel.default.preprocess_flags |
Specifies the flag passed to the preprocessing script. The default value is 0. |
|
infranet.rel.default.load_util |
Specifies the name of the load utility. For Oracle's SQL Loader, it also specifies whether the utility uses direct-path loading or conventional-path loading:
To specify the load utility name and loading mode:
|
|
infranet.rel.default.preupdater_sproc |
Specifies the name of the preupdate stored procedure. The default value is pin_rel.pin_rel_pre_updater_sp. |
|
infranet.rel.default.preupdater_batch_size |
Specifies the size of the preupdate batch. The default value is 5. |
|
infranet.rel.default.preupdater_flags |
Specifies the flag passed to the preupdate stored procedure. The default value is 1. |
|
infranet.rel.default.updater_sproc |
Specifies the name of the update stored procedure. The default value is pin_rel.pin_rel_updater_sp. |
|
infranet.rel.default.updater_batch_size |
Specifies the size of the update batch. The default value is 5. |
|
infranet.rel.default.updater_flags |
Specifies the flag passed to the update stored procedure. The default value is 1. |
|
infranet.rel.default.success_script |
Specifies the script called when RE Loader successfully loads a batch of events into the BRM database. The default value is pin_rel_handle_interim_files.pl. |
|
infranet.rel.default.success_flags |
Specifies the flag passed to the success script. You can specify the following flags in the default pin_rel_handle_interim_files.pl script:
The default value is 2. |
|
infranet.rel.default.storable_class |
Specifies the storable class you are loading. Important: If you use Oracle SQL Loader, use the APPEND option in your RE Loader control files. Do not use the TRUNCATE option. If not included in the file, ECE uses the value /event/delayed/session/gprs. There is no default value for this parameter. |
|
infranet.rel.default.creation_process |
Specifies whether the file contains prerated, rerated, or discount events:
Important: RE Loader can dynamically source the creation process from the event record header file. Remove the comment from this entry only if all of your event record files come from the same creation process. |
|
infranet.rel.default.ece_control_file_directory |
Specifies the location of the control files generated by BRM Elastic Charging Engine (ECE). The default is BRM_home/apps/pin_rel. This parameter is not applicable to Pipeline Manager. |
|
infranet.rel.default.ece_data_file_directory |
Specifies the location of the data files generated by ECE. The default is BRM_home/apps/pin_rel. This parameter is not applicable to Pipeline Manager. |
|
infranet.rel.ece_preprocessed |
Specifies whether RE Loader uses ECE generated preprocessed control files and data files:
The default is FALSE. This parameter should always be FALSE for Pipeline Manager. |
Loading Event Records
Table 5-5 contains the RE Loader Infranet.properties file entries for configuring how RE Loader handles event records.
Table 5-5 RE Loader Event Handling Configuration Entries
| Entry | Description |
|---|---|
|
infranet.rel.use_end_time |
Specifies whether RE Loader uses the start time or end time of the rated event for deciding the billing cycle.
|
|
infranet.rel.default.header.record_type |
Specifies the header record type. The initial value and the default are 010. |
|
infranet.rel.default.detail.record_type |
Specifies the detail record type. The initial value and the default are 020. |
|
infranet.rel.default.trailer.record_type |
Specifies the trailer record type. The initial value and the default are 090. |
|
infranet.rel.field.delimiter |
Specifies the delimiter symbol. The initial value and the default are \t for tabs. |
|
infranet.rel.header.position.storable_class |
Specifies which field in the event record file contains the storable class name. The initial value and the default are 20. Note: When you set this field to 0, RE Loader uses the default storable class specified in infranet.rel.default.storable_class. |
|
infranet.rel.header.position.creation_process |
Specifies which field in the event record file contains the name of the creation process (for example, whether the file contains prerated, rerated, or discount events). The initial value and the default are 18. Note: You can specify 0 if you do not need this field validated. |
|
infranet.rel.header.position.sender |
Specifies which field in the event record file contains the sender. The initial value and the default are 3. |
|
infranet.rel.header.position.recipient |
Specifies which field in the event record file contains the recipient. The initial value and the default are 4. |
|
infranet.rel.header.position.file_sequence |
Specifies which field in the event record file contains the file sequence number. The initial value and the default are 5. Note: You can specify 0 if you do not need this field validated. |
|
infranet.rel.header.position.creation_timestamp |
Specifies which field in the event record file contains the creation time stamp. The initial value and the default are 7. Note: You can specify 0 if you do not need this field validated. |
|
infranet.rel.trailer.position.record_count |
Specifies the field position of the field that contains the total number of detail records in the output file. The initial value and the default are 7. The field position starts with 1. |
|
infranet.rel.file_extension.disc.transform_script |
By default, this entry is commented out. The initial value is pin_rel_transform_cdr.pl. No default exists. |
|
infranet.rel.file_extension.disc.transform_flags |
By default, this entry is commented out. The initial value is 0. No default exists. |
|
infranet.rel.header.position.object_cache_type |
Set this value to 0. The default value is 23. This parameter is not applicable to ECE. |
Storable-Class RE Loader Processing
Table 5-6 contains the RE Loader Infranet.properties file entries for configuring CDR processing for specific storable classes.
For each storable class, only the infranet.rel.storable_class.classname.number_of_tables and infranet.rel.storable_class.classname.table.N.name entries are mandatory. RE Loader uses the values from the related infranet.rel.default settings for any undefined storable class-specific entries.
When editing these entries:
-
Create a set of entries for each event you want to load.
-
Replace classname with the appropriate storable class name. For example, use event_delayed_session_gprs for the /event/delayed/session/gprs storable class.
-
Create a set of *.table.N.* entries for each table. For example, if the storable class contains three tables, create a set of *.table.1.* entries, a set of *.table.2.* entries, and a set of *.table.3.* entries.
Table 5-6 Storable-Class-Specific Configuration Entries
| Entry | Description |
|---|---|
|
infranet.rel.storable_class.classname.interim_directory |
RE Loader processing directory. This is the location where preprocessed events are temporarily stored before they are loaded. |
|
infranet.rel.storable_class.classname.supported_creation_processes |
Specifies whether the file contains prerated, rerated, or discount events. |
|
infranet.rel.storable_class.classname.failure_script |
Specifies the script to call when RE Loader attempts to load events that previously failed to load into the database. |
|
infranet.rel.storable_class.classname.failure_flags |
Specifies the flag to pass to the failure script. |
|
infranet.rel.storable_class.classname.preprocess_script |
Specifies the name of the preprocessing script. |
|
infranet.rel.storable_class.classname.preprocess_flags |
Specifies the flag to pass to the preprocessing script. |
|
infranet.rel.storable_class.classname.number_of_tables |
Specifies the number of tables in the storable class. Important: This entry is mandatory for all types of events. |
|
infranet.rel.storable_class.classname.table.N.name |
Specifies the name of a storable class table. Important: This entry is mandatory for all types of events. |
|
infranet.rel.storable_class.classname.table.N.load_util |
Specifies the name of the load utility. For Oracle's SQL Loader, it also specifies whether the utility uses direct-path loading or conventional-path loading:
Important: If you use conventional-path loading, use the APPEND option in your RE Loader control files. Do not use the TRUNCATE option. |
|
infranet.rel.storable_class.classname.table.N.control_file |
Specifies the control file to use when loading the data file into the database. |
|
infranet.rel.storable_class.classname.preupdater_sproc |
Specifies the name of the preupdater stored procedure. |
|
infranet.rel.storable_class.classname.preupdater_batch_size |
Specifies the preupdater batch size. |
|
infranet.rel.storable_class.classname.preupdater_flags |
Specifies the flag to pass to the preupdater stored procedure. |
|
infranet.rel.storable_class.classname.updater_sproc |
Specifies the name of the updater stored procedure. |
|
infranet.rel.storable_class.classname.updater_batch_size |
Specifies the updater batch size. |
|
infranet.rel.storable_class.classname.updater_flags |
Specifies the flag to pass to the updater stored procedure. |
|
infranet.rel.storable_class.classname.success_script |
Specifies the script to call when RE Loader successfully loads a data file into the BRM database. |
|
infranet.rel.storable_class.classname.success_flags |
Specifies the flag to pass to the success script when RE Loader successfully loads a data file into the BRM database. |
RE Loader Logging
Table 5-7 contains the RE Loader Infranet.properties file entries for configuring logging.
Table 5-7 RE Loader Logging Configuration Entries
| Entry | Description |
|---|---|
|
infranet.log.file |
Specifies the name of the RE Loader log file. The initial value is rel.pinlog. No default exists. |
|
infranet.log.name |
Specifies the name of the application. The initial value is REL for RE Loader. No default exists. |
|
infranet.log.level |
Specifies the log reporting level:
The initial value is 1. The default is String.valueOf(ErrorLog.Error) (equivalent to 1). See "Setting the Reporting Level for Logging Messages" in BRM System Administrator's Guide. |
|
infranet.log.logallebuf |
Specifies whether RE Loader automatically logs all EbufException errors. The initial value is true. No default exists. |
|
infranet.rel.custom_error_codes |
Specifies the name of the custom error code file. The initial value is CustomErrorCodes.properties. No default exists. To move this file from its default location, you must create a symbolic link between the name of the file and its new location. To create this link, go to the BRM_home/apps/pin_rel directory and enter the following at the command prompt: ln -s path_to_where_file_was_moved/CustomErrorCodes.properties ./CustomErrorCodes.properties |
Configuring the Event Stream Processor Infranet.properties File
This information applies only to ECE using the JSON streaming mode. See "Event Streaming Mode" for information about this processing method.
The tables in this section provide information for configuring the Infranet.properties file for event streaming.
To configure your Kafka Consumer Infranet.properties file:
-
Open the BRM_home/apps/event_stream_processor/Infranet.properties file in a text editor.
-
Edit the file.
-
Save and close the file.
The following topics are in this section:
Kafka Consumer Configuration
You can configure the parameters in this section to poll Kafka topics and pass the events in batches to the Event Stream Processor (ESP) for processing.
Note:
Parameters prefixed with kafka.config. pass directly to the Kafka consumer configuration.
Table 5-8 lists the parameters for polling Kafka topics and passing the event in batches.
Table 5-8 Kafka Consumer Entries
| Name | Default | Description |
|---|---|---|
|
kafka.config.auto.offset.reset |
earliest |
The value to use only when a consumer has no valid committed offset for a partition. Available values are:
|
|
kafka.config.bootstrap.servers |
${HOSTNAME}:9092 |
A list of host/port pairs to use for establishing the initial connection to the Kafka cluster. This list should be in the form: host1:port1,host2:port2,... |
|
kafka.config.enable.auto.commit |
false |
Specifies if the consumer's offset is periodically committed in the background. Note: This parameter is disabled for manual offset commits. |
|
kafka.config.key.deserializer |
org.apache.kafka.common.serialization.StringDeserializer |
The deserializer class for keys. |
|
kafka.config.value.deserializer |
org.apache.kafka.common.se rialization.ByteArrayDeserializer |
The deserializer class for values. |
|
kafka.config.max.poll.records |
5 |
The maximum number of records returned in a single poll. Note: Set max.poll.records to 1 when you enable batching in Rated Event Formatter. Also, ensure you set event_stream_processor.ref_batching_enabled to true. |
Kafka Consumer Availability and Batching Configuration
You can configure the parameters in this section to manage how the consumer connects to the Kafka broker and processes events in batches.
Table 5-9 lists the parameters for connecting to the Kafka broker and processing events in batches.
Table 5-9 Kafka Consumer Availability and Batching Entries
| Name | Default | Description |
|---|---|---|
|
kafka.server.check.retries |
5 |
The number of retry attempts to connect to the Kafka server if it is unreachable. |
|
kafka.server.check.timeout.ms |
10000 |
The timeout, in milliseconds, to wait for a response from the Kafka server for each attempt. |
|
kafka.server.offset.retry.delay.ms |
5000 |
The delay, in milliseconds, before retrying offset retrieval from the database when an error occurs during an offset fetch. |
|
kafka.server.poll.timeout.ms |
1000 |
The maximum time, in milliseconds, to wait for messages during each poll call. |
|
event_stream_processor.ref_batching_enabled |
false |
Specifies if streaming mode is enabled for internal event batch processing. |
Helidon Server Configuration
You can configure the parameters in this section to manage how the Helidon server binds to network interfaces and listens for incoming HTTP requests.
Table 5-10 lists the parameters for configuring the Helidon server’s network interface and port settings.
Table 5-10 Helidon Server Entries
| Name | Default | Description |
|---|---|---|
|
server.host |
${HOSTNAME} |
The network interface the server binds to. |
|
server.port |
8080 |
The port on which the Helidon server listens for incoming HTTP requests. |
Metrics Configuration
You can configure the parameters in this section to manage how the application monitors and collects metrics during operation.
Table 5-11 lists the parameters for configuring metric monitoring intervals and thread settings.
Table 5-11 Metric Entries
| Name | Default | Description |
|---|---|---|
|
metrics.monitor.retry.interval |
60 |
The interval, in seconds, for retrying metric monitoring operations. |
|
metrics.monitor.thread.name |
kafka-consumer-metrics-monitor |
The name of the thread that monitors Kafka consumer metrics. |
Topic Configuration
You can configure the topics for the ESP to consume events from Kafka.
Table 5-12 lists the parameters for configuring these event topics. Sequence determines the order in which the system consumes internal Kafka topics.
Table 5-12 Topic Entries
| Name | Default | Description |
|---|---|---|
|
event_stream_processor.topic.internal.sequence |
RatedEvents |
The name of the internal Kafka topic to be consumed. |
Handler Configuration
You can configure handler classes to process internal events.
Table 5-13 lists the parameters for configuring event handler classes responsible for handling various events. Sequence determines the order in which the system handles internal events.
Table 5-13 Handler Entries
| Name | Default | Description |
|---|---|---|
|
event_stream_processor.handler.default (Required) |
com.oracle.brm.event_stream_processor.handler.EventHandlerImpl |
The default event handler implementation. |
|
event_stream_processor.handler.internal.sequence |
com.oracle.brm.event_stream_processor.handler.InternalEventHandlerImpl |
The class for handling the Rated Event Formatter (REF) generated events. |
JDBC Connection Pool Configuration
You can configure the parameters to define how the event stream processor connects to the BRM database.
Table 5-14 lists the parameters available for configuring the JDBC connection pool for database connectivity.
Table 5-14 JDBC Connection Pool Entries
| Name | Default | Description |
|---|---|---|
|
event_stream_processor.jdbc_pool.connectionURL |
jdbc:oracle:thin:@//HOST:{PORT}/PINDB |
The connection URL for the BRM database. |
|
event_stream_processor.jdbc_pool.connectionWaitTimeout |
10 |
The maximum time, in seconds, to wait for a connection. |
|
event_stream_processor.jdbc_pool.fastConnectionFailoverEnabled |
false |
Specifies whether Fast Connection Failover (FCF) is enabled. |
|
event_stream_processor.jdbc_pool.initialPoolSize |
1 |
The initial number of connections to create in the pool. |
|
event_stream_processor.jdbc_pool.jmxEnabled |
true |
Specifies if UCP JMX metrics are enabled. |
|
event_stream_processor.jdbc_pool.maxPoolSize |
50 |
The maximum number of connections permitted in the pool at once. |
|
event_stream_processor.jdbc_pool.maxStatements |
50 |
The maximum number of database statements that can be cached. |
|
event_stream_processor.jdbc_pool.metricUpdateInterval |
10 |
The frequency, in seconds, for updating UCP metrics. |
|
event_stream_processor.jdbc_pool.minPoolSize |
1 |
The minimum number of connections maintained when idle. |
|
event_stream_processor.jdbc_pool.nonTransientErrorCodes |
1,1450,12899,1722,20010,1489,6550 |
The transient error codes. |
|
event_stream_processor.jdbc_pool.onsConfiguration |
No default value |
The Oracle Notification Services configuration for FCF. |
|
event_stream_processor.jdbc_pool.poolLogLevel |
INFO |
The initial log level for UCP logging. |
|
event_stream_processor.jdbc_pool.sqlForValidateConnection |
SELECT SYSDATE FROM DUAL |
The SQL command for validating database connections if enabled. |
|
event_stream_processor.jdbc_pool.user |
pin |
The BRM database user name. |
|
event_stream_processor.jdbc_pool.validateConnectionOnBorrow |
false |
Specifies if each connection is validated when retrieving from the pool. |
|
event_stream_processor.jdbc_pool.validateSchema |
true |
Specifies if the BRM schema is validated on pool creation. |
|
event_stream_processor.jdbc_pool.wallet_entry_name |
infranet.rel.password |
The wallet entry name for the database password. |
|
event_stream_processor.jdbc_pool.wallet_location |
${BRM_CONF_WALLET} |
The path to the BRM wallet for database. |
SSL DB Configuration
You can configure the parameters to specify how the event stream processor manages SSL settings for secure connections to the BRM database.
Table 5-15 lists the parameters for configuring SSL options in the JDBC connection pool.
Table 5-15 SSL DB Entries
| Name | Default | Description |
|---|---|---|
|
event_stream_processor.jdbc_pool.dbSSLClientAuth |
false |
Specifies if SSL client authentication is enabled. |
|
event_stream_processor.jdbc_pool.dbSSLEnabled |
false |
Specifies if SSL is enabled for database connections. |
|
event_stream_processor.jdbc_pool.sslKeyStoreLocation |
DB_SSL_KEYSTORE_LOC/cwallet.sso |
The path to the SSL key store. |
|
event_stream_processor.jdbc_pool.sslTrustStoreLocation |
DB_SSL_TRUSTSTORE_LOC/cwallet.sso |
The path to the SSL trust store. |
|
event_stream_processor.jdbc_pool.sslServerCertDN |
No default value |
The name of the SSL server certificate. |
|
event_stream_processor.partition_set |
1 |
The partition set number to use for delayed events. |
|
event_stream_processor.poid_increment_by |
5 |
The maximum allowed increment value for POID ranges. |