4.2 act-cdl
Use this command to initiate a command driven loopback for testing a signaling link.
Command Driven Loopback is the ability to locally drive a signaling link into a manual line loopback. The data received on the signaling link is echoed (transmitted) back. This is effectively the reverse of the tst-slk:loopback=lxvr
, which loops the transmitted data back to the receiver.
Parameters
- link (mandatory)
- SS7 signaling links. The SS7 signaling link to be tested.
- Synonym:
- port
- Range:
- a, b, a1 - a31, b1 - b31
Not all card types support all link parameter values.
See Table A-1 for valid link parameter range values for each type of card that can have assigned signaling links.
- loc (mandatory)
- The card location as stenciled on the shelf of the system.
- Range:
- 1101 - 1108, 1111 - 1112, 1201 - 1208, 1211 - 1218, 1301 - 1308, 1311 - 1318, 2101 - 2108, 2111 - 2118, 2201 - 2208, 2211 - 2218, 2301 - 2308, 2311 - 2318, 3101 - 3108, 3111 - 3118, 3201 - 3208, 3211 - 3218, 3301 - 3308, 3311 - 3318, 4101 - 4108, 4111 - 4118, 4201 - 4208, 4211 - 4218, 4301 - 4308, 4311 - 4318, 5101 - 5108, 5111 - 5118, 5201 - 5208, 5211 - 5218, 5301 - 5308, 5311 - 5318, 6101 - 6108, 6111 - 6118
Example
act-cdl:loc=1205:link=b
Dependencies
The card location specified in the loc parameter must be equipped.
The signaling link specified in the link parameter must be equipped.
LFS processing must be stopped or must be allowed to complete on the specified signaling link before this command can be entered.
The loopback=payload parameter is valid only for LIM-ATM and E1-ATM cards.
Command Driven Loopback testing is not available during upgrade.
A Command Driven Loopback test cannot be in progress on the specified link when this command is entered.
A tst-slk
command cannot be in progress on the specified link when this command is entered. The tst-slk
processing must be stopped or must be allowed to complete before this command can be entered
The card location specified in the loc parameter must be in the In-Service-Normal (IS-NR) state.
The card location specified in the loc parameter must support Command Driven Loopback testing.
The signaling link specified in the link parameter must not be active.
The card location specified in the loc parameter cannot be reserved by the system.
Notes
None
Output
act-cdl:loc=1205:link=b
tekelecstp 05-01-21 17:00:36 EST EAGLE5 33.0.0
Command Accepted: Command Driven Loopback message is sent.
;
tekelecstp 05-01-21 17:00:36 EST EAGLE5 33.0.0
Command Completed.
;